DPF In<strong>com</strong>plete Regeneration MonitorThe DPF In<strong>com</strong>plete Regeneration monitor is used to detect an event where the DPF is not fully regenerated. If aregeneration event is aborted due to duration and the restriction of the DPF is still above a threshold, a fault isindicated. Upon the first occurrence of an in<strong>com</strong>plete regen, the system is put into a “degraded” regen mode.Another regen will be <strong>for</strong>ced in approximately 150 miles unless a normal regen is triggered by the soot load first.Monitor <strong>Summary</strong>:DTCMonitor executionMonitor SequenceSensors OKMonitoring DurationP24A2 – <strong>Diesel</strong> Particulate Filter Regeneration In<strong>com</strong>pleteOnce Per Trip during which an active DPF regeneration occursNoneEGT11, EGT12,EGT13, EGT14, DPFP, INJ20 minutes (maximum)Typical Entry Conditions:Entry condition Minimum MaximumMonitor is activated duringAftertreatment regeneration eventsTypical Malfunction Thresholds:If the restriction is above a threshold, a fault is indicated.FORD MOTOR COMPANY REVISION DATE: FEBRUARY 9, 2012 09.01.00.02-PAGE 60 OF 157