Standard FramesStandard frames aredesigned to link horizontallyand stack vertically to createvisual space division andaccommodate electrical andcable routing.Cable carriers organizecables inside frame.Openings in frame allowpass-through cable routing.Frame is structuraland stackable.Slatwall tiles can beadded to accommodatework organizers.End trim is available tofinish the exposed end of arun of frames.Base cover is availableplain or with openings toaccommodate receptacles.You can mix plain and powerbase covers on oppositesides of the same frame.Base cavity can accommodatea powerkit to provideelectrical receptacles in thebase. In addition, if power isnot used at base, the entirebase cavity can be used forcable distribution andvoice/data quick connects.Actual DimensionsDepth (thickness) 3"Width 24", 30", 36", 42", or 48"Height 20.669", 44.685", or 65.354"Stacked height 65.354", 86.024", or 106.693"Door height 86.024". Leveling glide range 2"Leveling glide is adjustedbefore the tile is installed.Range is 2".Top cap finishes the topsurface of frames.Gaskets inside thepanel frame eliminate alllight leaks.Tackable acousticaltiles can be added toprovide a tackable, fabriccoveredsurface.Desk-height cavitycan be added above worksurfaceheight to acceptpowerway and voice/dataquick connects.Pass-through powerkitextends power to powerkit inadjacent frame.Desk-height cavitycover with optionaltray provides openingsfor electrical outlets andvoice/data receptacles.Optional tray below worksurfacecatches cords andcables and aids cable management.Tray can be addedas an option.Non-tackable tiles areavailable with a painted orfabric-covered surface..Product DetailsTiles are available intwelve versions—tackableacoustical, high-performanceacoustical, painted steel, patternedsteel, patterned glass,galvanized steel, fabric-coveredsteel, wood, laminate,markerboard, slatwall, glass,and base fiber-in.Tip: Standard tiles will notwork with enhanced frames.Tip: Enhanced tiles will workon standard frames manufacturedafter June 11, 2001.Top caps are providedwith 45"H and 65"H frames.To stack 20"H frames ontop, the top cap is removedand reinstalled on the topframe. Top caps are availablein metal and wood.Door and frame are availableto provide additionalprivacy for workstations..118 <strong>Transitional</strong> <strong>Specification</strong> Guide

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!