AIR CONDITIONER - Heronhill Air Conditioning Ltd
AIR CONDITIONER - Heronhill Air Conditioning Ltd AIR CONDITIONER - Heronhill Air Conditioning Ltd
FILE NO. SVM-0502011. EXPLODED VIEWS AND PARTS LIST11-1. Indoor Unit (E-Parts Assy)(For Heat pump model)LocationNo.PartNo.Description401 43T60001 Terminal Block, 2P402 43T60002 Terminal Block, 3P403 43T69371 TC Sensor10kΩ 25°C404 43T69005 Sensor, Thermostat 10kΩ 25°C405 43T69079 P.C. Board ASSY,WRS-LED MCC-861LocationNo.PartNo.Description406 43T60077 Fuse, Temperature, 73°C410 43T62003 Cord Clamp411 43T69431 P.C. Board (RAS-10UKHP-ES4)411 43T69432 P.C. Board (RAS-13UKHP-ES4)− 75 −
FILE NO. SVM-0502011. EXPLODED VIEWS AND PARTS LIST11-2. Indoor Unit (E-Parts Assy)(For Cooling model)LocationNo.PartNo.Description402 43T60002 Terminal Block, 3P403 43T69371 TC Sensor10kΩ 25°C404 43T69005 Sensor, Thermostat 10kΩ 25°C405 43T69079 P.C. Board ASSY,WRS-LEDMCC-861Location PartNo. No.Description406 43T60077 Fuse, Temperature, 73°C410 43T62003 Cord Clamp41141143T6936543T69366P.C. Board (RAS-07UKP-ES4)P.C. Board (RAS-10UKP-ES4)411 43T69367 P.C. Board (RAS-13UKP-ES4)412 43T69361 Transformer− 76 −
- Page 25 and 26: 6. CONTROL BLOCK DIAGRAMFILE NO. SV
- Page 27 and 28: 7. OPERATION DESCRIPTIONFILE NO. SV
- Page 29 and 30: 7-2-3. Dry operation([MODE] button
- Page 31 and 32: 7-3. Hi POWER Mode([Hi POWER] butto
- Page 33 and 34: 7-7. Current Limit Control *Heat pu
- Page 35 and 36: 7-8-2. How to cancel auto restart f
- Page 37 and 38: FILE NO. SVM-050207-11. QUIET ModeQ
- Page 39 and 40: DANGER− 38 −FILE NO. SVM-05020
- Page 41 and 42: 8-3. Installation8-3-1. Optional in
- Page 43 and 44: 8-3-3. Installation/Servicing tools
- Page 45 and 46: FILE NO. SVM-050201. Securely fit t
- Page 47 and 48: FILE NO. SVM-050208-4-4. Piping and
- Page 49 and 50: FILE NO. SVM-050208-4-6. Drainage1.
- Page 51 and 52: 8-5-3. EvacuatingAfter the piping h
- Page 53 and 54: FILE NO. SVM-050202. Set the remote
- Page 55 and 56: 9-3. Primary Judgement9-3-1. Role o
- Page 57 and 58: Table 9-4-1FILE NO. SVM-05020Checkc
- Page 59 and 60: FILE NO. SVM-05020Cooling ModelOper
- Page 61 and 62: FILE NO. SVM-05020RAS-13UKP-ES4, RA
- Page 63 and 64: 9-5-5. Only outdoor fan does not op
- Page 65 and 66: FILE NO. SVM-050209-5-7. Only the i
- Page 67 and 68: 9-6. Troubleshooting for Remote Con
- Page 69 and 70: (3) Checking procedureHeat Pump Mod
- Page 71 and 72: Table 9-6-3 Approximate resistance
- Page 73 and 74: FILE NO. SVM-05020No. Part name Pro
- Page 75: FILE NO. SVM-05020No. Part name Pro
- Page 79 and 80: FILE NO. SVM-0502011-4. Outdoor Uni
- Page 81 and 82: 11-6. Outdoor Unit (RAS-13UA-ES4)FI
- Page 83 and 84: FILE NO. SVM-0502011-8. Outdoor Uni
FILE NO. SVM-0502011. EXPLODED VIEWS AND PARTS LIST11-2. Indoor Unit (E-Parts Assy)(For Cooling model)LocationNo.PartNo.Description402 43T60002 Terminal Block, 3P403 43T69371 TC Sensor10kΩ 25°C404 43T69005 Sensor, Thermostat 10kΩ 25°C405 43T69079 P.C. Board ASSY,WRS-LEDMCC-861Location PartNo. No.Description406 43T60077 Fuse, Temperature, 73°C410 43T62003 Cord Clamp41141143T6936543T69366P.C. Board (RAS-07UKP-ES4)P.C. Board (RAS-10UKP-ES4)411 43T69367 P.C. Board (RAS-13UKP-ES4)412 43T69361 Transformer− 76 −