OBD Operation Summary for 6.7L Diesel - MotorCraftService.com
OBD Operation Summary for 6.7L Diesel - MotorCraftService.com OBD Operation Summary for 6.7L Diesel - MotorCraftService.com
ECB Valve Actuator Signal Range CheckECB Actuator Open-Load Check Operation:DTCsMonitor executionMonitor SequenceMonitoring DurationP2425 - Exhaust Gas Recirculation Cooling Valve Control CircuitOpen LoadAt Start; when Power-stage is OFF.None2 seconds to register a malfunctionECB Actuator Short-Circuit (P2426/P2427) Check Operation:DTCsMonitor executionMonitor SequenceMonitoring DurationP2426- Exhaust Gas Recirculation Cooling Valve Control Circuit Low,P2427- Exhaust Gas Recirculation Cooling Valve Control Circuit HighContinuous; when power stage ONNone2 seconds to register a malfunction.Urea System Pressure ControlUrea pressure is maintained via:Feedback knowledge of sensed pressure.A set point pressure is determined by engine operating conditions (500 kPa over exhaust backpressure). If apressure increase is desired, the urea pump motor speed is increased by increasing the PWM output. Pressuredecreases are analogous; as the system has a backflow throttle, pressure will decrease to 0 unless the pumpmotor in run continuously.Urea Pump Pressure Control (Normal) Functional Check Operation:DTCsMonitor executionMonitor SequenceSensors/Actuators OKMonitoring DurationP20E8 (Reductant Pressure Too Low)P20E9 (Reductant Pressure Too High)continuousP204C and P204D must complete before setting P20E8 or P20E9Urea pump pressure sensor, Urea pump motor, Urea injector> 60 secFORD MOTOR COMPANY REVISION DATE: FEBRUARY 9, 2012 09.01.00.02-PAGE 116 OF 157
Typical Urea Pump Pressure Control (Normal) Functional Check Entry Conditions:Entry Condition Minimum MaximumReductant system pressurized and ready to injectTypical Urea Pump Pressure Control (Normal) Functional Check Malfunction Thresholds:P20E8: < 350 kPaP20E9: > 700 kPaFORD MOTOR COMPANY REVISION DATE: FEBRUARY 9, 2012 09.01.00.02-PAGE 117 OF 157
- Page 66 and 67: Warm-up profiles with nominal therm
- Page 68 and 69: Primary Coolant Temp Dynamic Monito
- Page 70 and 71: COLD START EMISSION REDUCTION STRAT
- Page 72 and 73: FBC operates in closed-loop control
- Page 74 and 75: Engine SensorsAir Temperature Ratio
- Page 76 and 77: Ambient Air Temperature (AAT) Senso
- Page 78 and 79: Charge Air Cooler Temperature (CACT
- Page 80 and 81: EGR Cooler Downstream Temperature R
- Page 82 and 83: Barometric Pressure and Manifold Ab
- Page 84 and 85: Turbine Upstream Pressure Sensor Pl
- Page 86 and 87: EGR Valve Position SensorAnalog inp
- Page 88 and 89: Engine Coolant & Engine Oil Correla
- Page 90 and 91: Engine Oil Temperature (EOT) Sensor
- Page 92 and 93: Typical Camshaft and Crankshaft Sen
- Page 94 and 95: Typical Fan and Fan Speed Sensor Ch
- Page 96 and 97: MAF Rationality CheckA rationality
- Page 98 and 99: Mass Air Flow Sensor Plausibility C
- Page 100 and 101: Reductant Pressure Sensor Signal Ra
- Page 102 and 103: DEF System Pressure ControlDEF pres
- Page 104 and 105: Reductant Tank Level Sensor Circuit
- Page 106 and 107: Reductant Tank Temperature Circuit
- Page 108 and 109: Exhaust Gas Temperature Sensor Rati
- Page 110 and 111: Exhaust Gas Temperature Rationality
- Page 112 and 113: Diesel Particulate Filter Pressure
- Page 114 and 115: Typical Actuator Jammed Valve Entry
- Page 118 and 119: Reductant Pump MotorThe Reductant P
- Page 120 and 121: Reductant Pump Motor Circuit Checks
- Page 122 and 123: Reductant Dosing Valve Circuit Chec
- Page 124 and 125: Reverting ValveIn order to reverse
- Page 126 and 127: Urea HeatersAqueous urea water solu
- Page 128 and 129: Additional plausibility check for h
- Page 130 and 131: Engine Control Unit (ECU) Monitor O
- Page 132 and 133: Typical Engine Control Unit (ECU) M
- Page 134 and 135: Lack of Communication Codes:CAN Com
- Page 136 and 137: Glow PlugsThe diesel engine uses gl
- Page 138 and 139: Glow Plug Circuit Open Load Check O
- Page 140 and 141: Glow Plug Circuit Resistance Out of
- Page 142 and 143: Miscellaneous ECU Errors:VID Block
- Page 144 and 145: Most vehicle applications no longer
- Page 146 and 147: Transmission Fluid Temperature Sens
- Page 148 and 149: Shift Solenoid Functional Check Ope
- Page 150 and 151: Pressure Control Solenoid Check Ope
- Page 152 and 153: Transmission OutputsShift Solenoids
- Page 154 and 155: On Board Diagnostic ExecutiveThe On
- Page 156 and 157: I/M Readiness CodeThe readiness fun
ECB Valve Actuator Signal Range CheckECB Actuator Open-Load Check <strong>Operation</strong>:DTCsMonitor executionMonitor SequenceMonitoring DurationP2425 - Exhaust Gas Recirculation Cooling Valve Control CircuitOpen LoadAt Start; when Power-stage is OFF.None2 seconds to register a malfunctionECB Actuator Short-Circuit (P2426/P2427) Check <strong>Operation</strong>:DTCsMonitor executionMonitor SequenceMonitoring DurationP2426- Exhaust Gas Recirculation Cooling Valve Control Circuit Low,P2427- Exhaust Gas Recirculation Cooling Valve Control Circuit HighContinuous; when power stage ONNone2 seconds to register a malfunction.Urea System Pressure ControlUrea pressure is maintained via:Feedback knowledge of sensed pressure.A set point pressure is determined by engine operating conditions (500 kPa over exhaust backpressure). If apressure increase is desired, the urea pump motor speed is increased by increasing the PWM output. Pressuredecreases are analogous; as the system has a backflow throttle, pressure will decrease to 0 unless the pumpmotor in run continuously.Urea Pump Pressure Control (Normal) Functional Check <strong>Operation</strong>:DTCsMonitor executionMonitor SequenceSensors/Actuators OKMonitoring DurationP20E8 (Reductant Pressure Too Low)P20E9 (Reductant Pressure Too High)continuousP204C and P204D must <strong>com</strong>plete be<strong>for</strong>e setting P20E8 or P20E9Urea pump pressure sensor, Urea pump motor, Urea injector> 60 secFORD MOTOR COMPANY REVISION DATE: FEBRUARY 9, 2012 09.01.00.02-PAGE 116 OF 157