12.07.2015 Views

Untitled - BIBUS SK, sro

Untitled - BIBUS SK, sro

Untitled - BIBUS SK, sro

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

PVA PIAB Vacuum AcademyPIAB’S KNOW-HOW FOR COMPETITIVE ADVANTAGESReliable and efficient production is an extremely valuable asset for a company. Handling failures, rejection ofproducts, re-settings and breakdowns cause production losses and costs that can never be regained.We at PIAB work with vacuum technology, but our objective is to improve our customers’ profitability byincreasing their production capacity. This makes us a superior supplier. Where other firms talk about airflows,valves and filtration, we focus on matters related to set-up times, cycle times, speed, flexibility, product rejectionand maintenance.Would you like to learn how to think along these lines? Here you will find a few examples of fields of knowledgewhere you can take advantage of the fact that we have gathered our competence and experience in completeeducational training programmes. Don’t hesitate to ask us about tailor-made training programmes. We do haveextensive knowledge that we would like to share with you.Welcome to the PIAB Vacuum Academy!PVACOURSES OFFERED..................................................................................4VACUUM THEORY..................................................................................5EXPRESSIONS AND UNITS..................................................................................6VACUUM PUMPS..................................................................................8VACUUM SYSTEMS................................................................................11SAFETY................................................................................13SUCTION CUPS................................................................................14TABLES................................................................................15The PIAB Vacuum Academy trainsyour company’s co-workers to makesounder pre-purchasing decisions,find new fields of application,develop production processes andmake your business more profitable.Training courses are held whereverPIAB is represented. Moreover, theycan be held on your companypremises and adapted to meetspecial needs whenever you desire.Specifications subject to change without notice. 3


PVA PIAB VACUUM ACADEMYCOURSES OFFERED1. BASIC VACUUM TECHNOLOGYTraining phases: Introduction to vacuumtechnology The role played by vacuum technology in pursuitof improved productivity and profitability Minimizing cycle times Integration of vacuum Various types of vacuum systems Dimensioning vacuum systems Control systems Optimal use of energy4. VACUUM TECHNOLOGY IN THE AUTOMOTIVEINDUSTRYTraining phases: The role played by vacuum technology in pursuitof improved productivity and profitability Design and function of vacuum systems forhandling metal sheets, glass and plastic parts Evaluation of technicalsolutions2. OPTIMIZING A VACUUM SYSTEM AND ITSPARAMETERSTraining phases: Introduction to “OVM” Vacuum pump and vacuum system parameters Interactive aids for calculating flows, responsetimes, pressure drops, etc. Interactive aids for calculating productivity andcost chganges, energy costs, etc. “Integration Into Your Own Product” Laboratory work and tests “Workshops” Application examples5. VACUUM TECHNOLOGY IN THE GRAPHICINDUSTRYTraining phases: The role played by vacuum technology inachieving improved productivity Examples of applications and functions that canbe developed and improved by using vacuumtechnology Evaluation of technical solutions3. VACUUM TECHNOLOGY IN THE PACKAGINGINDUSTRYTraining phases: The role played by vacuum technology in pursuitof improved productivity and profitability Packaging applications using vacuum technology Integration of vacuum Optimal use of energy Evaluation oftechnical solutions6. VACUUM TECHNOLOGY IN THE POWDER ANDBULK INDUSTRYTraining phases: Basic knowledge of vacuum conveying of powderand bulk Design and function of a bulk handling systemusing vacuum technology Integration of vacuum Optimal use of energy Evaluation of technicalsolutions4 Specifications subject to change without notice.


PVA PIAB VACUUM ACADEMYVACUUM THEORYWHAT IS VACUUM?When using the terms ”vacuum”, ”negativepressure”, ”suction”, etc., we mean a pressure thatis lower than the atmospheric pressure, which is thepressure of the weight of the air above us. At sealevel it usually is 1,013 mbar = 101.3 kPa. 1 Paequals 1 N/m 2 , which means that a column of airwith a cross-sectional area of 1 m 2 presses on thesurface of the earth with a force of around100,000 N. By reducing the pressure in a closedspace the atmospheric pressure becomes apotential energy source.PVAA vacuum cleaner does not suck. Air and dust arepressed into the vacuum cleaner by the surroundinghigher atmospheric pressure.1. Atmospheric pressure = 0 at an altitude of1,000 km2. 1 bar (101.3 kPa) at sea levelA suction cup adheres to a surface by the surroundinghigher pressure.ALTITUDE ABOVE SEA LEVELAs the atmospheric pressure is the working force,the force will consequently change with theatmospheric pressure. This means that the presentbarometric pressure and the altitude above sea levelmust be taken into consideration. Up to 2,000 m,the pressure is reduced by around 1% per 100 m. Anapplication which is dimensioned to hold 100 kg atsea level, can manage only 89 kg at an altitude of1,000 m.The chapter “Tables” shows the effect of theatmospheric pressure on the vacuum level.At the summit of Mount Everest (8,848 m) the atmosphericpressure is approximately 330 mbar (33 kPa).A DEFINITION OF VACUUM IS:”A room without matter”. In everyday language; ”Air-free or almost air-free space”.Source: Nationalencyklopedin, Bra Böcker, Höganäs, Sweden.Specifications subject to change without notice. 5


PVA PIAB VACUUM ACADEMYEXPRESSIONS AND UNITSIn everyday speech there are many different expressions and units for pressure below the atmospheric pressure.It is therefore important to relate to the same vocabulary in discussions. The adjoining table shows some commonexpressions and units used in connection with vacuum. For conversion tables between the different units, seetables No. 1, 2 and 3.ExpressionsUnitsUnder pressure -kPa barAbsolute pressure inHg mm H 2O% vacuum (% of vacuum) mmHg torrNegative pressure hPa mbarDIFFERENT TERMS FOR PRESSURE IN RELATION TO "ABSOLUTE VACUUM"Physically there is only one kind of ”pressure” andthat is the one that starts from ”0” or absolutevacuum. Everything above ”0” is pressure andcorrectly named absolute pressure. Normalatmospheric pressure (101.3 kPa) is used as areference, which is why the term “positive pressure”or “negative pressure” is used. Earlier the term “%vacuum” was used, where 0% was atmosphericpressure and 100% absolute vacuum.Consequently, in industry, -kPa is the unit used mostoften since it nearly corresponds to “% vacuum”. Inthe chemical branch of industry, and in deepvacuum, mbar is generally used. Thus, it is veryimportant to be clear about which unit and referencepoint are used. In this catalogue, -kPa is generallyused (as in industry), and for laboratory pumps,mbar absolute is specifically used.This diagram shows the relation between absolute,negative and positive pressures. It also illustrates theproblem that may occur if the pressure is not clearlyspecified. 30 kPa can ”carelessly spoken” imply threedifferent values.APPLIED VACUUM CAN NORMALLY BE DEVIDED INTO THREE MAIN CATEGORIESBlowers or low vacuum 0–20 -kPa For ventilation, cooling, vacuum cleaning, ...Industrial vacuum 20–99 -kPa For picking, holding, automation, ...Process vacuum 99 -kPa – Deep vacuum for laboratories, manufacturing of microchips, plating, ...6 Specifications subject to change without notice.


PVA PIAB VACUUM ACADEMYENERGY NEEDS FOR DIFFERENT VACUUM LEVELSThe energy required to create vacuum increasesasymptotically towards infinity with increasedvacuum. To obtain optimum energy exchange it isvery important to choose the least possible vacuum.To illustrate the energy needs, a cylinder with apiston (piston pump) is suitable.According to Boyle’s Law the pressure (p) in a gas isinversely proportional to its volume (V) at constanttemperature:P. x V. = P 1x V 1This means that increased volume gives a lowerpressure.By pulling the piston slowly, the distance extendedwill show the increased energy needs. Thetemperature is not constant in practice. However, atslow operation the temperature effect is negligible.PVAENERGY REQUIREMENT AT INCRAESED VACUUMThe diagram illustrates the energy requirement atincreased vacuum. As can be seen, the energyrequirement increases drastically above 90 -kPa,which is why a vacuum level below this is alwaysadvisable.a) Pressure below atmospheric -kPa,b) Energy factorSpecifications subject to change without notice. 7


PVA PIAB VACUUM ACADEMYVACUUM PUMPSMECHANICAL PUMPSThe main principle for all mechanical pumps is thatthey convey, in one way or another, a certain volumeof air from the suction side (the vacuum side) to theexhaust side. In that way they create a vacuum.Mechanical pumps usually have an electric motor aspower source, but it can also be an internalcombustion engine, a hydraulic or a compressed airdrivenpump.FansVacuum pump Advantages DisadvantagesCentrifugal blower Few moving partsLarge suction volumesStrongLow maximum vacuumSlow start-up and long stop timeHigh noise levelRegenerative blowerFew moving partsLarge suction volumesLow energy consumptionLow maximum vacuumSlow start-up and long stop timeHigh noise levelDisplacement pumpsVacuum pump Advantages DisadvantagesPiston pump Relatively low price High heat emissionLow maximum vacuumMembrane pumpFew moving partsCompactLow priceSmall suction volumesVane pumpHigh vacuum and flowRelatively low noise levelSensitive to contaminationRelatively high priceHigh service requirementsHigh heat emissionRoots pumpHigh flowLow service requirementsHigh priceHigh heat emissionHigh noise level8 Specifications subject to change without notice.


PVA PIAB VACUUM ACADEMYCOMPRESSED AIR-DIVEN EJECTOR PUMPSAll ejector pumps are driven with pressurised gas,usually compressed air. The compressed air flowsinto the ejector pump, where it expands in one ormore ejector nozzles. When expanding, the storedenergy (pressure and heat) is converted into motiveenergy. The speed of the compressed air jetincreases rapidly, while the pressure and thetemperature go down, attracting more air andthereby creating a vacuum on the suction side.Some ejector pumps may also be used to blow air.Compressed air-driven ejector pumpsVacuum pump Advantages DisadvantagesSingle-stage ejector Low priceNo heat emissionCompactHigh noise levelGives either high flow or highvacuumPoor efficiencyPVAMulti-stage ejectorHigh efficiencyLow energy consumptionHigh reliabilityLow noise levelNo heat emissionCOAX® technologyHigh efficiencyLow energy consumptionHigh reliabilityLow noise levelNo heat emissionOperates even at low feedpressureIntegrated featuresModularly builtEasy to supplement andupgrade later onEasy to cleanSpecifications subject to change without notice. 9


PVA PIAB VACUUM ACADEMYVACUUM FLOWSIn order to obtain a pressure that is lower thanatmospheric pressure in a container, some of the airmass must be removed by the aid of a vacuumpump. Half of the air mass must be removed toobtain a vacuum level of 50 -kPa. The air sucked intothe pump per unit of time is called the vacuum flowand is a measure of how quickly the pump isworking. Many manufacturers of vacuum pumps, forexample, cylinder pumps, state displacement flowinstead of flow in normal litres. Displacement flow =Cylinder volume per number of revolutions. Thisvalue is constant and can incorrectly influence theobserver to believe that the vacuum flow is constantduring the entire emptying process; it is given in l/s(litre per second). The air becomes thinner andthinner for every stroke of the cylinder until the pumpreaches the maximum vacuum level when thevacuum flow = 0. Displacement flow is often calledvolume flow.The air mass sucked out is given as Nl/s (normallitre/second), and refers to the air flow pumped outto the atmosphere. Here, consideration is taken forthe air becoming thinner and thinner as it is beingpumped out. The air mass sucked out is also calledgas flow.TABLE OF CONVERSION UNITS FOR SOME WAYS OF STATING VACUUM FLOWUnitsVacuum level -kPa0 10 20 30 40 50 60 70 80 90Vacuum flow l/s 10 10 10 10 10 10 10 10 10 10m 3 /h 36 36 36 36 36 36 36 36 36 36Free air Nl/s 10 9 8 7 6 5 4 3 2 1Nm 3 /h 36 32.4 28.8 25.2 21.6 18 14.4 10.8 7.2 3.610 Specifications subject to change without notice.


PVA PIAB VACUUM ACADEMYVACUUM SYSTEMSWhen making a vacuum system/lifting device there are several different methods to increase safety andreliability. To give efficient operation and good economy it is important that the designed system is made for aspecific application. In addition to the choice of suction cups with attachments, the type and size of vacuumpumps, accessories, safety level and type of system must also be decided upon.SEALED SYSTEMSFor sealed systems the capacity of the pump isdetermined by how fast the system can beevacuated to a certain vacuum level. This capacity iscalled the evacuation time of the pump and isnormally specified in s/l. This value is multiplied bythe volume of the system in order to obtain theevacuation time to the desired vacuum level.PVANON-SEALED SYSTEMSWith non-sealed systems (lifting of porous materials)the case is different. To maintain the desiredvacuum level the pump must have the capacity topump away the air leaking in. Leakage can be due to,for example, porous material or that one is forced tolift over holes. By establishing the leaking flow, it ispossible, by reading the pump data, to find the rightpump for the application in question.If the leakage occurs via a known aperture, the flowcan be established according to the adjoiningdiagram. The diagram gives values for leakage flowwhen the leakage area is known. The leakage flow isvalid when there is an opening of 1 mm 2 (normalatmospheric pressure at sea level). To obtain thetotal flow, the value is multiplied by the total leakagearea. See also table No. 7 in the “Tables” chapter.When the leakage occurs through a porous materialor in an unknown way, the flow can be establishedby a test with a vacuum pump. The pump isconnected to the system and the obtained vacuumlevel is read. (It should be at least 20 -kPa.) The flowthat is pumped away at this vacuum level can beseen on the page of the particular pump. This flowroughly corresponds to the leaking flow.At 47 -kPa the air reaches sonic velocity, and consequentlythe flow is constant.ENERGY-SAVING SYSTEMSElectrically driven, mechanical vacuum pumpsnormally work during the whole operating cycle andthe vacuum requirements are controlled by a valveon the vacuum side. In systems with compressed airdrivenvacuum pumps it is often possible to save alot of energy. As these pumps have a faster reactiontime (fast start-up and stop time) the pump can beshut off when the vacuum is no longer needed. Theprinciples of a simple energy-saving system areshown to the right. Many pumps can be deliveredwith an energy-saving system as standard.A = Vacuum pump with non-return valve.B = Vacuum control unit.C = Feed valve for compressed air.D = Release valve.Specifications subject to change without notice. 11


PVA PIAB VACUUM ACADEMYWHY A DECENTRALIZED VACUUM SYSTEM?The impact of losses in a centralized vacuum systemdue to tubing, bends, fittings, valves, filters, etc., issubstantial and has to be compensated byincreasing the size of the vacuum pump. Adecentralized system with the vacuum pump/cartridge placed right at the suction cup eliminatesthe risk for losses in the vacuum piping and theneed for expensive oversized components.Furthermore, the response time will be reducedsubstantially without unnecessary volume to beevacuated, and each cup is independent. A pressureloss in one cup will not affect the others.1. Centralized system. a) Compressed air, b) Vacuum,c) Vacuum filter2. Traditional decentralized system.3. The ultimate decentralized system.12 Specifications subject to change without notice.


