FILE NO. SVM-05020RAS-13UKP-ES4, RAS-10UKP-ES4, RAS-07UKP-ES4BlackWhiteGreen / Yellow1 2Indooe Terminal BlockBrownRY01CN31BlueGreen / YellowLNPC Board9-5-3. Outdoor unit does not operateShut off the power supplyfrom AC outlet once and turnit on after 5 seconds.Does the OPERATION lamp blink?NOSee "Power can not be turned on".YESDoes the power turn on by pushingthe [ ] button of the remote control?NOSee "Power can not be turned on".YESIs AC 220-240V supplied betweenterminal block 1 - 2 ?NORelays (RY01) or (IC31 : Cooling only model,Q16 : Heat pump only model)or IC30 is failure.Replace theP.C. board.YESIs cable connection between indoorand outdoor units correct?NOCorrect cabling between indoorand outdoor units.YESCheck items as following procedurein 9-5-4, 9-5-5, 9-5-6– 60−