RXA R410AREVERSIBLE AIR-WATER HEAT PUMPSReversible heat pump (IP)or only cooling unit (IR)operating on R 410A ecological gasHigh efficiencyDOZONE SAVEThe unit is available in the following version:- Basic version (VB)- Pump version (VP)- Storage tank and pump version (VA)- Storage tank and additional electrical heater (VA+REL)IR cooling only units MU 6.1 7.1 9.1 9.1/3 11.1 11.1/3 14.1 17.1Cooling capacity (*) (E) kW 6,2 7,4 9,4 9,4 10,8 10,8 13,8 17,3Power input in cooling mode (*) (E) kW 2,15 2,85 3,7 3,7 4,15 4,15 5,15 6,65IP heat pump units MU 6.1 7.1 9.1 9.1/3 11.1 11.1/3 14.1 17.1Cooling capacity (*) (E) kW 6,0 7,1 9,2 9,2 10,6 10,6 13,6 17,1Power input in cooling mode (*) (E) kW 2,15 2,85 3,7 3,7 4,15 4,15 5,15 6,65Heating capacity (**) (E) kW 7,0 8,2 10,4 10,4 11,5 11,5 15,3 18,6Power input in heating mode (**) (E) kW 2,25 2,75 3,65 3,65 4,05 4,05 4,95 6,4NOTE:(*) Data refers to: Water temperature: inlet: 12°C - outlet: 7°C, Outside <strong>air</strong> temperature 35°C DB(**) Data refers to: Water temperature: inlet: 40°C - outlet: 45°C, Outside <strong>air</strong> temperature 7°C DB, humidity 87%(E) EUROVENT certified dataRMA WATER CHILLERS WITH AXIAL FANSCooling only chiller (IR) or heat pump (IP)operating on R410A ecological gas.DOZONE SAVEThe unit is available in the following versions:- Basic configuration (AB)- Low-noise kitOn request:- Copper condenser fins- Coated aluminium fins- Tinned copper fins- Cataphoresis paintingIR cooling only units, basic configuration AB - 0M5 MU 19 22 26 30 40 51Cooling capacity (*) (E) kW 19,2 22,3 26,0 29,1 40,8 51,7Total power input in cooling mode (*) (E) kW 7,05 7,75 8,90 10,3 13,1 17,9IP heat pump units, basic configuration AB - 0M5 MU 19 22 26 30 40 51Cooling capacity (*) kW 18,7 21,9 25,6 28,2 39,1 49,7Total power input in cooling mode (*) (E) kW 6,9 7,75 8,8 10,1 12,7 17,7Heating capacity (**) (E) kW 20,4 23,5 27,6 29,4 41,0 51,3Total power input in heating mode (**) (E) kW 6,95 7,75 9,05 9,8 13,1 16,8NOTE:(*) Data refers to: Water temperature: inlet: 12°C - outlet: 7°C, Outside <strong>air</strong> temperature 35°C DB(**) Data refers to: Water temperature: inlet: 40°C - outlet: 45°C, Outside <strong>air</strong> temperature 7°C DB, humidity 87%(E) EUROVENT certified data- 6 -
RGA WATER CHILLERS WITH AXIAL FANSCooling only chiller (IR) or heat pump(IP), operating on R410A ecologicalgas, VB version. Built-in storage tank(optional) 200 or 400 litres.DOZONE SAVEThe unit is available in the following versions:- Basic configuration (AB)- Low-noise kit (AS)- Extra low-noise unit (ASS)- Special version with desuperheater (VD)- Special version for the production of low temperature brine (VI)On request:- Copper condenser fins- Coated aluminium fins- Tinned copper fins- Cataphoresis paintingIR cooling only units, basic config. AB - 0M5 MU 50 60 70 80 90 100 115 130 145 160Cooling capacity (*) (E) kW 53,5 58,6 68,8 78,7 91,0 102,0 112,0 126,0 143,0 158,0Total power input in cooling mode (*) (E) kW 18,1 20,3 22,7 27,4 31,8 35,2 39,1 44,1 51,4 56,4IP heat pump units, basic config. AB - 0M5 MU 50 60 70 80 90 100 115 130 145 160Cooling capacity (*) kW 52,9 57,5 67,2 74,1 89,2 99,0 110,0 122,0 138,0 154,0Total power input in cooling mode (*) (E) kW 18,0 20,2 22,5 26,5 31,6 35,0 39,0 43,6 51,2 55,9Heating capacity (**) kW 53,2 58,0 67,7 76,2 91,4 103,0 113,0 125,0 143,0 156,0Total power input in heating mode (**) (E) kW 18,0 19,8 22,1 24,9 31,8 35,0 38,4 42,6 50,5 55,2NOTE:(*) Data refers to: Water temperature: inlet: 12°C - outlet: 7°C, Outside <strong>air</strong> temperature 35°C DB(**) Data refers to: Water temperature: inlet: 40°C - outlet: 45°C, Outside <strong>air</strong> temperature 7°C DB, humidity 87%(E) EUROVENT certified dataRLAWATER CHILLERS WITH AXIAL FANSCooling only chiller or heat pump, operatingon R407C ecological gas, VB version.Built-in storage tank (optional).R407CDOZONE SAVEThe unit is available in the following versions:- Basic configuration (AB)- Low-noise configuration (AS)- Special version with desuperheater (VD)- Special version with partial heat recovery (VP)- Special version with total heat recovery (VR)- Special version for the production of low temperature brine (VI)On request:- Copper condenser fins- Coated aluminium fins- Tinned copper fins- Cataphoresis paintingIR cooling only units, basic config. AB - 7M5 MU 150 165 180 205 230 260 285 315Cooling capacity (*) (E) kW 149,0 163,0 178,0 205,0 229,0 255,0 284,0 313,0Total power input in cooling mode (*) (E) kW 62,9 67,9 72,1 81,0 90,2 102,0 115,0 126,0IP heat pump units, basic config. AB - 7M5 MU 150 165 180 205 230 260 285 315Cooling capacity (*) kW 136,0 150,0 165,0 193,0 215,0 238,0 275,0 301,0Total power input in cooling mode (*) (E) kW 60,4 66,5 71,7 81,1 92,3 102,0 114,0 124,0Heating capacity (**) kW 165,0 181,0 195,0 228,0 255,0 282,0 314,0 347,0Total power input in heating mode (**) (E) kW 62,8 67,5 70,9 80,0 87,9 99,7 109,0 120,0NOTE:(*) Data refers to: Water temperature: inlet: 12°C - outlet: 7°C, Outside <strong>air</strong> temperature 35°C DB(**) Data refers to: Water temperature: inlet: 40°C - outlet: 45°C, Outside <strong>air</strong> temperature 7°C DB, humidity 87%(E) EUROVENT certified data- 7 -