PVA PIAB VACUUM ACADEMYSAFETYSpecial safety requirements govern manual vacuum lifting devices (SS 765 5801 in Sweden). When designingthese devices, allow for at least a double safety margin on the lifting force at the designated vacuum level. Therelease is blocked during lifts so that the load is not released by mistake. Further safety is achieved by usingsound or light signals that give a warning if the vacuum level falls below a certain set value.VACUUM TANKAs a protection against loss of vacuum, for example,if a compressed air hose would break, a non-returnvalve is normally fitted near the pump. A vacuumtank between the vacuum pump and the suction cupgives an extra safety margin if an unexpectedleakage or loss of vacuum should occur.PVADUAL CIRCUIT SYSTEMLifting devices with several suction cups are oftenbuilt as two independent vacuum systems withseparate vacuum pumps, each of them capable ofholding the load with sufficient safety factor.CONCLUSIONDeep vacuum requires a lot of energy. Furthermore, preferably the vacuum pump should be located as close aspossible to the suction point in order to minimize the volume that needs to be evacuated. A vacuum tank shouldbe used in applications when a ”rapid”, high-flow vacuum is needed.Specifications subject to change without notice. 13


PVA PIAB VACUUM ACADEMYSUCTION CUPSHOW DOES A SUCTION CUP WORK?A suction cup adheres to a surface as thesurrounding pressure (atmospheric pressure) ishigher than the pressure between the suction cupand the surface. To create the low pressure in thesuction cup it is connected to a vacuum pump. Thelower the pressure (higher vacuum), the greater theforce on the suction cup.ADVANTAGES AND LIMITATIONS OF THE SUCTION CUPMaterial handling with suction cups is a simple,inexpensive and reliable technique. It is therefore asolution worth considering before going over to morecomplicated methods. Suction cups can lift, moveand hold objects that weigh just a few grams up toseveral hundred kilogramsAdvantagesEasy installationLow service requirementsLow priceDoes not damage the materialhandledQuick attachment anddetachmentLimitationsLimited force (atmosphericpressure)Positioning accuracySIZING SUCTION CUPSSuction cups have quite different capacitiesdepending on the design. Please see the values inthe tables.ENERGY REQUIREMENTS AT DIFFERENT VACUUM LEVELSA deep vacuum means that the suction cup has towork harder and thus wears out quicker; also theenergy requirements increase at higher vacuumlevels. If the vacuum level increases from 60 to 90-kPa, the lifting force increases by 1.5 times but withten times the energy requirement. It is better tomaintain a lower vacuum level and instead increasethe suction cup area. In many applications, a goodtarget for the vacuum level could be 60 -kPa; at thislevel you get a high lifting force with relatively lowenergy requirements.CONSIDER THE HEIGHT ABOVE SEA LEVELAtmospheric pressure decreases with increasedheight. This means that the available forcedecreases at the same rate. An application designedfor lifting 100 kg at sea level, can only manage tohold 89 kg at 1,000 metres. A vacuum gauge isnormally calibrated with atmospheric pressure as areference. This means that the gauge showsavailable vacuum levels at different heights.LIFTING FORCE IN DIFFERENT DIRECTIONSA suction cup can be used irrespective of whetherthe force is perpendicular or parallel to the surface.If the force is parallel, it is transferred throughfriction between the suction cup and the surface. Asuction cup with cleats is most suitable in this casebecause it is rigid and provides high friction.14 Specifications subject to change without notice.


PVA PIAB VACUUM ACADEMYTABLESIn everyday speech, many different expressions and units are used for both pressure and flow. It is important toagree on what is meant by them.PRESSUREP=F/A (Force/Area).SI unit (Système International d’Unités): Pascal (Pa). 1 Pa = 1 N/m 2 .Common multiple units: MPa and kPa.PVAPa (N/m 2 ) bar kp/cm 2 torr psi (lbf/in 2 )1 0.00001 10.1972x10 -6 7.50062x10 -3 0.145038x10 -3100 000 1 1.01972 750.062 14.503898 066.5 0.980665 1 735.559 14.2233133.322 1.33322x10 -3 1.35951x10 -3 1 19.3368x10 -36 894.76 68.9476x10 -3 0.145038x10 -3 51.7149 1Table No. 11 torr = 1 mm HG à 0°C,1 mm column of water = 9.81 PaPRESSURE ABOVE ATMOSPHERICTable No. 2kPa bar psi kp/cm 21,013 10.13 146.9 10.31,000 10 145 10.2900 9 130.5 9.2800 8 116 8.2700 7 101.5 7.1600 6 87 6.1500 5 72.5 5.1400 4 58 4.1300 3 §43.5 3.1200 2 29 2100 1 14.5 10 0 0 0PRESSURE BELOW ATMOSPHERICkPa mbar torr -kpa -mmHg -inHg % vacuumSea level 101.3 1,013 760 0 0 0 090 900 675 10 75 3 1080 800 600 20 150 6 2070 700 525 30 225 9 3060 600 450 40 300 12 4050 500 375 50 375 15 5040 400 300 60 450 18 7030 300 225 70 525 21 7020 200 150 80 600 24 8010 100 75 90 675 27 90Absolute vacuum 0 0 0 101.3 760 30 100Table No. 3Specifications subject to change without notice. 15


PVA PIAB VACUUM ACADEMYCHANGE IN ATMOSPHERIC PRESSURE IN RELATION TO ALTITUDE (HEIGHT ABOVE SEA LEVEL)A vacuum gauge is normally calibrated with normalatmospheric pressure at sea level as a reference,1013.25 mbar, and is influenced by the surroundingatmospheric pressure in accordance with the tablebelow.The vacuum gauge shows the differential pressurebetween atmospheric pressure and absolutepressure. This means that the gauge shows whatvacuum level is available at different heights.ATMOSPHERIC PRESSUREBarometric pressureThe reading on the vacuum gauge at 1,013.25 mbarmmHg mbar Equivalent m above sea level 60 -kPa 75 -kPa 85 -kPa 90 -kPa 99 -kPa593 790.6 2,000 37.7 52.7 62.7 67.7 76.7671 894.6 1,000 48.1 63.1 73.1 78.1 87.1690 919.9 778 50.7 65.7 75.7 80.7 89.7700 933.3 655 52.0 67.0 77.0 82.0 91.0710 946.6 545 53.3 68.3 78.3 83.3 92.3720 959.9 467 54.7 69.7 79.7 84.7 93.7730 973.3 275 56.0 71.0 81.0 86.0 95.0740 986.6 200 57.3 72.3 82.3 87.3 96.3750 999.9 111 58.7 73.7 83.7 88.7 97.7760 1,013.25 0 60.0 75.0 85.0 90.0 99.0Table No. 4*) at normal barometric pressure.FLOWSFlows, volume per unit of time. Quantity designations: Q, q, = V/t (volume/time).SI Unit: cubic metres per second (m 3 /s).Common multiple units: l/min, l/s, m 3 /h.m 3 /s m 3 /h l/min l/s ft 3 /min (cfm) *1 3,600 60,000 1,000 2,118.90.28x10 -3 1 16.6667 0.2778 0.588516.67x10 -6 0.06 1 0.0167 0.0351x10 -3 3.6 60 1 2.11890.472x10 -3 1.6992 28.32 0.4720 1Table No. 5*) 1 ft » 0.305 m16 Specifications subject to change without notice.


PVA PIAB VACUUM ACADEMYFLOWS, IMPORTANT VALUESl/s m 3 /min m 3 /h cfm1 0.06 3.60 2.122 0.12 7.20 4.243 0.18 10.80 6.364 0.24 14.40 8.475 0.30 18.00 10.596 0.36 21.60 12.717 0.42 25.20 14.838 0.48 28.80 16.959 0.54 32.40 19.0710 0.60 36.00 21.1911 0.66 39.60 23.3012 0.72 43.20 25.4213 0.78 46.80 27.5414 0.84 50.40 29.6615 0.90 54.00 31.7816 0.96 57.60 33.9017 1.02 61.20 36.0218 1.08 64.80 38.1319 1.14 68.40 40.2520 1.20 72.00 42.3725 1.50 90.00 52.9730 1.80 108.00 63.5635 2.10 126.00 74.1540 2.40 144.00 84.7445 2.70 162.00 95.3450 3.00 180.00 105.93Table No. 6PVALEAKAGE FLOWSThe table below shows the leakage flow at different levels and through an opening of 1 mm 2 .Vacuum level -kPa Leakage flow l/s and mm 210 0.1120 0.1730 0.1840 0.2 *)Table No. 7*) From about 47 to 100 -kPa the flow is constant.PRESSURE DROP IN COMPRESSED AIR HOSESWhen installing compressed air hoses it is importantthat the dimension (diameter) and length do not leadto excessive pressure drops. PIAB vacuum pumpsare supplied with recommended hose dimensionsthat will not cause excessive pressure drops atlengths below 2 m.In cases when the pressure drop has to becalculated, the formula below can be used.Δ P = Pressure drop in kPaqv = Flow in m 3 /sd = Inner diameter in mmL = Length of compressed air hoses in mP1 = The absolute starting pressure in kPaSpecifications subject to change without notice. 17


Vacuum pumpsFor many years, PIAB has been developing a range of vacuum components that cover the widely varying needsof the market. Because we constantly strive to improve our products and adapt them to market needs byincorporating the latest technology, our customers can rely on PIAB to provide the best possible solution.Regardless of whether an application is in the packaging, foodstuff, pharmaceutical, automotive, plastic,electronic, chemical or some other industry, the best way to solve a vacuum-related problem is to use PIABcomponents.Vacuum pumpsFUNCTIONAL DESCRIPTIONS................................................................................20SELECTION GUIDE................................................................................22MODELS................................................................................28VACUUM PUMPSVacuum pumps P2010 .............................................30Vacuum pumps P3010 ..............................................38Vacuum pumps P3010 AVM ...................................58Vacuum pumps PMAT COAX® ....................................62Vacuum pumps P6010 ..............................................64Vacuum pumps MINI .................................................86Vacuum pumps CLASSIC .........................................110Vacuum pumps CLASSIC MP....................................126Vacuum pumps MAXI...............................................146Mounting brackets CLASSIC and CLASSIC MP ...........157Specifications subject to change without notice. 19


VACUUM PUMPSFUNCTIONAL DESCRIPTIONSMULTI-STAGE EJECTORPIAB vacuum pumps are of the multi-stage ejectortype – a technology patented by PIAB in 1973.These vacuum pumps were developed to provideextra vacuum flow in combination with deepmaximum vacuum levels while keeping energyconsumption at a minimum.PIAB pumps have no moving parts that vibrate orwear out – important features that contribute heavilyto outstanding operational reliability and a pleasant,noise-free working environment.PRINCIPLE OF PIAB VACUUM PUMPSPIAB vacuum pumps are compressed air-drivenvacuum pumps. The unique construction makesmaximum use of the compressed air and thereforeconsumes less energy. Large vacuum flows and highlevels of vacuum are characteristic of PIAB’s vacuumpumps.When compressed air (1) passes through thenozzles (2), air is pulled through with the stream ofcompressed air. “Suction” is thus created at theopening of each stage (3), resulting in low pressure,vacuum (4).ADVANTAGES OF PIAB VACUUM PUMPS Reliability Low energy consumption Fast response High efficiency Require a minimum of service Small size and low weight Easy to install Low noise level No heat emission No vibrations5-YEAR WARRANTY20 Specifications subject to change without notice.


VACUUM PUMPSCOAX® TECHNOLOGYPIAB’s latest patented technology is an offshoot ofthe multi-stage ejector principle.COAX® ensures excellent performance at both lowand high feed pressures – ideal for situations wherecompressed air lines deliver air at low or fluctuatingpressures.Pumps based on the COAX® technology can operatewithin the range of 0.17 to 0.60 MPa.PRINCIPLE OF THE COAX® TECHNOLOGYP3010 is based on this new technology, derivedfrom the multi-stage ejector principle. Note that botha filter and check valves are integrated into theejector section.When compressed air (1) passes through thenozzles (2), air is pulled through with the stream ofcompressed air. “Suction” is thus created at theopening of each stage (3).123Vacuum pumpsADVANTAGES OF PIAB VACUUM PUMPS BASED ON COAX® TECHNOLOGY Outstanding performance even at low or fluctuatingfeed pressures Integrated features Flexible, module-based design Easy to supplement and upgrade Easy to clean Highly efficient Low energy consumption Short starting and stopping times High operational reliability Minimal maintenance Compact Simple to install Low noise level Generate no heat No vibrationsSpecifications subject to change without notice. 21


VACUUM PUMPSSELECTION GUIDEWHICH PUMP SHOULD I SELECT?PIAB vacuum pumps are divided into five series having different characteristics: Pi, L, M, X and H. When youknow what these letters mean and the applications for which they were developed, it will be easier to select theright pump.BiThe Bi Cartridge has been developed to operate at arelatively high vacuum level at very low feed pressure(0.18 MPa). The Bi Cartridge is recommended whenyou want to ensure high safety of operation in pickand-placeapplications, for example, in the electronicindustry, where many vacuum units are distributedand where there is a risk of pressure drops. The BiCartridge can handle vacuum levels down to -83 kPa.P2010 BiRecommended operating rangeMaximum vacuum levelFeed pressure0–80 -kPa83 -kPa0.11–0.22 MPaPiPi cartridges have been developed to achieve a highvacuum level at low feed pressures. They are idealwhen pressures in compressed air lines fluctuate. Picartridges are recommended in situations such ashandling sheet metal or glass or other non-porousproducts, where you need good vacuum flow and ahigh-level vacuum. Pi can deliver high vacuum levelsdown to 90 -kPa.P3010 PiRecommended operating rangeMaximum vacuum levelFeed pressureP6010 PiRecommended operating rangeMaximum vacuum levelFeed pressure0–85 -kPa90 -kPa0.17–0.6 MPa0–85 -kPa90 -kPa0.17–0.4 MPaSiSi cartridges are designed to provide extra vacuumflow. They are highly recommended for handlingporous materials such as corrugated board and forhigh-volume evacuation in, for example, a fastcyclingsystem where it is necessary to compensatefor leakage in order to maintain the vacuum level. Sicartridges can deliver moderate vacuum levels downto 75 -kPa.P6010 SiRecommended operating rangeMaximum vacuum levelFeed pressure0–70 -kPa75 -kPa0.4–0.6 MPaLPIAB L-pumps are designed and built to provide extravacuum flow. They are highly recommended forhandling porous materials such as cardboard and forhigh-volume evacuation in, for example, mixers orfast-cycling systems where it is necessary tocompensate for leakage in order to maintain thevacuum.L MINIRecommended operating rangeMaximum vacuum levelFeed pressureL CLASSICRecommended operating rangeMaximum vacuum levelFeed pressure20–70 -kPa75 -kPa0.6 MPa20–70 -kPa75 -kPa0.6 MPa22 Specifications subject to change without notice.


