AIR CONDITIONER - Heronhill Air Conditioning Ltd
AIR CONDITIONER - Heronhill Air Conditioning Ltd AIR CONDITIONER - Heronhill Air Conditioning Ltd
FILE NO. SVM-05020ITEMCapacityMODEL220VRAS-07UKP-ES4RAS-07UA-ES4Cooling240VkW 2.23 2.27PhasePower source V 220 − 2401∅Hz 50Power consumption kW 0.68 0.70Power factor % 98 96Running Indoor A 0.15current Outdoor A 3.00 2.90Starting current A 13Moisture removal lit/h 0.8NoiseRefrigerantRefrigerant controlIndoor (H/M/L) dB 38/32/26Outdoor (220-240V) dB 44 45Name of refrigerantR410ARated amount kg 0.63Capillary tubeGas side size mm ∅9.52Connection typeFlare connectionLiquid side size mm ∅6.35Interconnection Connection typepipeINDOOR UNITMaximum length(One way)Maximum heightdifferenceFlare connectionm10* 1RAS-07UKP-ES4Height mm 275Dimensions Width mm 790Depth mm 208Net weight kg 10Evaporator typeIndoor fan typeFinned tubeCross flow fanHigh fan m 3 /h 570Air volume Medium fan m 3 /h 460Low fan m 3 /h 340Fan motor output W 20Air filterOUTDOOR UNITHoneycomb woven filter with PP frameRAS-07UA-ES4Height mm 530Dimensions Width mm 660Depth mm 240Net weight kg 27Condenser typeOutdoor fan typeFinned tubePropeller fanAirflow volume m 3 /h 1420 1520Fan motor output W 30CompressorSafety deviceLouver typeModelmPA82X1C-4DZDNOutput W 605Fuse, Overload relayAutomatic louverUsable outdoor temperature range °C 15 ~ 435− 5 −
FILE NO. SVM-05020Note : 1• Capacity is based on the following temperature conditions.TemperatureConditionCoolingJIS B8615-1HeatingIndoor unit inlet air temperatureOutdoor unit inlet air temperature(DB) 27°C 20°C(WB) 19°C 15°C(DB) 35°C 7°C(WB) 24°C 6°CNote : 2*1 No need to charge extra refrigerant.− 6 −
- Page 1 and 2: FILE NO. SVM-05020SERVICE MANUALAIR
- Page 3 and 4: 8. INSTALLATION PROCEDURE8-1 Safety
- Page 5: FILE NO. SVM-05020MODEL RAS-10UKHP-
- Page 9 and 10: 2. CONSTRUCTION VIEWSFILE NO. SVM-0
- Page 11 and 12: FILE NO. SVM-050203-2. RAS-10UKHP-E
- Page 13 and 14: 3-4. RAS-10UKP-ES4 / RAS-10UA-ES4FI
- Page 15 and 16: 3. WIRING DIAGRAMFILE NO. SVM-05020
- Page 17 and 18: FILE NO. SVM-050204-3. Outdoor Unit
- Page 19 and 20: FILE NO. SVM-050204-7. Outdoor Unit
- Page 21 and 22: 5-2. RAS-10UKHP-ES4 / RAS-10UAH-ES4
- Page 23 and 24: FILE NO. SVM-050205-4. RAS-10UKP-ES
- Page 25 and 26: 6. CONTROL BLOCK DIAGRAMFILE NO. SV
- Page 27 and 28: 7. OPERATION DESCRIPTIONFILE NO. SV
- Page 29 and 30: 7-2-3. Dry operation([MODE] button
- Page 31 and 32: 7-3. Hi POWER Mode([Hi POWER] butto
- Page 33 and 34: 7-7. Current Limit Control *Heat pu
- Page 35 and 36: 7-8-2. How to cancel auto restart f
- Page 37 and 38: FILE NO. SVM-050207-11. QUIET ModeQ
- Page 39 and 40: DANGER− 38 −FILE NO. SVM-05020
- Page 41 and 42: 8-3. Installation8-3-1. Optional in
- Page 43 and 44: 8-3-3. Installation/Servicing tools
- Page 45 and 46: FILE NO. SVM-050201. Securely fit t
- Page 47 and 48: FILE NO. SVM-050208-4-4. Piping and
- Page 49 and 50: FILE NO. SVM-050208-4-6. Drainage1.
- Page 51 and 52: 8-5-3. EvacuatingAfter the piping h
- Page 53 and 54: FILE NO. SVM-050202. Set the remote
- Page 55 and 56: 9-3. Primary Judgement9-3-1. Role o
FILE NO. SVM-05020ITEMCapacityMODEL220VRAS-07UKP-ES4RAS-07UA-ES4Cooling240VkW 2.23 2.27PhasePower source V 220 − 2401∅Hz 50Power consumption kW 0.68 0.70Power factor % 98 96Running Indoor A 0.15current Outdoor A 3.00 2.90Starting current A 13Moisture removal lit/h 0.8NoiseRefrigerantRefrigerant controlIndoor (H/M/L) dB 38/32/26Outdoor (220-240V) dB 44 45Name of refrigerantR410ARated amount kg 0.63Capillary tubeGas side size mm ∅9.52Connection typeFlare connectionLiquid side size mm ∅6.35Interconnection Connection typepipeINDOOR UNITMaximum length(One way)Maximum heightdifferenceFlare connectionm10* 1RAS-07UKP-ES4Height mm 275Dimensions Width mm 790Depth mm 208Net weight kg 10Evaporator typeIndoor fan typeFinned tubeCross flow fanHigh fan m 3 /h 570<strong>Air</strong> volume Medium fan m 3 /h 460Low fan m 3 /h 340Fan motor output W 20<strong>Air</strong> filterOUTDOOR UNITHoneycomb woven filter with PP frameRAS-07UA-ES4Height mm 530Dimensions Width mm 660Depth mm 240Net weight kg 27Condenser typeOutdoor fan typeFinned tubePropeller fan<strong>Air</strong>flow volume m 3 /h 1420 1520Fan motor output W 30CompressorSafety deviceLouver typeModelmPA82X1C-4DZDNOutput W 605Fuse, Overload relayAutomatic louverUsable outdoor temperature range °C 15 ~ 435− 5 −