AIR CONDITIONER - Heronhill Air Conditioning Ltd
AIR CONDITIONER - Heronhill Air Conditioning Ltd AIR CONDITIONER - Heronhill Air Conditioning Ltd
FILE NO. SVM-050208-4. Indoor Unit8-4-1. Installation place• A place which provides the spaces around theindoor unit as shown in the above diagram.• A place where there is no obstacle near the air inletand outlet.• A place that allows easy installation of the piping tothe outdoor unit.• A place which allows the front panel to be opened.8-4-2. Cutting a hole and mounting installationplateWhen installing the refrigerant pipes from the rear.CAUTION• Direct sunlight to the indoor unit's wirelessreceiver should be avoided.• The microprocessor in the indoor unit should notbe too close to RF noise sources.(For details, see the owner's manual.)The center of the pipehole is above the arrow.Fig. 8-4-2100 mmPipehole∅65 mm• A place where there are no obstacles such as acurtain that may block the signal from the indoorunit.• Do not install the remote control in a place exposedto direct sunlight or close to a heating source, suchas a stove.• Keep the remote control at least 1 m apart from thenearest TV set or stereo equipment. (This isnecessary to prevent image disturbances or noiseinterference.)• The location of the remote control should bedetermined as shown below.1. After determining the pipe hole position on themounting plate (A), drill the pipe hole (∅65 mm) ata slight downward slant to the outdoor side.NOTE• When drilling a wall that contains a metal lath, wirelath or metal plate, be sure to use a pipe hole brimring sold separately.For installation of the indoor unit, use the paper patternon the back.Indoor unit75°(Side view)7 m(Top view)Indoor unit5 m45°45°5 m* 7 m17085Hook6282.5ReceptionrangeRemotecontrolReceptionrange* : Axial distanceRemote controlPipe holeHookThreadHookPipe hole1InstallationplateFig. 8-4-1Indoor unitWeight7 Mounting screwFig. 8-4-3− 43 −
FILE NO. SVM-050201. Securely fit the installation plate onto the wall byscrewing it in the upper and lower parts to hook upthe indoor unit.2. To mount the installation plate on a concrete wallwith anchor bolts, utilize the anchor bolt holes asillustrated in the above figure.3. Install the installation plate horizontally in the wall.CAUTIONWhen installing the installation plate with amounting screw, do not use the anchor bolt hole.Otherwise the unit may fall down and result inpersonal injury and property damage.Installation plate5 mm dia. holeClip anchor(local parts)CAUTIONFig. 8-4-4AnchorboltProjection15 mm or less7 Mountingscrew∅4 x 25sFailure to firmly install the unit may result inpersonal injury and property damage if the unit falls.8-4-3. Electrical work1. The supply voltage must be the same as the ratedvoltage of the air conditioner.2. Prepare the power source for exclusive use with theair conditioner.CAUTION• This appliance can be connected to the mains ineither of the following two ways.(1) Connection to fixed wiring:A switch or circuit breaker which disconnectsall poles and has a contact separation of atleast 3 mm must be incorporate in the fixedwiring. An approved circuit breaker orswitches must used.(2) Connection with power supply plug:Attach power supply plug with power cordand plug it into wall outlet. An approvedpower supply cord and plug must be used.NOTE• Ensure all wiring is used within its electrical rating.RAS-13UKHP-ES4 RAS-10UKHP-ES4Model RAS-13UKP-ES4 RAS-10UKP-ES4RAS-07UKP-ES4Power sourceMaximumrunning currentPlug socket &fuse rating50 Hz, 220 − 240 V Single phase12A 7.5A16APower cord 1.3 mm 2 or more 1 mm 2 or more• In case of block, brick, concrete or similar typewalls, make 5 mm dia. holes in the wall.• Insert clip anchors for appropriate 7 mountingscrews.NOTE• Secure four corners and lower parts of theinstallation plate with 4 to 6 mounting screws toinstall it.− 44 −
- Page 1 and 2: FILE NO. SVM-05020SERVICE MANUALAIR
- Page 3 and 4: 8. INSTALLATION PROCEDURE8-1 Safety
- Page 5 and 6: FILE NO. SVM-05020MODEL RAS-10UKHP-
- Page 7 and 8: FILE NO. SVM-05020Note : 1• Capac
- Page 9 and 10: 2. CONSTRUCTION VIEWSFILE NO. SVM-0
- Page 11 and 12: FILE NO. SVM-050203-2. RAS-10UKHP-E
- Page 13 and 14: 3-4. RAS-10UKP-ES4 / RAS-10UA-ES4FI
- Page 15 and 16: 3. WIRING DIAGRAMFILE NO. SVM-05020
- Page 17 and 18: FILE NO. SVM-050204-3. Outdoor Unit
- Page 19 and 20: FILE NO. SVM-050204-7. Outdoor Unit
- Page 21 and 22: 5-2. RAS-10UKHP-ES4 / RAS-10UAH-ES4
- Page 23 and 24: FILE NO. SVM-050205-4. RAS-10UKP-ES
- Page 25 and 26: 6. CONTROL BLOCK DIAGRAMFILE NO. SV
- Page 27 and 28: 7. OPERATION DESCRIPTIONFILE NO. SV
- Page 29 and 30: 7-2-3. Dry operation([MODE] button
- Page 31 and 32: 7-3. Hi POWER Mode([Hi POWER] butto
- Page 33 and 34: 7-7. Current Limit Control *Heat pu
- Page 35 and 36: 7-8-2. How to cancel auto restart f
- Page 37 and 38: FILE NO. SVM-050207-11. QUIET ModeQ
- Page 39 and 40: DANGER− 38 −FILE NO. SVM-05020
- Page 41 and 42: 8-3. Installation8-3-1. Optional in
- Page 43: 8-3-3. Installation/Servicing tools
- Page 47 and 48: FILE NO. SVM-050208-4-4. Piping and
- Page 49 and 50: FILE NO. SVM-050208-4-6. Drainage1.