VACUUM PUMPSMPIAB M-pumps have been developed to perform welleven at low feed pressures. They are thus ideal whenpressures in compressed air lines are low orfluctuating. M-pumps are recommended insituations where you need good flow and a high-levelvacuum. This is the most frequently used type ofpump. They are used in most industrial vacuumpump applications.M MINIRecommended operating rangeMaximum vacuum levelFeed pressureM CLASSICRecommended operating rangeMaximum vacuum levelFeed pressure0–80 -kPa81 -kPa0.38–0.6 MPa0–90 -kPa91 -kPa0.34–0.6 MPaXPIAB X-pumps have been developed to provideexcellent flow and deep vacuum. They arerecommended in applications where a deep vacuumis required in, for example, high-speed feeders inpackaging machines and different types ofprocesses. Moreover, X-pumps can be driven by lowfeed pressures, a distinct advantage whenpressures in compressed air lines are low orfluctuating.X MINIRecommended operating rangeMaximum vacuum levelFeed pressure70–94 -kPa94 -kPa0.4–0.6 MPaVacuum pumpsHPIAB H-pumps provide very high vacuum, and theyare recommended in applications with little or noleakage, such as in laboratory applications and inother processes requiring high vacuum levels.H CLASSICRecommended operating rangeMaximum vacuum levelFeed pressure15 to 5 mbar abs5 mbar abs0.6 MPaRECOMMENDED OPERATING RANGEBi0–83 -kPaSi/L0–75 -kPaPi/M0–90 -kPaX70–94 -kPaH15–5 mbar abs 100 -kPa0 10 20 30 40 50 60 70 80 90 100a) Pump type,b) Vacuum level -kPaSpecifications subject to change without notice. 23


VACUUM PUMPSVACUUM FLOW AT RECOMMENDED FEED PRESSUREPumpseriesModel/DesignMaxvacuumFeedpressureVacuum flow (Nl/s) at different vacuum levels (-kPa)-kPa MPa 0 10 20 30 40 50 60 70 80 90P2010 P2010 83 0.18 0.23 0.15 0.060 0.040 0.035 0.023 0.013 0.006 – –P3010 P3010 Pi12-3 90 0.314 1.4 0.60 0.44 0.27 0.19 0.14 0.10 0.060 0.030 –P6010 P6010 Pi48-3X1 90 0.30 5.6 2.5 1.8 1.1 0.65 0.50 0.35 0.25 0.10 –P6010 P6010 Si32-3X1 75 0.60 6.0 3.5 2.6 1.7 0.90 0.60 0.50 0.35 – –L MINI L7 75 0.60 0.72 0.49 0.29 0.25 0.20 0.16 0.10 0.067 – –L MINI L14 75 0.60 1.5 1.0 0.57 0.45 0.39 0.32 0.24 0.13 – –L MINI L28 75 0.60 2.6 1.7 1.1 0.89 0.74 0.55 0.36 0.17 – –L MINI L56 75 0.60 5.1 3.5 2.0 1.7 1.4 1.1 0.81 0.43 – –L CLASSIC L25 75 0.60 6.1 3.3 2.2 1.4 0.81 0.64 0.45 0.29 – –L CLASSIC L50 75 0.60 10.9 5.7 3.8 2.5 1.4 1.1 0.80 0.48 – –L CLASSIC L100 75 0.60 16.5 9.6 7.5 5.0 2.9 2.3 1.6 0.95 – –L CLASSIC MP L150 75 0.60 29 16.2 12.0 7.5 3.8 2.7 1.7 0.76 – –L CLASSIC MP L200 75 0.60 38 23.0 16.1 11.2 6.5 4.9 3.0 1.1 – –L CLASSIC MP L300 75 0.60 46 30 22.8 14.7 9.0 7.1 5.2 3.1 – –L CLASSIC MP L400 75 0.60 51 39 28 16.4 11.9 9.5 6.7 4 – –M MINI M5L 81 0.38 0.58 0.30 0.22 0.18 0.14 0.10 0.080 0.040 0.010 –M MINI M10L 81 0.38 1.1 0.57 0.39 0.35 0.30 0.21 0.12 0.060 0.020 –M MINI M20L 81 0.38 2.0 1.2 0.76 0.67 0.53 0.41 0.33 0.19 0.020 –M CLASSIC M25L 91 0.34 5.9 2.7 1.8 1.2 0.75 0.51 0.38 0.28 0.11 0.020M MINI M40L 81 0.38 4.0 2.2 1.4 1.2 1.0 0.71 0.43 0.19 0.050 –M CLASSIC M50L 91 0.34 10.3 4.9 3.5 2.2 1.3 1.0 0.80 0.50 0.19 0.010M CLASSIC M100L 91 0.34 13.6 8.2 5.8 3.5 2.4 1.9 1.4 1.0 0.48 0.010M CLASSIC MP M150L 91 0.34 26 13.8 10.3 6.5 3.8 2.9 2.2 1.5 0.67 0.050M CLASSIC MP M200L 91 0.34 30 17.3 12.5 7.9 5.0 3.9 2.9 2.1 0.95 0.10M CLASSIC MP M300L 91 0.34 46 27 20.1 12.8 7.6 6.0 4.5 3.2 1.3 0.19M CLASSIC MP M400L 91 0.34 56 35 24.7 15.2 10.0 7.6 5.7 3.8 1.6 0.19M MAXI MLL200 91 0.60 48 27 18.1 9.5 4.8 3.3 2.4 1.1 0.48 0.010M MAXI MLL400 91 0.60 92 52 35 18.4 9.2 6.4 4.6 2.2 0.92 0.020M MAXI MLL800 91 0.60 176 99 67 35 17.6 12.3 8.8 4.2 1.8 0.040M MAXI MLL1200 91 0.60 255 143 97 51 26 17.9 12.8 6.1 2.6 0.050X MINI X5L 93 0.40 0.48 0.24 0.12 0.11 0.10 0.086 0.071 0.057 0.030 0.006X MINI X10L 93 0.40 0.76 0.35 0.24 0.21 0.16 0.13 0.10 0.070 0.040 0.010X MINI X20L 93 0.40 1.9 1.0 0.50 0.44 0.38 0.30 0.25 0.17 0.10 0.020X MINI X40L 93 0.40 3.2 1.5 1.0 0.90 0.70 0.60 0.50 0.40 0.17 0.038H CLASSIC H40 99.8 0.60 2.8 2.1 1.5 0.90 0.40 0.30 0.20 0.14 0.10 0.095H CLASSIC H120 100.8 0.60 8.4 6.6 4.7 2.7 1.5 1.2 0.86 0.62 0.43 0.10H CLASSIC MP H240 100.8 0.60 16.8 12.6 8.9 5.0 2.9 2.3 1.8 1.2 0.86 0.19H CLASSIC MP H480 100.8 0.60 34 26 18.2 10.3 5.9 4.9 3.4 2.3 1.7 0.48P2010 P2010 83 0.18 0.23 0.15 0.060 0.040 0.035 0.023 0.013 0.006 – –P3010 P3010 Pi12-3 90 0.314 1.4 0.60 0.44 0.27 0.19 0.14 0.10 0.060 0.030 –P6010 P6010 Pi48-3X1 90 0.30 5.6 2.5 1.8 1.1 0.65 0.50 0.35 0.25 0.10 –24 Specifications subject to change without notice.


VACUUM PUMPSEVACUATION TIME AT RECOMMENDED FEED PRESSUREPumpseriesModel/DesignFeedpressureAir consumptionEvacuation time (s/l) to reach different vacuum levels (-kPa)MPa Nl/s 10 20 30 40 50 60 70 80 90P2010 P2010 0.18 0.14 0.50 1.4 3.9 6.4 10.0 16.0 28 51 –P3010 P3010 Pi12-3 0.314 0.47 0.080 0.23 0.49 1.0 1.7 2.6 3.9 6.3 –P6010 P6010 Pi48-3X1 0.30 2.0 0.020 0.060 0.12 0.30 0.45 0.70 1.0 1.6 4.0P6010 P6010 Si48-3X1 0.60 1.75 0.020 0.050 0.10 0.18 0.33 0.53 0.80 – –L MINI L7 0.60 0.49 0.093 0.31 0.72 1.2 1.8 2.6 3.8 – –L MINI L14 0.60 0.98 0.064 0.17 0.36 0.59 0.88 1.3 1.8 – –L MINI L28 0.60 2.0 0.047 0.11 0.20 0.32 0.46 0.69 1.1 – –L MINI L56 0.60 4.0 0.023 0.053 0.10 0.16 0.23 0.33 0.50 – –L CLASSIC L25 0.60 1.8 0.042 0.074 0.12 0.21 0.36 0.56 0.88 – –L CLASSIC L50 0.60 3.5 0.015 0.033 0.060 0.11 0.19 0.29 0.45 – –L CLASSIC L100 0.60 7.0 0.008 0.018 0.033 0.060 0.10 0.15 0.23 – –L CLASSIC MP L150 0.60 10.5 0.005 0.012 0.021 0.040 0.070 0.12 0.22 – –L CLASSIC MP L200 0.60 14.0 0.004 0.009 0.016 0.030 0.050 0.070 0.13 – –L CLASSIC MP L300 0.60 21.0 0.004 0.008 0.013 0.020 0.030 0.050 0.080 – –L CLASSIC MP L400 0.60 28 0.004 0.007 0.011 0.020 0.030 0.040 0.060 – –M MINI M5L 0.38 0.38 0.20 0.61 1.2 1.8 2.6 3.8 5.9 11.1 –M MINI M10L 0.38 0.76 0.13 0.31 0.57 0.90 1.3 2.0 3.2 7.1 –M MINI M20L 0.38 1.5 0.052 0.14 0.26 0.42 0.64 1.0 1.7 3.7 –M CLASSIC M25L 0.34 1.9 0.023 0.058 0.12 0.23 0.40 0.64 0.99 1.6 3.9M MINI M40L 0.38 3.0 0.030 0.074 0.13 0.21 0.32 0.50 0.95 1.6 –M CLASSIC M50L 0.34 3.7 0.014 0.033 0.062 0.12 0.21 0.33 0.50 0.82 2.5M CLASSIC M100L 0.34 7.5 0.015 0.027 0.045 0.080 0.12 0.18 0.26 0.43 1.2M CLASSIC MP M150L 0.34 11.3 0.007 0.014 0.025 0.050 0.075 0.11 0.17 0.28 0.76M CLASSIC MP M200L 0.34 15.1 0.005 0.011 0.021 0.040 0.060 0.090 0.13 0.21 0.54M CLASSIC MP M300L 0.34 22.6 0.004 0.009 0.015 0.030 0.040 0.060 0.090 0.14 0.36M CLASSIC MP M400L 0.34 30 0.003 0.006 0.011 0.020 0.030 0.050 0.070 0.11 0.29M MAXI MLL200 0.60 14.0 0.003 0.008 0.014 0.030 0.060 0.10 0.16 0.29 0.82M MAXI MLL400 0.60 28 0.0015 0.004 0.007 0.015 0.030 0.050 0.080 0.15 0.41M MAXI MLL800 0.60 56 0.0008 0.0018 0.0035 0.008 0.014 0.024 0.040 0.072 0.2M MAXI MLL1200 0.60 84 0.0005 0.0012 0.0023 0.0052 0.009 0.016 0.027 0.048 0.14X MINI X5L 0.40 0.39 0.17 0.82 1.7 2.7 3.9 5.4 7.4 10.6 22.5X MINI X10L 0.40 0.79 0.11 0.47 0.94 1.5 2.2 3.1 4.3 6.6 14.0X MINI X20L 0.40 1.6 0.055 0.20 0.40 0.65 0.97 1.4 1.9 2.7 5.1X MINI X40L 0.40 3.1 0.038 0.12 0.22 0.33 0.48 0.68 1.2 2.2 3.2H CLASSIC H40 0.60 2.6 0.032 0.075 0.15 0.32 0.64 1.1 1.7 2.6 3.9H CLASSIC H120 0.60 7.6 0.018 0.033 0.060 0.11 0.18 0.27 0.42 0.62 1.3H CLASSIC MP H240 0.60 15.2 0.006 0.015 0.030 0.060 0.10 0.15 0.22 0.32 0.64H CLASSIC MP H480 0.60 30 0.004 0.008 0.016 0.030 0.050 0.080 0.11 0.16 0.33P2010 P2010 0.18 0.14 0.50 1.4 3.9 6.4 10.0 16.0 28 51 –P3010 P3010 Pi12-3 0.314 0.47 0.080 0.23 0.49 1.0 1.7 2.6 3.9 6.3 –P6010 P6010 Pi48-3X1 0.30 2.0 0.020 0.060 0.12 0.30 0.45 0.70 1.0 1.6 4.0Vacuum pumpsSpecifications subject to change without notice. 25


VACUUM PUMPSRESISTANCE OF VARIOUS MATERIALSResistance PA PPS POM ABS PTFE AL Nitrile rubber NBR EPDM rubber Viton®fluoroelastomers *)Weather, ozone — +++ + ++ +++ ++ + +++ +++Heat, aging ++ +++ ++ + +++ +++ ++ ++ +++Oil, petrol ++ +++ ++ + +++ + +++ — +++Hydrolysis — +++ ++ + +++ +++ ++ ++ ++Acid and alkali + +++ + — +++ — ++ +++ ++Acetone +++ +++ +++ — +++ +++ — +++ —Ammonia + ++ — — +++ ++ + +++ —Amyl alcohol +++ +++ +++ — +++ ++ ++ +++ ++Benzene +++ +++ +++ — +++ ++ — — +++Butanol — +++ +++ +++ +++ ++ ++ ++ +++Cyclohexane +++ +++ +++ — +++ +++ ++ — +++Ethanol +++ +++ +++ ++ +++ ++ + +++ +++Ethyl acetate +++ +++ +++ — +++ ++ — ++ —Hexane ++ +++ +++ — +++ +++ +++ — +++Carbon tetrachloride — +++ ++ — +++ — — — +++Chlorobenzene — +++ — — +++ +++ — — +++Chloroform +++ +++ +++ — +++ + — — +++Methanol ++ +++ +++ — +++ ++ +++ +++ +Methylene chloride + +++ ++ — +++ + — ++ +++Methyl ethyl ketone, MEK +++ +++ + — +++ ++ — +++ —NaOH +++ +++ + + +++ — ++ +++ ++Propanol — +++ +++ ++ +++ ++ +++ +++ +++Sulphuric acid — +++ — ++ +++ — + ++ +++Tetrahydrofuran +++ +++ +++ — +++ — — ++ —Tetrachlorethylene +++ +++ +++ — +++ — — — +++Toulene +++ +++ + — +++ +++ — — +++Trichlorethane + +++ +++ — +++ — — — +++Trichlorethylene + +++ — — +++ — — — +++Xylene +++ +++ +++ — +++ ++ — — +++Acetic acid — +++ — — +++ + + +++ +++++ Recommended++ Good, minor chemical attach+ Limited, moderate chemical attack, limited service— Not recommended*) Viton® is a registered trademark of DuPont Performance Elastomers.MATERIALSPA =PPPS =POM =ABS =PTFE =AL =NBR =Polyamide, Nylon®‚ for exampleComposite, Polyphenylene sulphideAcetal plastic, Polyoxymethylene, Delrin®‚ andHostaform®‚ for exampleThermoplasticPolytetrafluoroethylene, Teflon®‚ for exampleAluminiumNitrile26 Specifications subject to change without notice.


