<strong>Smartpack2</strong> ControllerMonitoring and Control UnitSMARTPACK JUST GOT SMARTER• New and improved interface• New and improved functionality• Improved statistics• Full hybrid supportDistributed control system for medium to largepower systems.Product DescriptionNew features and look on a well-tested control platform<strong>Smartpack2</strong> is built on the proven software platform that isused in Smartpack, making it reliable and robust. Increasedprogram memory and new hardware allows for morefeatures and improved user interface. The new modulardistributed control system simplifies connections.ApplicationsMinimize fuel consumption for off grid sitesSites that run only on power from a generator often keep itrunning at a low load where most generators have lowefficiency. Adding cyclic batteries and a <strong>Smartpack2</strong>controlled power system, the <strong>Smartpack2</strong> will run thegenerator in cyclic operation at its maximum efficiency. Thiswill typically give a 55% reduction in fuel consumption. Thetotal OPEX will be further decreased as the generatorservice will be less frequent due to it not running 24hours aday.Hybrid telecom sites<strong>Smartpack2</strong> comes with advanced software to controlpower systems with multiple power sources. It handles solarenergy and generators in combination with unstable grid.<strong>Smartpack2</strong> is also prepared for wind power. It can beconfigured to automatically choose the smartest energysource at all times, and it can log the amount of energyproduced by the various sources.Simplifies operation in large multisite systems<strong>Smartpack2</strong> offers many offsite benefits if it is connected tothe internet. View the system status, change parametersand receive alarms at a multisite management center. Usefeatures such as battery lifetime estimations, fuelconsumption through tank level measurement andgenerator runtime, to plan for site service. Use the energylogs to document the amount of renewable energy used,and to plan for site upgrades.www.eltekvalere.comKey Features Graphical TFT high contrast, high resolution colordisplay for easy navigation in user menuLEDs for local visual alarms (Major, Minor, Power ON)Ethernet for remote or local monitoring and control viaWEB BrowserEthernet port with HP Auto MDI/MDI-X for detectionand correction for straight-through and crossovercables.SNMP protocol with TRAP, SET and GET on Ethernet.Email of TRAP alarms6 programmable relay outputs for “traditional” remotemonitoring. Expandable with I/O Monitor CAN Nodes.6 programmable multipurpose inputs (“digital inputs” oranalog signals). Expandable with I/O Monitor CANNodes.Comprehensive loggingBackup of critical control features in Basic unit.Automatic battery monitoring and testBattery lifetime indication Battery used and remaining capacity (Ah or %)monitoringUser defined alarm grouping (boolean logic for groupedalarms)Uploading and Downloading of configuration files withSD Card or PowerSuite (Windows application).SD card slot for downloading/uploading of logs andsetup Comprehensive generator/hybrid/DC solar systemcontrol and monitoring featuresSee last page for specifications


<strong>Smartpack2</strong> On-Site – display and menus for easyaccess to status and complete configuration.No PC to hook on to the controller – no problem! Key system status parameters displayed by default:alarms, battery voltage, rectifier current and loadcurrent.Single key-hit to display list of triggered alarms.All configurations and setup available from the menus.High resolution and contrast – excellent reading andable to show complex content.Multilanguage (changeable “on the fly”): English andpending languages: Chinese Simp., Chinese Trad.,Finish, French, German, Greek, Italian, Norwegian,Polish, Portuguese, Russian, Spanish, Swedish andTurkish.<strong>Smartpack2</strong> Remote – new web access WebPower5.0 Easy to use, more information and control.Through the internet or on-site directly from PC! System overview with status as “home page”.Graphs show changes over time of various systemvariables.Configure alarm limits and all other parameters throughself explanatory symbols and menus.Secure; access control and optional SSL.WebPower 5.0: new look and more functionality.Disable external alarms while servicing.Access control – pin code to change configuration.Setup data and logs – bring your SD card. Convenient storage – for backup and transportation.Easy and robust to roll out a set of systems withidentical setup.Event log: scroll through all events toget a quick overview of system history.System configuration: all parametersare editable from the menu.NetworkMain menu: easy task oriented layoutand self explanatory navigation.<strong>Smartpack2</strong> MasterLAN PortSD Card Reader for firmwareupgrades, complete setup storageand restore, and storage of logs.CAN BUS FOR POWER AND INTERNAL COMMUNICATIONwww.eltekvalere.com 2(4) <strong>242100.50X</strong>.<strong>DS</strong>3 – v2


New FPC Cabinet•New 4U distribution<strong>Smartpack2</strong> Master1. Photo Voltaic PanelsFlatpack2 HE Solar ChargerFlatpack2 HE Rectifiers2. Grid if available3. Generator control/tank level<strong>Smartpack2</strong> system building blocksThe <strong>Smartpack2</strong> Basic unitThree units are required to build a complete <strong>Smartpack2</strong> controlsystem.• <strong>Smartpack2</strong> Master is the master controller and visible partof the system.• <strong>Smartpack2</strong> Basic handles housekeeping.• IO Monitor Type2 handles external inputs and outputs.The system can be expanded with several Basic, I/O units andother CAN nodes in the Smartpack family, all connected via theCAN bus.<strong>Smartpack2</strong> Basic3 Temp probe or digital inputs.System inputs: System voltage,Battery Current, Load/Battery Fuse.3 LVD controls. Add more basicsfor more LVDs.Power connection to systemsDC output or battery.Sits inside the system – only available to servicepersonnel.Powers all control units attached to the CAN bus.Handles LVD control.Takes control of critical system function in case of aMaster Controller failure.Short of CAN power or LVD control – add more Basicunits.6 digital inputs (eg for fuse monitoring).6 Relay Outputs (eg for external alarms)I/O Monitor Type 2CAN BUS FOR POWER AND INTERNAL COMMUNICATIONCAN BUS TO OTHER MODULES LIKERECTIFIERS, SOLAR CHARGERS ANDOPTIONAL CONTROL UNITS.www.eltekvalere.com 3(4) <strong>242100.50X</strong>.<strong>DS</strong>3 – v2


