Typical Nominal Voltage Calibration (NVC) Monitor Entry Conditions:Entry condition Minimum MaximumRail pressure 1200 bar 1600 barEngine coolant temperature 70 deg C 100 deg CInjection durationSingle pilot-main injection profile300 usTypical Nominal Voltage Calibration (NVC) Monitor Malfunction Thresholds:If the set point voltage at end of energizing (yellow dot in figure) exceeds the allowable voltage given in the chartbelow <strong>for</strong> the current rail pressure set point or if there exists a persistent deviation between set and measureddischarge time (yellow dot to blue dot in figure) or if there exists a persistent deviation between the set andmeasured voltage at end of energizing (yellow dot in figure)Maximum Allowable Voltage At End of Energizing :Rail pressure (bar) 300 800 1200 2000Maximum allowed voltage (V) 89 91 93 108FORD MOTOR COMPANY REVISION DATE: FEBRUARY 9, 2012 09.01.00.02-PAGE 37 OF 157