VACUUM PUMPSRECOMMENDED HOSE DIMENSIONS IN MM (INTERNAL DIAMETER)Pump design Compressed air Vacuum ExhaustP2010 >2.5 >2.5 >8P3010 > 4 > 8 > 10P6010 Pi48-3X1 >6 >12 >15P6010 Si32-3X1 >4 >12 >15P6010 Pi48-3X2 >8 >15 >19P6010 Si32-3X2 >6 >15 >19P6010 Pi48-3X3 >10 >19 >22P6010 Si32-3X3 >8 >19 >22P6010 Pi48-3X4 >10 >22 >25P6010 Si32-3X4 >8 >22 >25M5L > 2 > 5 > 8M10L, L7 > 2 > 8 > 10M20L, L14 > 4 > 10 > 12M25L / L25 / L28 > 4 > 12 > 12M40L > 6 > 12 > 15M50L / L50 / L56 > 6 > 15 > 15M100L / L100 > 8 > 19 > 22M150L > 8 > 25 > 32MLL200 / L200 > 10 > 32 > 40M300L / L300 > 12 > 40 > 60MLL400 / M400L / L400 > 12 > 40 > 60MLL800 > 15 > 50 > 75MLL1200 > 20 > 75 > 100Applies to hoses up to 2 m long.Vacuum pumpsIMPORTANT!A very important part of the vacuum system iscorrectly dimensioned hoses and couplings. Toobtain the highest possible performance from eachvacuum pump, please consult the table above.Specifications subject to change without notice. 27


VACUUM PUMPSMODELSP2010The PIAB P2010 uses the patented COAX® technology and is a small “inline” ejectorthat can be directly mounted between the compressed-air hose and the vacuum hose.The ejector works best at low feed pressures, has a very low weight and can be easilycleaned and exchanged whenever needed. The main area of usage is in ”pick-andplace”applications handling small components such as, for example, those of theelectronics industry.P3010The PIAB P3010 uses the COAX® technology, which makes it small, robust and easy toinstall. This vacuum pump consists of a cassette with integrated nozzles, non-returnvalves, silencers and filters for compressed air and vacuum. The P3010 vacuum pumpseries includes control and monitoring functions such as solenoid valves, vacuumswitches and quick-release modules. The PIAB P3010 enables you to decide foryourself the functions you need, and you can eliminate all costly, needless refinements.The performance can therefore be upgraded in pace with your changing needs.P3010 AVMThe P3010 AVM is a compact and modular vacuum pump with integrated COAX®technology and Automatic Vacuum Management functionality. It has been developed forhandling parts in applications with the highest demand on performance, availability,energy saving, flexibility and reliability. Highly automated systems with industrial robotsand machines used for handling sheet metal, plastic parts and corrugated cardboardmaterial are typical examples. The compact size and modular, in-line design simplifyinstallation and maintenance. The integrated COAX® guarantees energy efficient andreliable vacuum performance even at really low feed pressures.PMAT COAX®The PMAT low profile Pi12-2 COAX® is a pump unit equipped with a built-in blow-offcheck valve for decentralized vacuum systems. The mounting fits standard robot endof-armtooling found in the automotive industry (ball joint and lock-pin connections). Itis available with a T-slot connection for the suction cup or a G3/8” female thread.P6010Based upon the patented COAX® technology, the PIAB P6010 provides up to 40% moreflow than conventional vacuum pumps, while still reducing overall energy consumption.A durable, maintenance-free, design makes the P6010 ideally suited for automatedmaterial handling and other manufacturing processes in the automotive, robotic,graphics and packaging industries. The P6010 provides powerful, whisper-quiet, andnon-heat generating suction at extremely low feed pressures. Additionally, the pump’scompact size makes it possible to mount closer to the point of suction, thus reducingcompressed-air requirements and saving energy.28 Specifications subject to change without notice.


VACUUM PUMPSP6010 AVMPIAB P6010 (see above) is available with an integrated control option for highlyautomated systems – the Automatic Vacuum Management (AVM). This option canreduce air consumption by up to 90%, when compared to continuously operatingsystems. Featuring a vacuum sensing capability, the AVM instantly shuts off airconsumption when the set vacuum level is reached. When the vacuum is no longerrequired after a completed work cycle, the product release time is reduced by a highcapacity positive pressure blow-off function. The AVM’s high capacity blow-off functionmakes it ideal for handling non-leaking parts, such as glass and sheet metal.P6010 PCCPIAB P6010 (see above) is available with an integrated control option designed to finetunevacuum pump performance and lower energy consumption – the PIAB CruiseControl (PCC). Offering many advantages for leak-prone materials, such as paper,plastic bags and corrugated cardboard, PCC is ideally suited for automated materialhandling processes in the graphics and packaging industries. PIAB’s PCC automaticallymaintains a pre-set level of vacuum to ensure that a consistent vacuum level, andtherefore a secure grip, is provided at the suction point. This feature is reliable duringfluctuations in vacuum pressure, caused by product variations or changes in cycle time.Vacuum pumpsMINIThese are small and lightweight vacuum pumps with large capacity that cancompensate for leakages. The MINI pumps are available with different characteristics,accessories and designs so that they can be adapted to different applications. The MINIpumps can be mounted onto various types of bottom plates and, through this, be givennumerous connection possibilities. They can also be fitted with valves and/or a vacuumsensor. By doing so, a complete system (Mini System) is created, and such a systemcan, when necessary, be dimensioned for larger flows. To the MINI vacuum pumps thereare connection plates for different installation alternatives.CLASSICPIAB CLASSIC vacuum pump series in various sizes and characteristics. Large capacitydespite its small size and low weight. Suitable for a great number of applications as aseparate vacuum source or as the base unit of a system with medium capacityrequirements. Flexible and simple design that can be provided with an energy-savingsystem.CLASSIC MPA compact vacuum pump for large flows and deep vacuum levels, that is especiallysuitable when high productivity and secure function are required in mounting, packagingand automation processes. This vacuum pump is easy to control and very reliable.Because it is almost maintenance-free the operation stoppages are negligible. Toimprove the economy even more it can be provided with an energy-saving system.MAXILarge vacuum pump for applications where large volumes need to be evacuated or tocompensate for large leakage flows. Can also be used for vacuum conveying. May alsobe provided with an energy-saving system and central exhaust.Specifications subject to change without notice. 29


VACUUM PUMPS P2010P2010 BI03-2 COAX® patented technology Low operating feed pressure Miniature size Inline design Short cycle timesTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 61–64Temperature range ºC -10–50Weight g 15.3MaterialPA, NBR, Al, SS, POM, CuZn, PSCVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 -kPa0.11 0.10 0.17 0.10 0.040 0.027 0.013 — — — 500.18 0.14 0.23 0.15 0.060 0.040 0.035 0.023 0.013 0.006 830.22 0.17 0.27 0.19 0.090 0.040 0.025 0.020 0.010 0.005 82EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 -kPa0.11 0.10 0.70 2.9 5.9 11.0 28 — — — 500.18 0.14 0.50 1.4 3.9 6.4 10.0 16.0 28 51 830.22 0.17 0.40 1.1 3.3 6.4 11.0 18.0 32 62 820.300.21 MPa0.17 MPa0.1 MPa800.21 MPa0.17 MPa0.1 MPa0.25700.2060500.15400.1030200.05100.0001020 30 40 50Vacuum flow607001020 30 40 50 60Evacuation time708030 Specifications subject to change without notice.


VACUUM PUMPS P2010ORDERING INFORMATIONDescriptionArt. No.Vacuum pump P2010 0107996Vacuum pumpsP2010Specifications subject to change without notice. 31


VACUUM PUMPS P2010P2010 BI03-2 WITH DIN-RAIL COAX® patented technology Low operating feed pressure Low weight Miniature size Inline design Short cycle times DIN-rail mounting Quick and easy mountingTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 61-64Temperature range ºC -10–50MaterialPA, NBR, Al, SS, POM, PP, CuZn, PSCTECHNICAL DATA, SPECIFICDescription Unit Value0110145 0110348Weight g 2.5 17.8VACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 -kPa0.11 0.10 0.17 0.10 0.040 0.027 0.013 — — — 500.18 0.14 0.23 0.15 0.060 0.040 0.035 0.023 0.013 0.006 830.22 0.17 0.27 0.19 0.090 0.040 0.025 0.020 0.010 0.005 82EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 -kPa0.11 0.10 0.70 2.9 5.9 11.0 28 — — — 500.18 0.14 0.50 1.4 3.9 6.4 10.0 16.0 28 51 830.22 0.17 0.40 1.1 3.3 6.4 11.0 18.0 32 62 820.300.21 MPa0.17 MPa0.1 MPa800.21 MPa0.17 MPa0.1 MPa0.25700.2060500.15400.1030200.05100.0001020 30 40 50Vacuum flow607001020 30 40 50 60Evacuation time708032 Specifications subject to change without notice.


VACUUM PUMPS P2010ORDERING INFORMATIONDescriptionArt. No.Vacuum pump P2010, DIN 0110348DIN rail 35 mm P2010 0110145Vacuum pumpsP2010Specifications subject to change without notice. 33


VACUUM PUMPS P2010QUICK-RELEASE P2010FEATURES Flexible Quick-Release volume Electrical/Pneumatic Low weight Miniature size Inline design Short cycle times Quick and easy mountingTECHNICAL DATATECHNICAL DATA, SPECIFICThe user is advised to increase the feed pressure by0.05 MPa to attain correct feed pressure in thepump.Description Unit ValueFeed pressure, max. MPa 0.7Temperature range ºC -5–50MaterialPA, NBR, Al, SS, POM, CuZn, PSC, PEDescription Unit Value0110350 0110351 0110352 0110353Weight g 26 29 50 52Volume, Quick-Release cm 3 0.9 2.3 0.9 2.3Voltage V DC 24 (-5%+10%) 24 (-5%+10%)Response time ms 8-10 8-10Display LED LEDPower W 1.3 1.334 Specifications subject to change without notice.


VACUUM PUMPS P2010ORDERING INFORMATIONDescriptionArt. No.B, C Quick-Release 0 pneumatic, P2010 0110350B, D Quick-Release 3 pneumatic, P2010 0110351A, C Quick-Release 0 electric, P2010 0110352A, D Quick-Release 3 electric, P2010 0110353— Cable to solenoid valve 2 m, 1 pc. 0110157Vacuum pumpsP2010Specifications subject to change without notice. 35


VACUUM PUMPS P2010BLOW-OFF P2010 Blow-off with inline design Short cycle times Low weight Miniature size Inline design Quick and easy mountingThe user is advised to increase the feed pressure by0.05 MPa to attain correct feed pressure in thepump.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Temperature range ºC -5–50Weight g 63MaterialPA, NBR, Al, SS, PE, CuZnVoltage V DC 24 (-5%+10%)Response time ms 8-10Display LED x 2Power W 1.336 Specifications subject to change without notice.


VACUUM PUMPS P2010ORDERING INFORMATIONDescriptionArt. No.Blow-off unit P2010 0110349Cable to solenoid valve 2 m, 1 pc. 0110157Vacuum pumpsP2010Specifications subject to change without notice. 37


VACUUM PUMPS P3010P3010 WITH CONNECTIONS 3 X 1/8" NPSF COAX® patented technology Low operating feed pressure Fast cycle times Inline design Modular functions availableTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 66–68Temperature range ºC -10–50Weight g 110MaterialPP, PA, NBR, Al, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 0.79 1.6 1.0 0.50 0.41 0.36 0.28 0.17 0.050 0.010 – 830.314 0.47 1.4 0.60 0.44 0.27 0.19 0.14 0.10 0.060 0.030 – 900.17 0.30 0.90 0.40 0.22 0.15 0.070 – – – – – 49EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 0.79 0.060 0.17 0.37 0.65 1.0 1.4 2.4 9.0 – 830.314 0.47 0.080 0.23 0.49 1.0 1.7 2.6 3.9 6.3 – 900.17 0.30 0.15 0.46 1.0 2.0 – – – – – 491.50.6 MPa0.314 MPa0.17 MPa300.6 MPa0.314 MPa0.17 MPa1.2250.9s/l20Nl/s150.6100.350.001020 30 40 50 60-kPaVacuum flow70809001020 30 40 50 60 70-kPaEvacuation time809038 Specifications subject to change without notice.


VACUUM PUMPS P3010ORDERING INFORMATIONDescriptionArt. No.Vacuum pump P3010 Pi12-3, conn. 3 x 1/8” NPSF 01042791 3239.5 2x 16.53x1/8"NPSF2 2 281/8"NPSF1313.838.555.29.44.155.716.67 22.5100145.5ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit P3010, NBR sealings 0104201Vacuum pumpsP3010Specifications subject to change without notice. 39


VACUUM PUMPS P3010P3010 WITH CONNECTIONS 6 X 1/8" NPSF COAX® patented technology Low operating feed pressure Fast cycle times Inline design Modular functions availableTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 66–68Temperature range ºC -10–50Weight g 257MaterialPP, PA, NBR, Al, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 1.6 3.2 2.0 1.0 0.82 0.72 0.56 0.34 0.10 0.020 – 830.314 0.94 2.8 1.2 0.88 0.54 0.38 0.28 0.20 0.12 0.060 – 900.17 0.60 1.8 0.80 0.44 0.30 0.14 – – – – – 49EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 1.6 0.030 0.085 0.19 0.33 0.50 0.70 1.2 4.5 – 830.314 0.94 0.040 0.12 0.25 0.50 0.85 1.3 2.0 3.2 – 900.17 0.60 0.075 0.23 0.50 1.0 – – – – – 493.00.6 MPa0.314 MPa0.17 MPa100.6 MPa0.314 MPa0.17 MPa2.582.06Nl/s1.51.0s/l40.520.001020 30 40 50 60-kPaVacuum flow70809001020 30 40 50 60 70-kPaEvacuation time809040 Specifications subject to change without notice.


VACUUM PUMPS P3010ORDERING INFORMATIONDescriptionArt. No.Vacuum pump P3010 Pi12-3x2, conn. 6 x 1/8” NPSF 01042811 3223 3x 16.52 2 2 26x1/8"NPSF10228379.251/8"NPSF1313.85.27 22.5 59.251004.155.716.6Vacuum pumpsP3010145.5ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit P3010, NBR sealings 0104201Specifications subject to change without notice. 41


VACUUM PUMPS P3010P3010 WITH QUICK-RELEASE INCLUDING TANK 3 CM 3 COAX® patented technology Low operating feed pressure Fast cycle times Inline design Modular functions availableTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 66–68Temperature range ºC -10–50Weight g 168Volume quick-release cm 3 3MaterialPP, PA, NBR, Al, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 0.79 1.6 1.0 0.50 0.41 0.36 0.28 0.17 0.050 0.010 – 830.314 0.47 1.4 0.60 0.44 0.27 0.19 0.14 0.10 0.060 0.030 – 900.17 0.30 0.90 0.40 0.22 0.15 0.070 – – – – – 49EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 0.79 0.060 0.17 0.37 0.65 1.0 1.4 2.4 9.0 – 830.314 0.47 0.080 0.23 0.49 1.0 1.7 2.6 3.9 6.3 – 900.17 0.30 0.15 0.46 1.0 2.0 – – – – – 491.50.6 MPa0.314 MPa0.17 MPa300.6 MPa0.314 MPa0.17 MPa1.2250.9s/l20Nl/s150.6100.350.001020 30 40 50 60-kPaVacuum flow70809001020 30 40 50 60 70-kPaEvacuation time809042 Specifications subject to change without notice.


VACUUM PUMPS P3010ORDERING INFORMATIONDescriptionArt. No.Vacuum pump P3010 Pi12-3, conn. push-in 8 and 6 mm, QR incl. tank 3 cm³ 01042821 3220.536.5G1/8" 6QRT282876.561313.25.29.44.157 22.5 59.25100145.55.716.6Vacuum pumpsP3010ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit P3010, NBR sealings 0104201Specifications subject to change without notice. 43


VACUUM PUMPS P3010P3010 WITH QUICK-RELEASE AND TANK 30 CM 3 COAX® patented technology Low operating feed pressure Fast cycle times Inline design Modular functions availableTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 66–68Temperature range ºC -10–50Weight g 207Volume quick-release cm 3 33MaterialPP, PA, NBR, Al, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 0.79 1.6 1.0 0.50 0.41 0.36 0.28 0.17 0.050 0.010 – 830.314 0.47 1.4 0.60 0.44 0.27 0.19 0.14 0.10 0.060 0.030 – 900.17 0.30 0.90 0.40 0.22 0.15 0.070 – – – – – 49EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 0.79 0.060 0.17 0.37 0.65 1.0 1.4 2.4 9.0 – 830.314 0.47 0.080 0.23 0.49 1.0 1.7 2.6 3.9 6.3 – 900.17 0.30 0.15 0.46 1.0 2.0 – – – – – 491.50.6 MPa0.314 MPa0.17 MPa300.6 MPa0.314 MPa0.17 MPa1.2250.9s/l20Nl/s150.6100.350.001020 30 40 50 60-kPaVacuum flow70809001020 30 40 50 60 70-kPaEvacuation time809044 Specifications subject to change without notice.