- Page 51 and 52: 8-5-3. EvacuatingAfter the piping h
- Page 53 and 54: FILE NO. SVM-050202. Set the remote
- Page 55 and 56: 9-3. Primary Judgement9-3-1. Role o
- Page 57 and 58: Table 9-4-1FILE NO. SVM-05020Checkc
- Page 59 and 60: FILE NO. SVM-05020Cooling ModelOper
- Page 61 and 62: FILE NO. SVM-05020RAS-13UKP-ES4, RA
- Page 63 and 64: 9-5-5. Only outdoor fan does not op
- Page 65 and 66: FILE NO. SVM-050209-5-7. Only the i
- Page 67 and 68: 9-6. Troubleshooting for Remote Con
- Page 69 and 70: (3) Checking procedureHeat Pump Mod
- Page 71 and 72: Table 9-6-3 Approximate resistance
- Page 73 and 74: FILE NO. SVM-05020No. Part name Pro
- Page 75 and 76: FILE NO. SVM-05020No. Part name Pro
- Page 77 and 78: FILE NO. SVM-0502011. EXPLODED VIEW
- Page 79 and 80: FILE NO. SVM-0502011-4. Outdoor Uni
- Page 81 and 82: 11-6. Outdoor Unit (RAS-13UA-ES4)FI
- Page 83 and 84: FILE NO. SVM-0502011-8. Outdoor Uni
FILE NO. SVM-050201. Securely fit the installation plate onto the wall byscrewing it in the upper and lower parts to hook upthe indoor unit.2. To mount the installation plate on a concrete wallwith anchor bolts, utilize the anchor bolt holes asillustrated in the above figure.3. Install the installation plate horizontally in the wall.CAUTIONWhen installing the installation plate with amounting screw, do not use the anchor bolt hole.Otherwise the unit may fall down and result inpersonal injury and property damage.Installation plate5 mm dia. holeClip anchor(local parts)CAUTIONFig. 8-4-4AnchorboltProjection15 mm or less7 Mountingscrew∅4 x 25sFailure to firmly install the unit may result inpersonal injury and property damage if the unit falls.8-4-3. Electrical work1. The supply voltage must be the same as the ratedvoltage of the air conditioner.2. Prepare the power source for exclusive use with theair conditioner.CAUTION• This appliance can be connected to the mains ineither of the following two ways.(1) Connection to fixed wiring:A switch or circuit breaker which disconnectsall poles and has a contact separation of atleast 3 mm must be incorporate in the fixedwiring. An approved circuit breaker orswitches must used.(2) Connection with power supply plug:Attach power supply plug with power cordand plug it into wall outlet. An approvedpower supply cord and plug must be used.NOTE• Ensure all wiring is used within its electrical rating.RAS-13UKHP-ES4 RAS-10UKHP-ES4Model RAS-13UKP-ES4 RAS-10UKP-ES4RAS-07UKP-ES4Power sourceMaximumrunning currentPlug socket &fuse rating50 Hz, 220 − 240 V Single phase12A 7.5A16APower cord 1.3 mm 2 or more 1 mm 2 or more• In case of block, brick, concrete or similar typewalls, make 5 mm dia. holes in the wall.• Insert clip anchors for appropriate 7 mountingscrews.NOTE• Secure four corners and lower parts of theinstallation plate with 4 to 6 mounting screws toinstall it.− 44 −