OBD Operation Summary for 6.7L Diesel - MotorCraftService.com

OBD Operation Summary for 6.7L Diesel - MotorCraftService.com OBD Operation Summary for 6.7L Diesel - MotorCraftService.com

motorcraftservice.com
from motorcraftservice.com More from this publisher
12.07.2015 Views

ECB Valve Actuator Signal Range CheckECB Actuator Open-Load Check Operation:DTCsMonitor executionMonitor SequenceMonitoring DurationP2425 - Exhaust Gas Recirculation Cooling Valve Control CircuitOpen LoadAt Start; when Power-stage is OFF.None2 seconds to register a malfunctionECB Actuator Short-Circuit (P2426/P2427) Check Operation:DTCsMonitor executionMonitor SequenceMonitoring DurationP2426- Exhaust Gas Recirculation Cooling Valve Control Circuit Low,P2427- Exhaust Gas Recirculation Cooling Valve Control Circuit HighContinuous; when power stage ONNone2 seconds to register a malfunction.Urea System Pressure ControlUrea pressure is maintained via:Feedback knowledge of sensed pressure.A set point pressure is determined by engine operating conditions (500 kPa over exhaust backpressure). If apressure increase is desired, the urea pump motor speed is increased by increasing the PWM output. Pressuredecreases are analogous; as the system has a backflow throttle, pressure will decrease to 0 unless the pumpmotor in run continuously.Urea Pump Pressure Control (Normal) Functional Check Operation:DTCsMonitor executionMonitor SequenceSensors/Actuators OKMonitoring DurationP20E8 (Reductant Pressure Too Low)P20E9 (Reductant Pressure Too High)continuousP204C and P204D must complete before setting P20E8 or P20E9Urea pump pressure sensor, Urea pump motor, Urea injector> 60 secFORD MOTOR COMPANY REVISION DATE: FEBRUARY 9, 2012 09.01.00.02-PAGE 116 OF 157

Typical Urea Pump Pressure Control (Normal) Functional Check Entry Conditions:Entry Condition Minimum MaximumReductant system pressurized and ready to injectTypical Urea Pump Pressure Control (Normal) Functional Check Malfunction Thresholds:P20E8: < 350 kPaP20E9: > 700 kPaFORD MOTOR COMPANY REVISION DATE: FEBRUARY 9, 2012 09.01.00.02-PAGE 117 OF 157

ECB Valve Actuator Signal Range CheckECB Actuator Open-Load Check <strong>Operation</strong>:DTCsMonitor executionMonitor SequenceMonitoring DurationP2425 - Exhaust Gas Recirculation Cooling Valve Control CircuitOpen LoadAt Start; when Power-stage is OFF.None2 seconds to register a malfunctionECB Actuator Short-Circuit (P2426/P2427) Check <strong>Operation</strong>:DTCsMonitor executionMonitor SequenceMonitoring DurationP2426- Exhaust Gas Recirculation Cooling Valve Control Circuit Low,P2427- Exhaust Gas Recirculation Cooling Valve Control Circuit HighContinuous; when power stage ONNone2 seconds to register a malfunction.Urea System Pressure ControlUrea pressure is maintained via:Feedback knowledge of sensed pressure.A set point pressure is determined by engine operating conditions (500 kPa over exhaust backpressure). If apressure increase is desired, the urea pump motor speed is increased by increasing the PWM output. Pressuredecreases are analogous; as the system has a backflow throttle, pressure will decrease to 0 unless the pumpmotor in run continuously.Urea Pump Pressure Control (Normal) Functional Check <strong>Operation</strong>:DTCsMonitor executionMonitor SequenceSensors/Actuators OKMonitoring DurationP20E8 (Reductant Pressure Too Low)P20E9 (Reductant Pressure Too High)continuousP204C and P204D must <strong>com</strong>plete be<strong>for</strong>e setting P20E8 or P20E9Urea pump pressure sensor, Urea pump motor, Urea injector> 60 secFORD MOTOR COMPANY REVISION DATE: FEBRUARY 9, 2012 09.01.00.02-PAGE 116 OF 157

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!