VACUUM PUMPS P3010ORDERING INFORMATIONDescriptionArt. No.Vacuum pump P3010 Pi12-3, conn. push-in 8 and 6 mm, QR and tank 30 cm³ 01042831 3220.56QRT8101.228615.29.44.155.7313.216.6Vacuum pumpsP3010722.5 59.25100145.5ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit P3010, NBR sealings 0104201Specifications subject to change without notice. 45


VACUUM PUMPS P3010P3010 WITH QUICK-RELEASE AND TANK 60 CM 3 COAX® patented technology Low operating feed pressure Fast cycle times Inline design Modular functions availableTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 66–68Temperature range ºC -10–50Weight g 320Volume quick-release cm 3 63MaterialPP, PA, NBR, Al, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 1.6 3.2 2.0 1.0 0.82 0.72 0.56 0.34 0.10 0.020 – 830.314 0.94 2.8 1.2 0.88 0.54 0.38 0.28 0.20 0.12 0.060 – 900.17 0.60 1.8 0.80 0.44 0.30 0.14 – – – – – 49EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 1.6 0.030 0.085 0.19 0.33 0.50 0.70 1.2 4.5 – 830.314 0.94 0.040 0.12 0.25 0.50 0.85 1.3 2.0 3.2 – 900.17 0.60 0.075 0.23 0.50 1.0 – – – – – 493.00.6 MPa0.314 MPa0.17 MPa100.6 MPa0.314 MPa0.17 MPa2.582.06Nl/s1.51.0s/l40.520.001020 30 40 50 60-kPaVacuum flow70809001020 30 40 50 60 70-kPaEvacuation time809046 Specifications subject to change without notice.


VACUUM PUMPS P3010ORDERING INFORMATIONDescriptionArt. No.Vacuum pump P3010 Pi12-3x2, conn. 6 x 1/8" NSPF, QR and tank 60 cm³ 01042841 3220.56210QRT61233813.2126.2Vacuum pumpsP30105.29.44.1516.65.77 22.5 59.2566100204.5ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit P3010, NBR sealings 0104201Specifications subject to change without notice. 47


VACUUM PUMPS P3010P3010 WITH ENERGY-SAVING SYSTEM COAX® patented technology Low operating feed pressure Fast cycle times Inline design Modular functions availableTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 66–68Temperature range ºC -10–50Weight g 300MaterialPP, PA, NBR, Al, SSHysteresis kPa 10 000 000VACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 1.6 3.2 2.0 1.0 0.82 0.72 0.56 0.34 0.10 0.020 – 830.314 0.94 2.8 1.2 0.88 0.54 0.38 0.28 0.20 0.12 0.060 – 900.17 0.60 1.8 0.80 0.44 0.30 0.14 – – – – – 49EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 1.6 0.030 0.085 0.19 0.33 0.50 0.70 1.2 4.5 – 830.314 0.94 0.040 0.12 0.25 0.50 0.85 1.3 2.0 3.2 – 900.17 0.60 0.075 0.23 0.50 1.0 – – – – – 493.00.6 MPa0.314 MPa0.17 MPa100.6 MPa0.314 MPa0.17 MPa2.582.06Nl/s1.51.0s/l40.520.001020 30 40 50 60-kPaVacuum flow70809001020 30 40 50 60 70-kPaEvacuation time809048 Specifications subject to change without notice.


VACUUM PUMPS P3010ORDERING INFORMATIONDescriptionArt. No.Vacuum pump P3010 Pi12-3x2, conn. 4x1/8" NPSF, ES 01062241 3223 3x 16.516.66x1/8"NPSF2222228413397Vacuum pumpsP3010675.29.44.155.713.24922.5 59.2562200.5100ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit P3010, NBR sealings 0104201Specifications subject to change without notice. 49


VACUUM PUMPS P3010P3010 PUMP MODULES COAX® patented technology Low operating feed pressure Fast cycle times Inline design Modular functions availableTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 66–68Temperature range ºC -10–50MaterialPP, PA, Al, SS, NBRTECHNICAL DATA SPECIFICDescription Unit Value0104657 0104656 0106183 0104658Weight g 74 63 63 78VACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 0.79 1.6 1.0 0.50 0.41 0.36 0.28 0.17 0.050 0.010 – 830.314 0.47 1.4 0.60 0.44 0.27 0.19 0.14 0.10 0.060 0.030 – 900.17 0.30 0.90 0.40 0.22 0.15 0.070 – – – – – 49EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 0.79 0.060 0.17 0.37 0.65 1.0 1.4 2.4 9.0 – 830.314 0.47 0.080 0.23 0.49 1.0 1.7 2.6 3.9 6.3 – 900.17 0.30 0.15 0.46 1.0 2.0 – – – – – 491.50.6 MPa0.314 MPa0.17 MPa300.6 MPa0.314 MPa0.17 MPa1.2250.9s/l20Nl/s150.6100.350.001020 30 40 50 60-kPaVacuum flow70809001020 30 40 50 60 70-kPaEvacuation time809050 Specifications subject to change without notice.


VACUUM PUMPS P3010ORDERING INFORMATIONDescriptionArt. No.A Vacuum pump module P3010 Pi12-3, conn. compressed air 1/8" NPSF 0104657B Vacuum pump module P3010 Pi12-3, conn. compressed air push-in Ø6 mm 0104656B Vacuum pump module P3010 Pi12-3, conn. compressed air push-in Ø6 mm, non-return valve 0106183C Vacuum pump module P3010 Pi12-3, extra 01046581 31 31 31 3221/8"NPSF13.815.223830.713.2615.22389.44.159.44.1530.75.75.7722.5 59.25100145.5A722.5 59.25100145.5BVacuum pumpsP30101 31 32282530.7100138.5CORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit P3010, NBR sealings 0104201Specifications subject to change without notice. 51


VACUUM PUMPS P3010P3010 QUICK-RELEASE MODULES COAX® patented technology Inline design Modular functions availableTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Temperature range ºC -10–50MaterialAl, SS,PPS, NBR, PATECHNICAL DATA, SPECIFICDescription Unit Value0104271 0104351 0104272 0104273Quick-release volume cm 3 3 3 30 60Weight g 121 121 72 11852 Specifications subject to change without notice.


VACUUM PUMPS P3010ORDERING INFORMATIONDescriptionArt. No.A Quick-Release module P3010, vacuum connections push-in 8 and 6 mm 0104271A Quick-Release module P3010, conn. push-in 10 and 6 mm 0104351B Quick-Release tank module P3010, 30 cm³ 0104272C Quick-Release tank module P3010, 60 cm³ 0104273ABVacuum pumpsP3010CSpecifications subject to change without notice. 53


VACUUM PUMPS P3010P3010 CONNECTION MODULES COAX® patented technology In-line design Modular functions availableTECHNICAL DATADescription Unit ValueTemperature range ºC -20–80MaterialAl, PPS, NBR, CuZnTECHNICAL DATA, SPECIFICDescription Unit Value0104269 0104270 0106169Weight g 50 100 190ORDERING INFORMATIONDescriptionArt. No.A Connection module P3010, vacuum 3 x 1/8" NPSF 0104269B Connection module P3010, vacuum 6 x 1/8" NPSF 0104270C Connection module P3010, conn. G3/8" or push-in 12 mm and 2 x 1/8" NPSF 01061691539.5 2x 16.52 2 23x1/8" NPSF106x1/8" NPSF23 3x 16.516.31001030.72 2 2 22 2A16.3B1001245 333x1/8" NPSF2230.71232.8100 26.5C130.0554 Specifications subject to change without notice.


VACUUM PUMPS P3010P3010 MOUNTING RAIL Rigid and easy to mount For dynamic loadsTECHNICAL DATADescription Unit ValueTemperature range ºC -10–50Weight g 60–120MaterialAl, SSVacuum pumpsP3010ORDERING INFORMATIONDescriptionArt. No.Mounting rail P3010, one pump module 0106167Mounting rail P3010, 2 pump modules 0106162Mounting rail P3010, 3 pump modules 0106168Mounting rail P3010, 4 pump modules 01061601838A5516 217116 378716 5329 23.7575.213.2SECTION A-A2x 5.22x 5.22x 5.24x 5.2ASpecifications subject to change without notice. 55


VACUUM PUMPS P3010P3010 COMMON-FEED ADAPTERS One compressed air connection required to feedair to several pumps.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Temperature range ºC -10–50Weight g 20–40MaterialAl, PPSORDERING INFORMATIONDescriptionArt. No.Common-feed adapter P3010, 2 pump modules 0106157Common-feed adapter P3010, 3 pump modules 0106158Common-feed adapter P3010, 4 pump modules 010615956 Specifications subject to change without notice.


VACUUM PUMPS P3010P3010 EXHAUST ADAPTER Connection of exhaust air For clean environment Directed blowing airTECHNICAL DATADescription Unit ValueTemperature range ºC -10–50Weight g 8Connection, exhaustG1/4" / Ø16 mmMaterialAlORDERING INFORMATIONDescriptionArt. No.Exhaust adapter P3010 0106344Vacuum pumpsP3010Ø 16G1/4"3317.5M15 x 1Specifications subject to change without notice. 57


VACUUM PUMPS P3010P3010 AVM Pi12-3 An M12 8-pin electrical interface makesinstallation easy. COAX® multistage ejectors with built-in nonreturnvalves. Two vacuum switches. Valves for vacuum on/off and blow-off. Blow-off adjustment valve for flow-rate control. Automatic energy-saving function – can beswitched off for leaking applications. PNP or NPN with the same unit. Reversed polarity protection.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 66–68MaterialPA, NBR, Al, SS, PMMA, ABSTemperature range ºC 0–50Weight g 250Voltage VDC 24 (22-30)Flow, blow-off Nl/s 0–7.5Current consumption mA 110Current, max. output load mA 100Hysteresis kPa 6 ±1Safety classificationIP65Ripple, max. VP 1 VRMS, 50–60 HzDisplayLED indicatorsTECHNICAL DATA, SPECIFICDescription Unit Value0110307 0110308 0110309 0110313 0110314 0110315Function, on/off NO NO NO NC NC NCSignal range -kPa 30/50 30/70 50/70 30/50 30/70 50/70VACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 0.79 1.6 1.0 0.50 0.41 0.36 0.28 0.17 0.050 0.010 – 830.314 0.47 1.4 0.60 0.44 0.27 0.19 0.14 0.10 0.060 0.030 – 900.17 0.30 0.90 0.40 0.22 0.15 0.070 – – – – – 49EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 0.79 0.060 0.17 0.37 0.65 1.0 1.4 2.4 9.0 – 830.314 0.47 0.080 0.23 0.49 1.0 1.7 2.6 3.9 6.3 – 900.17 0.30 0.15 0.46 1.0 2.0 – – – – – 4958 Specifications subject to change without notice.


VACUUM PUMPS P3010ORDERING INFORMATIONDescriptionArt. No.P3010 AVM Pi12-3 NO 30/50 0110307P3010 AVM Pi12-3 NO 30/70 0110308P3010 AVM Pi12-3 NO 50/70 0110309P3010 AVM Pi12-3 NC 30/50 0110313P3010 AVM Pi12-3 NC 30/70 0110314P3010 AVM Pi12-3 NC 50/70 0110315NO = Normally open valve for vacuum on/off, NC = Normally closed valve for vacuum on/off1P28p15./813x5 510439Vacuum pumpsP301016.677ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Cable 2m 0.25 x 7 PUR with electrical connector M12 8-pin 011023814 5Specifications subject to change without notice. 59


VACUUM PUMPS P3010P3010 AVM Pi12-3 X 2 An M12 8-pin electrical interface makesinstallation easy. COAX® multistage ejectors with built-in nonreturnvalves. Two vacuum switches. Valves for vacuum on/off and blow-off. Blow-off adjustment valve for flow-rate control. Automatic energy-saving function – can beswitched off for leaking applications. PNP or NPN with the same unit. Reversed polarity protection.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 66–68MaterialPA, NBR, Al, SS, PMMA, ABSTemperature range ºC 0–50Weight g 330Voltage VDC 24 (22-30)Flow, blow-off Nl/s 0–7.5Current consumption mA 110Current, max. output load mA 100Hysteresis kPa 6 ±1Safety classificationIP65Ripple, max. VP 1 VRMS, 50–60 HzDisplayLED indicatorsTECHNICAL DATA, SPECIFICDescription Unit Value0110310 0110311 0110312 0110316 0110317 0110318Function, on/off NO NO NO NC NC NCSignal range -kPa 30/50 30/70 50/70 30/50 30/70 50/70VACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 1.6 3.2 2.0 1.0 0.82 0.72 0.56 0.34 0.10 0.020 – 830.314 0.94 2.8 1.2 0.88 0.54 0.38 0.28 0.20 0.12 0.060 – 900.17 0.60 1.8 0.80 0.44 0.30 0.14 – – – – – 49EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 1.6 0.030 0.085 0.19 0.33 0.50 0.70 1.2 4.5 – 830.314 0.94 0.040 0.12 0.25 0.50 0.85 1.3 2.0 3.2 – 900.17 0.60 0.075 0.23 0.50 1.0 – – – – – 4960 Specifications subject to change without notice.


5 5VACUUM PUMPS P3010ORDERING INFORMATIONDescriptionArt. No.P3010 AVM Pi12-3 x 2 NO 30/50 0110310P3010 AVM Pi12-3 x 2 NO 30/70 0110311P3010 AVM Pi12-3 x 2 NO 50/70 0110312P3010 AVM Pi12-3 x 2 NC 30/50 0110316P3010 AVM Pi12-3 x 2 NC 30/70 0110317P3010 AVM Pi12-3 x 2 NC 50/70 0110318NO = Normally open valve for vacuum on/off, NC = Normally closed valve for vacuum on/off1P8px26615. 25/81310432Vacuum pumpsP3010.667100ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Cable 2m 0.25 x 7 PUR with electrical connector M12 8-pin 01102385.Specifications subject to change without notice. 61


VACUUM PUMPS PMATPMAT COAX® "COAX® patented technology” means fasterresponse and lower energy consumption. Reliable even at low operating feed pressure. Equipped with a built-in blow-off valve toprovide quick release of the object. Low height Mounting possibilities with ball joint, lock pin andT-slot (suction cup).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Feed pressure, min., breakaway blow-off MPa 0.25Feed pressure, optimum COAX® MPa 0.314Air consumption, 0.314 MPa Nl/s 0.47Vacuum, 0.314 MPa -kPa 90Noise level, with load dBA 65Noise level, without load dBA 74MaterialPA, AL, Steel, Ceramic, NBRTemperature range °C -10–50Vacuum flow, max. Nl/s 0.68TECHNICAL DATA, SPECIFICDescription Unit Value0110442 0110443 0110439Weight g 214 245 292Connection, mounting Ball joint Lock pin 19 mm Ball jointConnection, suction cup G3/8" G3/8" T-slotVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.314 0.47 0.68 0.6 0.44 0.27 0.19 0.14 0.1 0.06 0.03 — 90EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.314 0.47 0.17 0.32 0.58 1.1 1.8 2.7 4 6.4 — 9062 Specifications subject to change without notice.


