5-3. RAS-13UKP-ES4 / RAS-13UA-ES4FILE NO. SVM-05020CoolingIndoor unitHeat exchangerT10.39m(Connecting pipe)∅12.7Cross flow fan0.49m(Connecting pipe)∅6.35O.D.:12.7mmPO.D.:6.35mmPacked valve(∅12.7)Packed valve(∅6.35)CoolingCooling CompressorPA150X2C-4FTAccumulatorCapillary tube∅1.7x600lHeat exchangerRefrigerantCoolingPropeller fanOutdoor unitMark(R410A : 0.95 kg.)means check points of Gas Leak.50HzStandar dpressure P(MPaG)Surface temp. of heatexchang er inter changingpipe T1 (°C)Fan speed(indoor)Note :•Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)Ambient temp.conditions DB/WB(°C)IndoorOutdoorStandard 0.90 9.0 High 27/19 35/24Cooling Overload 1.12 13.0 High 32/23 43/26Low temperature 0.72 2.0 Low 21/15 21/15− 21 −