12.07.2015 Views

Transitional Specification - OEC Business Interiors

Transitional Specification - OEC Business Interiors

Transitional Specification - OEC Business Interiors

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Cable Capacities of Conventional PanelsTest and verify capacitiesfor your individual situation.We recommend thattesting be conducted usingyour specific cableas well as the furniture configurationyou are considering.Cable capacities inthis table are based on nonplenum-ratedcables installedby a cable contractorunder ideal conditions.Figures are approximations.Actual capacities may varyslightly depending on whichmanufacturer produced thecable and the specific fieldconditions.Cat 6 Test Cableså Avaya 1071OD=0.215"∫ Avaya 1081OD=0.250"ç Avaya 2071 PlenumOD=0.195"∂ Avaya 2081 PlenumOD=0.240"´ Belden Media Twist1872AOD=0.365" x 0.165"ƒ Belden Media Twist1874A PlenumOD=0.365" x 0.165"© Berk-TekLan-Mark 1000OD=0.230"˙ Berk-TekLan-Mark 1000PlenumOD=0.225"ˆ CommScopeUltraMediaOD=0.240"∆ General CableCommand LINX 6OD=0.250"˚ Mohawk GigaLANOD=0.240"¬ Nordx 4812LXOD=0.245"µ Nordx 4813XPlenumOD=0.230"Cat 5 Test Cables˜ Berk–Tek24 AWG CMR4-Pair UTP*OD=0.190"..StraightL, T, and XBootå ∫ ç ∂ ´ ƒ © ˙ ˆ ∆ ˚ ¬ µ ˜Cable routing22 22 27 23 25 25 20 20 21 23 20 22 24 28at top of panel 1Cable routing atbase of panel10 8 10 10 12 10 10 10 10 10 8 8 10 16with powerway 2(boot only)Cable routing at baseof panel without32 26 40 36 32 34 28 26 26 32 26 30 32 38power 3Straight through22 L 22 L 27 L 23 L 23 L 22 L 20 L 20 L 19 L 23 L 16 L 20 L 20 L 22 Lcable routing at top22 T 18 T 27 T 23 T 25 T 25 T 20 T 20 T 21 T 23 T 20 T 22 T 24 T 22 Tof panel 1 44 X 35 X 49 X 40 X 37 X 35 X 30 X 30 X 21 X 33 X 31 X 32 X 46 X 22 XCable routing at9 L 8 L 10 L 8 L 10 L 8 L 10 L 8 L 8 L 10 L 8 L 8 L 10 L 10 Lbase of panel with10 T 8 T 10 T 10 T 12 T 10 T 10 T 10 T 10 T 10 T 8 T 8 T 10 T 10 Tpowerway 2 20 X 14 X 20 X 20 X 24 X 20 X 20 X 18 X 20 X 20 X 14 X 16 X 20 X 10 XCable routing at base16 L 13 L 20 L 18 L 16 L 17 L 14 L 13 L 13 L 16 L 13 L 15 L 16 L 25 Lof panel without32 T 26 T 40 T 36 T 32 T 34 T 28 T 26 T 26 T 32 T 26 T 30 T 32 T 25 Tpowerway 3 34 X 23 X 38 X 36 X 16 X 40 X 30 X 28 X 26 X 32 X 24 X 44 X 32 X 25 XChange-of-heightcable routing at top20 15 20 17 20 20 17 16 14 13 18 15 15 24of panel 1Cable-routing10 8 10 10 12 10 10 10 10 10 8 8 10 16in panel boot 2Cable routing in34 28 34 30 32 33 28 30 26 24 29 27 30 50Grumman boot 2.250 <strong>Transitional</strong> <strong>Specification</strong> Guide

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!