VACUUM PUMPS PMATORDERING INFORMATIONDescriptionArt. No.A PMAT COAX® Pi12-2, low profile, ball joint 0110442B PMAT COAX® Pi12-2, low profile, lock pin 19 mm 0110443C PMAT COAX® Pi12-2, low profile, T-slot, ball joint 011043976G3 "2x /422.10.28/8G1 "310.50.25.A25.28owf29.90.50.419B4owf29.76.Vacuum pumpsPMAT.33344.8INBl of25.2x /428.84.CSpecifications subject to change without notice. 63


VACUUM PUMPS P6010P6010 PI48-3X1 COAX®patented technology Substationally lower air consumption ascompared to conventional ejectors Modular design Available with multiple connection alternatives Low noise level Low feed pressure that ensures highrealiability even in case of pressure drops Short evacuation timeTECHNICAL DATAVACUUM FLOWSupplied with a vacuum gauge.Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 65–70Temperature range °C -10–80Weight g 1700–1800MaterialAl, PA, NBR, SS, TPEFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.22 1.62 5.0 2.0 1.5 0.90 0.55 0.45 0.26 0.07 — — 730.30 2.0 5.6 2.5 1.8 1.1 0.65 0.50 0.35 0.25 0.10 — 900.40 2.54 5.7 2.5 2.1 1.5 1.10 0.66 0.36 0.26 0.080 — 86EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.22 1.62 0.025 0.080 0.090 0.30 0.50 0.80 1.7 — — 730.30 2.0 0.020 0.060 0.12 0.30 0.45 0.70 1.0 1.6 4.0 900.40 2.54 0.020 0.055 0.11 0.18 0.29 0.59 0.90 1.7 — 86BLOW FLOWFeed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 20 40 60 70 80 90 100 110 120 130 140 kPa0.60 3.55 9.5 6.5 6.0 5.3 4.7 4.6 4.6 4.6 4.5 4.3 4.0 3.7 14060.40 MPa0.30 MPa0.22 MPa4.00.40 MPa0.30 MPa0.22 MPa100.60 MPa53.53.0842.5Nl/s32.0Nl/s621.51.0410.500100.020 30 40 50 60 70 80 9010 20 30 40 50 60 70 80 9020 20 40 60 70 80 90 100 110 120 130 140-kPaVacuum flow Evacuation time Blow flow64 Specifications subject to change without notice.


VACUUM PUMPS P6010ORDERING INFORMATION1. Housing P6010 CodeHousingP60102. Vacuum Cartridge Module P6010 Codea Cartridge module Pi48-3X1 AJb Cartridge module Pi48-3X1, non-return valve AN3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 014. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plainLACover plate NPSF thread connections, Cover plate, plainLJ5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x G3/4" 53Connections 2x G3/4", silencer 3/4" 54Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56Connections 2x 3/4" NPSF 57Connections 2x 3/4" NPSF, silencer 3/4" 58ExampleOrdering numberP6010 Pi48-3X1, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AJ 01 LA 52Vacuum pumpsP6010ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532Specifications subject to change without notice. 65


VACUUM PUMPS P6010P6010 PI48-3X2 COAX®patented technology Substationally lower air consumption ascompared to conventional ejectors Modular design Available with multiple connection alternatives Low noise level Low feed pressure that ensures highrealiability even in case of pressure drops Short evacuation timeTECHNICAL DATAVACUUM FLOWSupplied with a vacuum gauge.Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 65–70Temperature range °C -10–80Weight g 1700–1800MaterialAl, PA, NBR, SS, TPEFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.22 3.24 10.0 4.0 3.0 1.8 1.1 0.90 0.52 0.14 — — 730.30 4.0 11.2 5.0 3.6 2.2 1.3 1.0 0.70 0.50 0.20 — 900.40 5.08 11.4 5.0 4.2 3.0 2.2 1.3 0.7 0.52 0.16 — 86EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.22 3.24 0.013 0.040 0.045 0.15 0.25 0.40 0.85 — — 730.30 4.0 0.010 0.030 0.060 0.13 0.23 0.35 0.50 0.80 2.0 900.40 5.08 0.010 0.028 0.055 0.090 0.15 0.30 0.45 0.85 — 86BLOW FLOWFeed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 20 40 60 70 80 90 100 110 120 130 140 kPa0.60 7.1 19.0 13.0 12.0 10.6 9.4 9.2 9.2 9.2 9.0 8.6 8.0 7.4 140120.40 MPa0.30 MPa0.22 MPa2.00.40 MPa0.30 MPa0.22 MPa200.60 MPa101.5815Nl/ss/l61.0Nl/s420.510001020304050607080900.010 20 30 40 50 60 70 80 9050 20 40 60 70 80 90 100 110 120 130 140-kPa-kPaVacuum flow Evacuation time Blow flow66 Specifications subject to change without notice.


VACUUM PUMPS P6010ORDERING INFORMATION1. Housing P6010 CodeHousingP60102. Vacuum Cartridge Module P6010 Codea Cartridge module Pi48-3X2 AKb Cartridge module Pi48-3X2, non-return valve AO3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 014. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plainLACover plate NPSF thread connections, Cover plate, plainLJ5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x G3/4" 53Connections 2x G3/4", silencer 3/4" 54Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56Connections 2x 3/4" NPSF 57Connections 2x 3/4" NPSF, silencer 3/4" 58ExampleOrdering numberP6010 Pi48-3X2, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AK 01 LA 52Vacuum pumpsP6010ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532Specifications subject to change without notice. 67


VACUUM PUMPS P6010P6010 PI48-3X3 COAX®patented technology Substationally lower air consumption ascompared to conventional ejectors Modular design Available with multiple connection alternatives Low noise level Low feed pressure that ensures highrealiability even in case of pressure drops Short evacuation timeTECHNICAL DATAVACUUM FLOWSupplied with a vacuum gauge.Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 65–70Temperature range °C -10–80Weight g 1700–1800MaterialAl, PA, NBR, SS, TPEFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.22 4.86 15.0 6.0 4.5 2.7 1.7 1.4 0.78 0.21 — — 730.30 6.0 16.8 7.5 5.4 3.3 2.0 1.5 1.1 0.75 0.30 — 900.40 7.62 17.1 7.5 6.3 4.5 3.3 2.0 1.1 0.78 0.24 — 86EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.22 4.86 0.008 0.027 0.030 0.10 0.17 0.27 0.57 — — 730.30 6.0 0.007 0.020 0.040 0.083 0.15 0.23 0.33 0.53 1.3 900.40 7.62 0.007 0.018 0.037 0.060 0.097 0.20 0.30 0.57 — 86BLOW FLOWFeed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 20 40 60 70 80 90 100 110 120 130 140 kPa0.60 10.65 29 19.5 18.0 15.9 14.1 13.8 13.8 13.8 13.5 12.9 12.0 11.1 140200.40 MPa0.30 MPa0.22 MPa1.50.40 MPa0.30 MPa0.22 MPa300.60 MPa151.225s/l0.9Nl/s10Nl/s200.650.315001020304050607080900.010 20 30 40 50 60 70 80 90100 20 40 60 70 80 90 100 110 120 130 140-kPa-kPaVacuum flow Evacuation time Blow flow68 Specifications subject to change without notice.


VACUUM PUMPS P6010ORDERING INFORMATION1. Housing P6010 CodeHousingP60102. Vacuum Cartridge Module P6010 Codea Cartridge module Pi48-3X3 ALb Cartridge module Pi48-3X3, non-return valve AP3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 014. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plainLACover plate NPSF thread connections, Cover plate, plainLJ5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56ExampleOrdering numberP6010 Pi48-3X3, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AL 01 LA 52Vacuum pumpsP6010ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532Specifications subject to change without notice. 69


VACUUM PUMPS P6010P6010 PI48-3X4 COAX®patented technology Substationally lower air consumption ascompared to conventional ejectors Modular design Available with multiple connection alternatives Low noise level Low feed pressure that ensures highrealiability even in case of pressure drops Short evacuation timeTECHNICAL DATAVACUUM FLOWSupplied with a vacuum gauge.Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 65–70Temperature range °C -10–80Weight g 1700–1800MaterialAl, PA, NBR, SS, TPEFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.22 6.48 20.0 8.0 6.0 3.6 2.2 1.8 1.0 0.28 — — 730.30 8.0 22.4 10.0 7.2 4.4 2.6 2.0 1.4 1.0 0.40 — 900.40 10.16 22.8 10.0 8.4 6.0 4.4 2.6 1.4 1.0 0.32 — 86EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.22 6.48 0.006 0.020 0.023 0.075 0.13 0.20 0.43 — — 730.30 8.0 0.005 0.015 0.030 0.063 0.11 0.18 0.25 0.40 1.0 900.40 10.16 0.005 0.014 0.028 0.045 0.073 0.15 0.23 0.43 — 86BLOW FLOWFeed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 20 40 60 70 80 90 100 110 120 130 140 kPa0.60 14.2 38 26 24.0 21.2 18.8 18.4 18.4 18.4 18.0 17.2 16.0 14.8 140250.40 MPa0.30 MPa0.22 MPa1.00.40 MPa0.30 MPa0.22 MPa400.60 MPa200.83515s/l0.630Nl/sNl/s25100.42050.215001020304050607080900.010 20 30 40 50 60 70 80 90100 20 40 60 70 80 90 100 110 120 130 140-kPa-kPaVacuum flow Evacuation time Blow flow70 Specifications subject to change without notice.


VACUUM PUMPS P6010ORDERING INFORMATION1. Housing P6010 CodeHousingP60102. Vacuum Cartridge Module P6010 Codea Cartridge module Pi48-3X4 AMb Cartridge module Pi48-3X4, non-return valve AQ3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 014. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plainLACover plate NPSF thread connections, Cover plate, plainLJ5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56ExampleOrdering numberP6010 Pi48-3X4, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AM 01 LA 52Vacuum pumpsP6010ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532Specifications subject to change without notice. 71


VACUUM PUMPS P6010P6010 SI32-3X1 COAX®patented technology Substationally lower air consumption ascompared to conventional ejectors Modular design Available with multiple connection alternatives Low noise level High flow - suitable for handling of porous objectsand in case of leakage Short evacuation timeTECHNICAL DATAVACUUM FLOWSupplied with a vacuum gauge.Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 60–65Temperature range °C -10–80Weight g 1700–1800MaterialAl, PA, NBR, SS, TPEFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.40 1.25 5.0 2.9 1.9 1.2 0.80 0.40 0.10 — — — 600.50 1.5 5.7 3.3 2.2 1.4 0.85 0.60 0.35 0.18 — — 700.60 1.75 6.0 3.5 2.6 1.7 0.90 0.60 0.50 0.35 — — 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.40 1.25 0.030 0.070 0.14 0.24 0.42 1.0 — — — 600.50 1.5 0.020 0.060 0.11 0.21 0.35 0.60 1.0 — — 700.60 1.75 0.020 0.050 0.10 0.18 0.33 0.53 0.80 — — 75BLOW FLOWFeed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 10 20 30 40 50 60 70 80 kPa0.60 1.75 7.8 5.4 4.6 3.8 3.3 3.1 2.7 2.3 1.8 8060.60 MPa0.50 MPa0.40 MPa1.00.60 MPa0.50 MPa0.40 MPa80.60 MPa50.87Nl/s43s/l0.60.4Nl/s654210.232001020304050607080900.010 20 30 40 50 60 70 80 9010 10 20 30 40 50-kPa-kPaVacuum flow Evacuation time Blow flow60708072 Specifications subject to change without notice.


VACUUM PUMPS P6010ORDERING INFORMATION1. Housing P6010 CodeHousingP60102. Vacuum Cartridge Module P6010 Codea Cartridge module Si32-3X1 ABb Cartridge module Si32-3X1, non-return valve AF3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 014. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plainLACover plate NPSF thread connections, Cover plate, plainLJ5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x G3/4" 53Connections 2x G3/4", silencer 3/4" 54Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56Connections 2x 3/4" NPSF 57Connections 2x 3/4" NPSF, silencer 3/4" 58ExampleOrdering numberP6010 Si32-3X1, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AB 01 LA 52Vacuum pumpsP6010ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532Specifications subject to change without notice. 73


VACUUM PUMPS P6010P6010 SI32-3X2 COAX®patented technology Substationally lower air consumption ascompared to conventional ejectors Modular design Available with multiple connection alternatives Low noise level High flow - suitable for handling of porous objectsand in case of leakage Short evacuation timeTECHNICAL DATAVACUUM FLOWSupplied with a vacuum gauge.Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 60–65Temperature range °C -10–80Weight g 1700–1800MaterialAl, PA, NBR, SS, TPEFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.40 2.5 10.0 5.8 3.8 2.4 1.6 0.80 0.20 — — — 600.50 3.0 11.4 6.6 4.4 2.8 1.7 1.2 0.70 0.36 — — 700.60 3.5 12.0 7.0 5.2 3.4 1.8 1.2 1.0 0.70 — — 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.40 2.5 0.015 0.035 0.070 0.12 0.21 0.50 — — — 600.50 3.0 0.010 0.030 0.055 0.11 0.18 0.30 0.50 — — 700.60 3.5 0.010 0.025 0.050 0.090 0.17 0.27 0.40 — — 75BLOW FLOWFeed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 10 20 30 40 50 60 70 80 kPa0.60 3.5 15.5 10.8 9.2 7.6 6.6 6.2 5.4 4.6 3.6 80120.60 MPa0.50 MPa0.40 MPa0.50.60 MPa0.50 MPa0.40 MPa200.60 MPa100.4158s/l0.3Nl/s6Nl/s100.2420.15001020304050607080900.010 20 30 40 50 60 70 80 9000 10 20 30 40 50-kPa-kPaVacuum flow Evacuation time Blow flow60708074 Specifications subject to change without notice.


VACUUM PUMPS P6010ORDERING INFORMATION1. Housing P6010 CodeHousingP60102. Vacuum Cartridge Module P6010 Codea Cartridge module Si32-3X2 ACb Cartridge module Si32-3X2, non-return valve AG3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 014. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plainLACover plate NPSF thread connections, Cover plate, plainLJ5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x G3/4" 53Connections 2x G3/4", silencer 3/4" 54Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56Connections 2x 3/4" NPSF 57Connections 2x 3/4" NPSF, silencer 3/4" 58ExampleOrdering numberP6010 Si32-3X2, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AC 01 LA 52Vacuum pumpsP6010ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532Specifications subject to change without notice. 75


VACUUM PUMPS P6010P6010 SI32-3X3 COAX®patented technology Substationally lower air consumption ascompared to conventional ejectors Modular design Available with multiple connection alternatives Low noise level High flow - suitable for handling of porous objectsand in case of leakage Short evacuation timeTECHNICAL DATAVACUUM FLOWSupplied with a vacuum gauge.Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 60–65Temperature range °C -10–80Weight g 1700–1800MaterialAl, PA, NBR, SS, TPEFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.40 3.75 15.0 8.7 5.7 3.6 2.4 1.2 0.30 — — — 600.50 4.5 17.1 9.9 6.6 4.2 2.6 1.8 1.1 0.54 — — 700.60 5.25 18.0 10.5 7.8 5.1 2.7 1.8 1.5 1.1 — — 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.40 3.75 0.010 0.023 0.047 0.080 0.14 0.33 — — — 600.50 4.5 0.007 0.020 0.037 0.070 0.12 0.20 0.33 — — 700.60 5.25 0.007 0.017 0.033 0.060 0.11 0.18 0.27 — — 75BLOW FLOWFeed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 10 20 30 40 50 60 70 80 kPa0.60 5.25 23.3 16.2 13.8 11.4 9.9 9.3 8.1 6.9 5.4 80200.60 MPa0.50 MPa0.40 MPa0.350.60 MPa0.50 MPa0.40 MPa250.60 MPa0.30150.2520Nl/s10s/l0.200.15Nl/s1550.10100.05001020304050607080900.0010 20 30 40 50 60 70 80 90-kPa-kPaVacuum flow Evacuation time Blow flow50102030405060708076 Specifications subject to change without notice.


