5-2. RAS-10UKHP-ES4 / RAS-10UAH-ES4FILE NO. SVM-05020CoolingIndoor unitHeat exchangerT10.39m(Connecting pipe)∅9.52HeatingCross flow fan0.49m(Connecting pipe)∅6.35O.D.:9.52mmPO.D.:6.35mmPacked valve(∅9.52)Packed valve(∅6.35)CoolingHeating4-way valveCapillary tube∅1.5x1300lHeating Cooling CompressorPA108X1C-4FZDNAccumulatorCapillary tube∅1.5x1000lHeat exchangerCoolingHeatingPropeller fanOutdoor unitMark(RefrigerantR410A : 0.79 kg.)means check points of Gas Leak.50HzStandar dpressure P(MPaG)Surface temp. of heatexchanger inter changingpipe T1 (°C)Fan speed(indoor)Note :• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)Ambient temp.conditions DB/WB(°C)IndoorOutdoorStandard 2.22 37.0 High 20/15 7/6Heating Overload 3.43 54.0 Low 27/− 24/18Low temperature 2.10 35.0 High 20/− −10/−10Standard 0.95 11.0 High 27/19 35/24Cooling Overload 1.14 15.0 High 32/23 43/26Low temperature 0.85 5.0 Low 21/15 21/15− 20 −