12.07.2015 Views

AIR CONDITIONER - Heronhill Air Conditioning Ltd

AIR CONDITIONER - Heronhill Air Conditioning Ltd

AIR CONDITIONER - Heronhill Air Conditioning Ltd

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

FILE NO. SVM-05020Bend the connecting pipe so that it is laid within 43 mmabove the wall surface. If the connecting pipe is laidexceeding 43 mm above the wall surface, the indoorunit may unstably be set on the wall. When bending theconnecting pipe, make sure to use a spring bender soas not to crush the pipe.Bend the connection pipe within a radius of 30 mm.To connect the pipe after installation of the unit (figure)8-4-5. Indoor unit fixing1. Pass the pipe through the hole in the wall, and hookthe indoor unit on the installation plate at the upperhooks.2. Swing the indoor unit to right and left to confirm thatit is firmly hooked up on the installation plate.3. While pressing the indoor unit onto the wall, hook itat the lower part on the installation plate. Pull theindoor unit toward you to confirm that it is firmlyhooked up on the installation plate.270 mm170 mmGas side(To the forefront of flare)Liquid side1Hook here1 Installationplate43 mmOutward form of indoor unitR 30 mm (Use polisin (polyethylene)core or the like for bending pipe.)2HookFig. 8-4-17Press(unhook)80Use the handle of screwdriver, etc.Fig. 8-4-16• For detaching the indoor unit from the installationplate, pull the indoor unit toward you while pushingits bottom up at the specified parts.NOTEIf the pipe is bent incorrectly, the indoor unit mayunstably be set on the wall.After passing the connecting pipe through the pipehole, connect the connecting pipe to the auxiliary pipesand wrap the facing tape around them.PushPushCAUTION• Bind the auxiliary pipes (two) and connectingcable with facing tape tightly. In case of leftwardpiping and rear-leftward piping, bind the auxiliarypipes (two) only with facing tape.Fig. 8-4-18Indoor unitAuxiliary pipesConnecting cableInstallation plate• Carefully arrange pipes so that any pipe does notstick out of the rear plate of the indoor unit.• Carefully connect the auxiliary pipes andconnecting pipes to each other and cut off theinsulating tape wound on the connecting pipe toavoid double-taping at the joint, moreover, sealthe joint with the vinyl tape, etc.• Since dewing results in a machine trouble, makesure to insulate both the connecting pipes. (Usepolyethylene foam as insulating material.)• When bending a pipe, carefully do it, not to crush it.− 47 −

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!