VACUUM PUMPS P6010ORDERING INFORMATION1. Housing P6010 CodeHousingP60102. Vacuum Cartridge Module P6010 Codea Cartridge module Si32-3X3 ADb Cartridge module Si32-3X3, non-return valve AH3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 014. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plainLACover plate NPSF thread connections, Cover plate, plainLJ5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56ExampleOrdering numberP6010 Si32-3X3, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AD 01 LA 52Vacuum pumpsP6010ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532Specifications subject to change without notice. 77


VACUUM PUMPS P6010P6010 SI32-3X4 COAX®patented technology Substationally lower air consumption ascompared to conventional ejectors Modular design Available with multiple connection alternatives Low noise level High flow - suitable for handling of porous objectsand in case of leakage Short evacuation timeTECHNICAL DATAVACUUM FLOWSupplied with a vacuum gauge.Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 60–65Temperature range °C -10–80Weight g 1700–1800MaterialAl, PA, NBR, SS, TPEFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.40 5.0 20.0 11.6 7.6 4.8 3.2 1.6 0.40 — — — 600.50 6.0 22.8 13.2 8.8 5.6 3.4 2.4 1.4 0.72 — — 700.60 7.0 24.0 14.0 10.4 6.8 3.6 2.4 2.0 1.4 — — 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.40 5.0 0.008 0.018 0.035 0.060 0.11 0.25 — — — 600.50 6.0 0.005 0.015 0.028 0.053 0.088 0.15 0.25 — — 700.60 7.0 0.005 0.013 0.025 0.045 0.083 0.13 0.20 — — 75BLOW FLOWFeed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 10 20 30 40 50 60 70 80 kPa0.60 7.0 31 21.6 18.4 15.2 13.2 12.4 10.8 9.2 7.2 80250.60 MPa0.50 MPa0.40 MPa0.250.60 MPa0.50 MPa0.40 MPa350.60 MPa200.203015s/l0.1525Nl/sNl/s20100.101550.0510001020304050607080900.0010 20 30 40 50 60 70 80 90-kPa-kPaVacuum flow Evacuation time Blow flow50102030405060708078 Specifications subject to change without notice.


VACUUM PUMPS P6010ORDERING INFORMATION1. Housing P6010 CodeHousingP60102. Vacuum Cartridge Module P6010 Codea Cartridge module Si32-3X4 AEb Cartridge module Si32-3X4, non-return valve AI3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 014. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plainLACover plate NPSF thread connections, Cover plate, plainLJ5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56ExampleOrdering numberP6010 Si32-3X4, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AE 01 LA 52Vacuum pumpsP6010ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532Specifications subject to change without notice. 79


VACUUM PUMPS P6010P6010 AVM COAX®multistage ejector with Pi48-3 or Si32-3vacuum cartridges Suitable for vacuum systems using numerouslarge suction cups Valves for ON/OFF of vacuum and for blow-off Adjustment valve for controlling the blow-off flow Two vacuum switches Automatic energy-saving function - can beswitched off in applications where leakage ispresent One single M12 8-pin electric connection thatfacilitates installation PNP or NPN with one and the same unitTECHNICAL DATASupplied with a vacuum gauge.Description Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 50–70MaterialAl, PA, NBR, SS, PMMA, ABS, TPETemperature range °C 0–50Weight g 2000–2100Voltage V 24 (22–30)Safety classificationIP65Current, max. output load mA 100Current consumption mA 110DisplayLED indicatorsTECHNICAL DATA, SPECIFICDescription Unit ValueLC, LL LD, LM LE, LN LF, LO LG, LP LH, LQFunction, on/off NO NO NO NC NC NCSignal range -kPa 30/50 30/70 50/70 30/50 30/70 50/70PERFORMANCE TABLESDepending upon choice of COAX®Cartridge, applicable performance data of the P6010 AVM can be found inthe tables for vacuum flow and evacuation time for models P6010 Pi48-3x1 to x4 as well as for Si32-3x1 to x4.ORDERING INFORMATION1. Housing P6010 CodeHousingP60102. Vacuum Cartridge Modules P6010 CodeCartridge module Pi48-3X1, non-return valveANCartridge module Pi48-3X2, non-return valveAOCartridge module Pi48-3X3, non-return valveAPCartridge module Pi48-3X4, non-return valveAQCartridge module Si32-3X1, non-return valveAFCartridge module Si32-3X2, non-return valveAGCartridge module Si32-3X3, non-return valveAHCartridge module Si32-3X4, non-return valveAI3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 0180 Specifications subject to change without notice.


VACUUM PUMPS P60104. Cover plates P6010 CodeFunction AVM NO 30/50, Cover plate G thread connectionsLCFunction AVM NO 30/70, Cover plate G thread connectionsLDFunction AVM NO 50/70, Cover plate G thread connectionsLEFunction AVM NC 30/50, Cover plate G thread connectionsLFFunction AVM NC 30/70, Cover plate G thread connectionsLGFunction AVM NC 50/70, Cover plate G thread connectionsLHFunction AVM NO 30/50, Cover plate NPSF thread connectionsLLFunction AVM NO 30/70, Cover plate NPSF thread connectionsLMFunction AVM NO 50/70, Cover plate NPSF thread connectionsLNFunction AVM NC 30/50, Cover plate NPSF thread connectionsLOFunction AVM NC 30/70, Cover plate NPSF thread connectionsLPFunction AVM NC 50/70, Cover plate NPSF thread connectionsLQNO = Normally open valve for vacuum on/off, NC = Normally closed valve for vacuum on/off5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56ExampleP6010 Si32-3X2, Mounting T-slot, Cover plate with AVM NO 30/50 function and G-threads, Connections 2x G1"and silencer 1"Ordering numberP6010 AG 01 LC 52Vacuum pumpsP6010ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 1 MPa 0112532Cable 2m 0.25 x 7 PUR with electrical connector M12 8-pin 0110238Specifications subject to change without notice. 81


VACUUM PUMPS P6010P6010 PCC COAX®multistage ejector with Pi48-3 or Si32-3vacuum cartridges Programmable for constant vacuum level or blowpressurelevel in the system Quick adjustment Easy to install in control systems Low power consumption, 24 VDC/120 mA Integrated analogue vacuum or blow-pressureswitchSupplied with a vacuum gauge.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 1.0Noise level dBA 50–70Temperature range °C 3–50Weight g 2100–2200MaterialAl, PA, NBR, SS, AiSi302Voltage supply V 24 (21.8–26.4)Voltage signal, input/output V 0–10Scale factor signal out, vacuum -kPa 0–100Scale factor signal in, vacuum -kPa 0–90Scale factor signal out, blow MPa 0–0.2Safety classificationIP65Current consumption mA


VACUUM PUMPS P60105. Connections for vacuum and exhaust P6010 CodeConnections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56ExampleP6010 Si32-3X2, Mounting T-slot, Cover plate with PCC vacuum function and G-threads, Connections 2x G1"and silencer 1"Ordering numberP6010 AC 01 LB 52Vacuum pumpsP6010ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Cable L=3m, M16 8-pin, angled 0112395Cable, L=3m, M16 8-pin, straight 0112393Manometer 1 MPa 0112532Specifications subject to change without notice. 83


VACUUM PUMPS P6010P6010 CLASSIC COAX®multistage ejector with Pi48-3 or Si32-3vacuum cartridges Connections can be made on the long side of theejector Retro-compatible with PIAB’s Classic model inregard to mountingSupplied with a vacuum gauge.TECHNICAL DATADescription Unit ValueFeed pressure, max MPa 0.7Noise level dBA 50–65Temperature range °C -10–80Weight g 1700–1800MaterialAl, PA, NBR, SS, TPEPERFORMANCE TABLESDepending upon choice of COAX® Cartridge, performance data of the P6010 Classic can be found in the tablesfor vacuum flow, evacuation time and blow flow for models P6010 Pi48-3x1 to x4 as well as for Si32-3x1 to x4.84 Specifications subject to change without notice.


VACUUM PUMPS P6010ORDERING INFORMATION1. Housing P6010 CodeHousingP60102. Vacuum Cartridge Modules P6010 Codea Cartridge module Pi48-3X1 AJa Cartridge module Pi48-3X2 AKa Cartridge module Pi48-3X3 ALa Cartridge module Pi48-3X4 AMb Cartridge module Pi48-3X1, non-return valve ANb Cartridge module Pi48-3X2, non-return valve AOb Cartridge module Pi48-3X3, non-return valve APb Cartridge module Pi48-3X4, non-return valve AQa Cartridge module Si32-3X1 ABa Cartridge module Si32-3X2 ACa Cartridge module Si32-3X3 ADa Cartridge module Si32-3X4 AEb Cartridge module Si32-3X1, non-return valve AFb Cartridge module Si32-3X2, non-return valve AGb Cartridge module Si32-3X3, non-return valve AHb Cartridge module Si32-3X4, non-return valve AI3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 014. Cover plates P6010 CodeCover plate Classic G thread connections, Cover plate plainLICover plate Classic NPSF thread connections, Cover plate plainLK5. Connections for vacuum and exhaust P6010 CodeConnections 2x G3/4" 53Connections 2x G3/4", silencer 3/4" 54Connections 2x 3/4" NPSF 57Connections 2x 3/4" NPSF, silencer 3/4" 58ExampleOrdering numberP6010 Pi48-3X4, Mounting T-slot, Cover plate Classic G-threads, Connections 2x G3/4" and silencer 3/4" P6010 AM 01 LI 54Vacuum pumpsP6010ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Manometer 250 kPa 0112533Manometer 1 Mpa 0112532Specifications subject to change without notice. 85


VACUUM PUMPS MINIL7 Large vacuum flows Small size and low weight Good for handling porous materials or if leakageis presentSupplied with compressed-air hose connector.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 57–68Temperature range ºC -20–80Weight g 30MaterialPA, POM, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 0.49 0.72 0.49 0.29 0.25 0.20 0.16 0.10 0.067 – – 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 0.49 0.093 0.31 0.72 1.2 1.8 2.6 3.8 – – 750.80.6 MPa4.00.6 MPa0.73.50.63.00.52.5Nl/s0.4s/l2.00.31.50.21.00.10.50.0010 20 30 40-kPaVacuum flow5060700.01020 30 40 50-kPaEvacuation time607086 Specifications subject to change without notice.


VACUUM PUMPS MINIORDERING INFORMATIONDescriptionArt. No.Vacuum pump MINI L7, conn. A, NBR sealings 0102853Vacuum pump MINI L7, conn. A, NBR sealings, non-return valve 01028541 31 3223NPSF 1(8"26121.517.52x 3.2M524301116.55Vacuum pumpsMINIORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MINI 5–28, NBR sealings 3201097Sealing kit MINI 5–28, Viton® sealings3201097VSealing kit MINI 5–28, EPDM sealings3201097EKits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 87


VACUUM PUMPS MINIL14 Large vacuum flows Small size and low weight Good for handling porous materials or if leakageis presentSupplied with push-in hose connector forcompressed air (for pumps with connection plate B).Supplied with push-in hose connector forcompressed air and external through-flow silencer(for pumps with connection plate C).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 57–68Temperature range ºC -20–80Weight g 35–60MaterialAl, ABS, PA, POM, SS, NBRVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 0.98 1.5 1.0 0.57 0.45 0.39 0.32 0.24 0.13 – – 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 0.98 0.064 0.17 0.36 0.59 0.88 1.3 1.8 – – 751.50.6 MPa2.00.6 MPa1.21.5Nl/s0.90.6s/l1.00.30.50.001020 30 40-kPaVacuum flow5060700.01020 30 40 50-kPaEvacuation time607088 Specifications subject to change without notice.


VACUUM PUMPS MINIORDERING INFORMATIONDescriptionArt. No.A Vacuum pump MINI L14, conn. B1, NBR sealings 0102831A Vacuum pump MINI L14, conn. B1, NBR sealings, non-return valve 0102832B Vacuum pump MINI L14, conn. B, NBR sealings 0103055B Vacuum pump MINI L14, conn. B, NBR sealings, non-return valve 0103056C Vacuum pump MINI L14, conn. C, NBR sealings 0102743C Vacuum pump MINI L14, conn. C, NBR sealings, non-return valve 01027443 1 31 31 32277.334.32648"NP ,G24.20.225252564NPSF 3/8"2x 3.224.520.5242x3.22024Vacuum pumpsMINI8"NP ,G24 15NPSF 1/8"241712.5A530B20.5CORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MINI 5–28, NBR sealings 3201097Sealing kit MINI 5–28, Viton® sealings3201097VSealing kit MINI 5–28, EPDM sealings3201097EKits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 89


VACUUM PUMPS MINIL28 Large vacuum flows Small size and low weight Good for handling porous materials or if leakageis presentSupplied with push-in hose connector forcompressed air (for pumps with connection plate B).Supplied with push-in hose connector forcompressed air and external through-flow silencer(for pumps with connection plate C).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 57–68Temperature range ºC -20–80Weight g 60–74MaterialAl, ABS, PA, POM, SS, NBRVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 2.0 2.6 1.7 1.1 0.89 0.74 0.55 0.36 0.17 – – 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 2.0 0.047 0.11 0.20 0.32 0.46 0.69 1.1 – – 753.00.6 MPa1.20.6 MPa2.51.02.00.8Nl/s1.5s/l0.61.00.40.50.20.001020 30 40-kPaVacuum flow5060700.01020 30 40 50-kPaEvacuation time607090 Specifications subject to change without notice.


VACUUM PUMPS MINIORDERING INFORMATIONDescriptionArt. No.A Vacuum pump MINI L28, conn. B1, NBR sealings 0102833A Vacuum pump MINI L28, conn. B1, NBR sealings, non-return valve 0102834B Vacuum pump MINI L28, conn. B, NBR sealings 0103061B Vacuum pump MINI L28, conn. B, NBR sealings, non-return valve 0103062C Vacuum pump MINI L28, conn. C, NBR sealings 0102749C Vacuum pump MINI L28, conn. C, NBR sealings, non-return valve 01027501227.4.3/ N ,G2x 3.5525Vacuum pumpsMINI1/ N ,G2417.12A30BCORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MINI 5–28, NBR sealings 3201097Sealing kit MINI 5–28, Viton® sealings3201097VSealing kit MINI 5–28, EPDM sealings3201097EKits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 91


VACUUM PUMPS MINIL56 Large vacuum flows Small size and low weight Good for handling porous materials or if leakageis presentSupplied with two through-flow silencers.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 57–68Temperature range ºC -20–80Weight g 420MaterialAl, PA, POM, ABS, SS, NBRVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 4.0 5.1 3.5 2.0 1.7 1.4 1.1 0.81 0.43 – – 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 4.0 0.023 0.053 0.10 0.16 0.23 0.33 0.50 – – 7560.6 MPa0.50.6 MPa50.440.3Nl/s321s/l0.20.1001020 30 40 50-kPaVacuum flow60700.01020 30 40 50-kPaEvacuation time607092 Specifications subject to change without notice.