<strong>Smartpack2</strong> Distributed Control SystemAdditional Technical SpecificationsControl FeaturesControl Systemo Output Voltage Measuremento Load Current Calculationo Energy Calculationo Load/Battery Disconnecto Real Time Clock with Battery Backupo Stored Site Text/ID and Messageso Position (long/lat) for auto placemento Test of Relay Outputso Alarm grouping of events for relay outputsBatteryo Battery Current Measuremento Battery Temperature Measuremento Battery Testing (acc. to discharge table or set time limit)o Setup of Battery Data/Tableo Battery Capacity Indicationo Battery Boost Chargingo Auto – Ah discharge or voltage thresholdo Interval or Manualo Temperature Compensated Chargingo Charge Current Limitationo Battery Low Voltage Disconnecto Temperature dependent (optional)o Mains independent (optional)Rectifiero Available information about each rectifier, e.g. serialnumber, version, internal temperatureo Individual Rectifier Current Measuremento Individual Rectifier Input Voltageo Efficiency Managemento Emergency Voltageo Startup delayo Detailed internal alarms summaryGeneratoro On/Off control for cyclic charging and fuel reductiono Start-up delay of power systemo Fuel consumption logging and alarming based on tank levelmeasuremento Discharge cycle counter/Generator run hour loggingo DoD [%] logging w/time stampAlarms / Events availableAlarms can be set up with monitoring of minor and major levels.Hysteresis and time delay is user configurable. All average and peaklevels on analogue values are auto loggedPower & Control Systemo AC Mains Low (2-level)o AC Phase Voltage x3 (2-level)o “Digital” Inputs (programmable descriptions)o Events trigger by inputsService mode (block relays), Generator running, Lower charge currentlimit, Battery test, Boost inhibit, Emergency low voltage , Clearmanual reset alarms.Loado Load Disconnecto Voltage or Timer (from mains failure) basedo Mains independent (optional)o Load Fuseo Load CurrentBatteryo Battery Voltage (4-level, optional 8-level)o Battery Temperature (2-level)o Battery Used Capacity (2-level) [Ah or %]o Battery Remaining Capacity (2-level) [Ah or %]o Battery Fuseo Symmetry Failure (2-level) – Only with BM Can Nodeo Battery Quality after test (2-level)o Battery Current (4-level)o Battery Life Time (2-level) [from temperature log]www.eltekvalere.comHeadquarters:Eltek ValereGråterudv. 8, PB 2340 Strømsø, 3003 Drammen, NorwayPhone: +47 32 20 32 00 Fax: +47 32 20 32 10Alarms / Events available (…continued)Rectifiero Rectifier Failure (2-level)o Rectifier Capacity (2-level)o Rectifier Current (2-level)o Rectifier Avg. Temperature (2-level)o Rectifier Current Share (2-level)Specifications – MasterPower Consumption Max 4.5WMTBFDisplayPorts/SlotsSNMPWebNetworkingData loggingDimensions(WxHxD)Specifications – BasicInput VoltageTemperature Range> 1 300 000 hours Telcordia SR-332Issue I, method III (a) (Tambient : 25°C)32k colour TFT – QVGA (320x240)Etherneto 10/100 BASE-To HP Auto MDI/MDI-XSD Cardv1, v2c, v3 (pending) GET, SET &TRAPWebpower 5.0; XHTML 1, java script,SSL (Optional)SMTP Client and NTP Client.10000 time stamps of 10 userdefined points156 x 72 x 38mm6,4 x 3 x 1,6”20-75 VDCShutdown: < 18 VDC-40 to +65˚C (-40 to 140˚F)Power Consumption Max 1.5AMax 4.5A (3x LVD max loaded)Contactor OutputsConfigurable InputsSystem Connections• Voltage Sense• Battery Fuse• Load Fuse• Current SenseMax Basic nodesDimensions(WxHxD)3 x LVD control outputs3x NO/NC/Temperature: NTC probe24V, 48V, 60V systemsBattery fuse sense, Open/CloseBattery fuse sense, Open/Close,Pull-Up/Down, Diode Matrix0-20mV and 0-60mV shunt ranges8 units on a single CAN-bus155 x 35 x 80mm6.4 x 1.4 x 3.3”Specifications – I/O Monitor (Type 2)Configurable InputsAlarm OutputsMax I/O MonitornodesPower Consumption Max 3.6WDimensions(WxHxD)6x NO/NC/Analog Voltage[0-75V]6x Relay–Dry/Form C[Max75V/2A/60W]14 units on a single CAN-bus135.1 x 23.5 x 59mm5.3 x 0.9 x 2.3”Specifications are subject to change without notice<strong>242100.50X</strong>.<strong>DS</strong>3– v2Optional Control Devices/CAN nodesPart NumbersPart no. Description242100.300 Battery Monitor242100.301 Load Monitor242100.304 I/O Monitor (Outdoor)242100.306 I/O Monitor Type 3242100.200 Smartnode RS232/485Part no. Description242100.500 <strong>Smartpack2</strong> Master242100.501 <strong>Smartpack2</strong> Basic242100.502 I/O Monitor – Type 2