10-2. Outdoor UnitFILE NO. SVM-05020No. Part name Procedures Remarks1 Commonprocedure1) Stop the operation of air-conditioner, anddisconnect the power cord from the ACsupply.2) Remove packed valve cover and Electricparts cover.(3-Screws ∅4 x 10L)3) Remove the cord clamp (2-Screws ∅4 x 16L)and disconnect the connecting cable.4) Remove the upper cabinet (4-Screws ∅4 x 10L)Pulling out upword.5) Remove the front cabinet.(3-Screws ∅4 x 10L)Pull the front right portion toward you, andremove it pulling out upward.Cord clamp2-Screws Ø4 x 16LPacked valve coverElectricparts cover3-Screws Ø4 x10LUppercabinetFrontcabinet− 73 −