VACUUM PUMPS MINIORDERING INFORMATIONDescriptionArt. No.Vacuum pump MINI L56, conn. K, NBR sealings 0102797Vacuum pump MINI L56, conn. K, NBR sealings, non-return valve 0102798Vacuum pumpsMINIORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MINI 30–60, NBR sealings 0100491Sealing kit MINI 30–60, Viton® sealings0100491VSealing kit MINI 30–60, EPDM sealings0100491EKits include flap valves, gaskets and compressed air filters.Specifications subject to change without notice. 93


VACUUM PUMPS MINIM5L Medium vacuum levels to 90 -kPa Small size and low weight Operates at only 0.38 MPaSupplied with compressed-air hose connector.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 57–68Temperature range ºC -20–80Weight g 30MaterialPA, POM, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 0.55 0.73 0.50 0.26 0.14 0.12 0.10 0.080 0.050 0.020 – 840.38 0.38 0.58 0.30 0.22 0.18 0.14 0.10 0.080 0.040 0.010 – 81EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 0.55 0.13 0.36 1.0 1.8 2.8 4.0 5.7 9.4 – 840.38 0.38 0.20 0.61 1.2 1.8 2.6 3.8 5.9 11.1 – 810.80.6 MPa0.38 MPa120.6 MPa0.38 MPaNl/s0.70.60.50.4s/l10860.340.20.120.001020 30 40 50-kPaVacuum flow60708001020 30 40 50 60-kPaEvacuation time708094 Specifications subject to change without notice.


VACUUM PUMPS MINIORDERING INFORMATIONDescriptionArt. No.Vacuum pump MINI M5L, conn. A, NBR sealings 0102865Vacuum pump MINI M5L, conn. A, NBR sealings, non-return valve 01028661 31 3223NPSF 1(8"26121.517.52x 3.2M524301116.55Vacuum pumpsMINIORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MINI 5–28, NBR sealings 3201097Sealing kit MINI 5–28, Viton® sealings3201097VSealing kit MINI 5–28, EPDM sealings3201097EKits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 95


VACUUM PUMPS MINIM10L Medium vacuum levels to 90 -kPa Small size and low weight Operates at only 0.38 MPaSupplied with compressed-air hose connector.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 57–68Temperature range ºC -20–80Weight g 30MaterialPA, POM, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 1.1 1.3 0.91 0.48 0.29 0.26 0.21 0.13 0.090 0.030 – 840.38 0.76 1.1 0.57 0.39 0.35 0.30 0.21 0.12 0.060 0.020 – 81EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 1.1 0.079 0.20 0.50 0.92 1.4 2.1 3.0 5.0 – 840.38 0.76 0.13 0.31 0.57 0.90 1.3 2.0 3.2 7.1 – 811.50.6 MPa0.38 MPa80.6 MPa0.38 MPa1.2760.95Nl/ss/l40.630.3210.001020 30 40 50-kPaVacuum flow60708001020 30 40 50 60-kPaEvacuation time708096 Specifications subject to change without notice.


VACUUM PUMPS MINIORDERING INFORMATIONDescriptionArt. No.Vacuum pump MINI M10L, conn. A, NBR sealings 0102871Vacuum pump MINI M10L, conn. A, NBR sealings, non-return valve 01028721 31 3223NPSF 1(8"26121.517.52x 3.2M524301116.55Vacuum pumpsMINIORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MINI 5–28, NBR sealings 3201097Sealing kit MINI 5–28, Viton® sealings3201097VSealing kit MINI 5–28, EPDM sealings3201097EKits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 97


VACUUM PUMPS MINIM20L Medium vacuum levels to 90 -kPa Small size and low weight Operates at only 0.38 MPaSupplied with push-in hose connector forcompressed air (for pumps with connection plate B).Supplied with push-in hose connector forcompressed air and external through-flow silencer(for pumps with connection plate C).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 57–68Temperature range ºC -20–80Weight g 60–74MaterialAl, ABS, PA, POM, SS, NBRVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 2.2 2.4 1.7 0.95 0.57 0.48 0.38 0.29 0.19 0.060 – 840.38 1.5 2.0 1.2 0.76 0.67 0.53 0.41 0.33 0.19 0.020 – 81EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 2.2 0.038 0.10 0.24 0.43 0.68 1.0 1.5 2.5 – 840.38 1.5 0.052 0.14 0.26 0.42 0.64 1.0 1.7 3.7 – 812.50.6 MPa0.38 MPa4.00.6 MPa0.38 MPa2.03.53.01.5s/l2.5Nl/s2.01.01.50.51.00.50.001020 30 40 50-kPaVacuum flow6070800.01020 30 40 50 60-kPaEvacuation time708098 Specifications subject to change without notice.


VACUUM PUMPS MINIORDERING INFORMATIONDescriptionArt. No.A Vacuum pump MINI M20L, conn. B1, NBR sealings 0102839A Vacuum pump MINI M20L, conn. B1, NBR sealings, non-return valve 0102840B Vacuum pump MINI M20L, conn. B, NBR sealings 0103079B Vacuum pump MINI M20L, conn. B, NBR sealings, non-return valve 0103080C Vacuum pump MINI M20L, conn. C, NBR sealings 0102767C Vacuum pump MINI M20L, conn. C, NBR sealings, non-return valve 01027681227.4.3/ N ,G2x 3.5525Vacuum pumpsMINI1/ N ,G2417.12A30BCORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MINI 5–28, NBR sealings 3201097Sealing kit MINI 5–28, Viton® sealings3201097VSealing kit MINI 5–28, EPDM sealings3201097EKits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 99


VACUUM PUMPS MINIM40L Medium vacuum levels to 90 -kPa Small size and low weight Operates at only 0.38 MPaSupplied with two through-flow silencers.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 57–68Temperature range ºC -20–80Weight g 420MaterialAl, PA, POM, NBR, ABS, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 4.4 4.8 3.1 1.7 1.1 0.93 0.74 0.57 0.36 0.11 – 840.38 3.0 4.0 2.2 1.4 1.2 1.0 0.71 0.43 0.19 0.050 – 81EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 4.4 0.031 0.064 0.13 0.22 0.34 0.50 0.70 1.3 – 840.38 3.0 0.030 0.074 0.13 0.21 0.32 0.50 0.95 1.6 – 8150.6 MPa0.38 MPa2.00.6 MPa0.38 MPa41.5Nl/s32s/l1.010.5001020 30 40 50-kPaVacuum flow6070800.01020 30 40 50 60-kPaEvacuation time7080100 Specifications subject to change without notice.


VACUUM PUMPS MINIORDERING INFORMATIONDescriptionArt. No.Vacuum pump MINI M40L, conn. K, NBR sealings 0102805Vacuum pump MINI M40L, conn. K, NBR sealings, non-return valve 0102806Vacuum pumpsMINIORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MINI 30–60, NBR sealings 0100491Sealing kit MINI 30–60, Viton® sealings0100491VSealing kit MINI 30–60, EPDM sealings0100491EKits include flap valves, gaskets and compressed air filters.Specifications subject to change without notice. 101


VACUUM PUMPS MINIX5L Extra vacuum level to 93 -kPa Small size and low weight Use in tightly sealed or non-porous applicationsSupplied with compressed-air hose connector.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 62–66Temperature range ºC -20–80Weight g 30MaterialPA, POM, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.40 0.39 0.48 0.24 0.12 0.11 0.10 0.086 0.071 0.057 0.030 0.006 93EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.40 0.39 0.17 0.82 1.7 2.7 3.9 5.4 7.4 10.6 22.5 930.50.4 MPa250.4 MPa0.4200.3s/l15s/l0.2100.150.001020 30 40 50 60-kPaVacuum flow70809001020 30 40 50 60 70-kPaEvacuation time8090102 Specifications subject to change without notice.


VACUUM PUMPS MINIORDERING INFORMATIONDescriptionArt. No.Vacuum pump MINI X5L, conn. A, NBR sealings 3222127Vacuum pump MINI X5L, conn. A, NBR sealings, non-return valve3222127A1 31 3223NPSF 1(8"26121.517.52x 3.2M524301116.55Vacuum pumpsMINIORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MINI 5–28, NBR sealings 3201097Sealing kit MINI 5–28, Viton® sealings3201097VSealing kit MINI 5–28, EPDM sealings3201097EKits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 103


VACUUM PUMPS MINIX10L Extra vacuum level to 93 -kPa Small size and low weight Use in tightly sealed or non-porous applicationsSupplied with compressed-air hose connector.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 62–66Temperature range ºC -20–80Weight g 30MaterialPA, POM, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.40 0.79 0.76 0.35 0.24 0.21 0.16 0.13 0.10 0.070 0.040 0.010 93EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.40 0.79 0.11 0.47 0.94 1.5 2.2 3.1 4.3 6.6 14.0 930.80.4 MPa150.4 MPa0.70.6120.59Nl/s0.4s/l0.360.230.10.001020 30 40 50 60-kPaVacuum flow70809001020 30 40 50 60 70-kPaEvacuation time8090104 Specifications subject to change without notice.


VACUUM PUMPS MINIORDERING INFORMATIONDescriptionArt. No.Vacuum pump MINI X10L, conn. A, NBR sealings 3222157Vacuum pump MINI X10L, conn. A, NBR sealings, non-return valve3222157A1 31 3223NPSF 1(8"26121.517.52x 3.2M524301116.55Vacuum pumpsMINIORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MINI 5–28, NBR sealings 3201097Sealing kit MINI 5–28, Viton® sealings3201097VSealing kit MINI 5–28, EPDM sealings3201097EKits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 105


VACUUM PUMPS MINIX20L Extra vacuum level to 93 -kPa Small size and low weight Use in tightly sealed or non-porous applicationsSupplied with push-in hose connector forcompressed air (for pumps with connection plate B).Supplied with push-in hose connector forcompressed air and external through-flow silencer(for pumps with connection plate C).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 62–66Temperature range ºC -20–80Weight g 60–74MaterialAl, ABS, PA, POM, SS, NBRVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.40 1.6 1.9 1.0 0.50 0.44 0.38 0.30 0.25 0.17 0.10 0.020 93EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.40 1.6 0.055 0.20 0.40 0.65 0.97 1.4 1.9 2.7 5.1 932.00.4 MPa60.4 MPa51.54s/lNl/s1.0320.510.001020 30 40 50 60-kPaVacuum flow70809001020 30 40 50 60 70-kPaEvacuation time8090106 Specifications subject to change without notice.


VACUUM PUMPS MINIORDERING INFORMATIONDescriptionArt. No.A Vacuum pump MINI X20L, conn. B1, NBR sealings 0103203A Vacuum pump MINI X20L, conn. B1, NBR sealings, non-return valve 0103204B Vacuum pump MINI X20L, conn. B, NBR sealings 3222278B Vacuum pump MINI X20L, conn. B, NBR sealings, non-return valve 3222278AC Vacuum pump MINI X20L, conn. C, NBR sealings 3222279C Vacuum pump MINI X20L, conn. C, NBR sealings, non-return valve 3222279A1227.4.3/ N ,G2x 3.5525Vacuum pumpsMINI1/ N ,G2417.12A30BCORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MINI 5–28, NBR sealings 3201097Sealing kit MINI 5–28, Viton® sealings3201097VSealing kit MINI 5–28, EPDM sealings3201097EKits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 107


VACUUM PUMPS MINIX40L Extra vacuum level to 93 -kPa Small size and low weight Use in tightly sealed or non-porous applicationsSupplied with two through-flow silencers.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 60–70Temperature range ºC -20–80Weight g 420MaterialAl, PA, POM, NBR, SS, ABSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.40 3.1 3.2 1.5 1.0 0.90 0.70 0.60 0.50 0.40 0.17 0.038 93EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.40 3.1 0.038 0.12 0.22 0.33 0.48 0.68 1.2 2.2 3.2 933.50.4 MPa3.50.4 MPa3.03.02.52.5Nl/s2.01.51.0s/l2.01.51.00.50.50.001020 30 40 50 60-kPaVacuum flow7080900.01020 30 40 50 60 70-kPaEvacuation time8090108 Specifications subject to change without notice.


VACUUM PUMPS MINIORDERING INFORMATIONDescriptionArt. No.Vacuum pump MINI X40L, conn. K, NBR sealings 0100423Vacuum pump MINI X40L, conn. K, NBR sealings, non-return valve 0100425Vacuum pumpsMINIORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MINI 30–60, NBR sealings 0100491Sealing kit MINI 30–60, Viton® sealings0100491VSealing kit MINI 30–60, EPDM sealings0100491EKits include flap valves, gaskets and compressed air filters.Specifications subject to change without notice. 109


VACUUM PUMPS CLASSICL25 Large vacuum flows Short evacuation time Good for handling porous materials or if leakageis present Energy-Saving (ES) available Available with connection plate in aluminium (AD)and composite PPS (D).Supplied with a push-in connector for compressedair, through-flow silencer and mounting brackets(see Accessories).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 60–65Temperature range ºC -20–80Weight g 575–760MaterialAl, PPS, SS, PA, NBRVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 -kPa0.60 1.8 6.1 3.3 2.2 1.4 0.81 0.64 0.45 0.29 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 -kPa0.60 1.8 0.042 0.074 0.12 0.21 0.36 0.56 0.88 7580.6 MPa1.00.6 MPa760.8Nl/s54321s/l0.60.40.2001020 30 40 50-kPaVacuum flow60700.01020 30 40 50-kPaEvacuation time6070110 Specifications subject to change without notice.


VACUUM PUMPS CLASSICORDERING INFORMATIONDescriptionArt. No.B Vacuum pump CLASSIC L25, conn. AD, NBR sealings 0102117C Vacuum pump CLASSIC L25, conn. AD, NBR sealings, non-return valve 0102118B Vacuum pump CLASSIC L25, conn. D, NBR sealings 0102025C Vacuum pump CLASSIC L25, conn. D, NBR sealings, non-return valve 0102026B Vacuum pump CLASSIC L25, conn. D, Viton® sealings 0102212C Vacuum pump CLASSIC L25, conn. D, Viton® sealings, non-return valve 0102213A Vacuum pump CLASSIC L25, conn. AD, NBR sealings, ES 0103095Vacuum pumpsCLASSICORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC, NBR sealings 3201069Sealing kit CLASSIC, Viton® sealings3201069VSealing kit CLASSIC, EPDM sealings3201069EES-kit CLASSIC, G1/8"-G1/4" 0103109Sealing kits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 111


VACUUM PUMPS CLASSICL50 Large vacuum flows Short evacuation time Good for handling porous materials or if leakageis present Energy-Saving (ES) available Available with connection plate in aluminium (AD)and composite PPS (D).Supplied with a push-in connector for compressedair, through-flow silencer and mounting brackets(see Accessories).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 60–65Temperature range ºC -20–80Weight g 575–760MaterialAl, PPS, SS, PA, NBRVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 -kPa0.60 3.5 10.9 5.7 3.8 2.5 1.4 1.1 0.80 0.48 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 -kPa0.60 3.5 0.015 0.033 0.060 0.11 0.19 0.29 0.45 75120.6 MPa0.50.6 MPa100.4Nl/s864s/l0.30.220.1001020 30 40 50-kPaVacuum flow60700.01020 30 40 50-kPaEvacuation time6070112 Specifications subject to change without notice.


VACUUM PUMPS CLASSICORDERING INFORMATIONDescriptionArt. No.B Vacuum pump CLASSIC L50, conn. AD, NBR sealings 0102119C Vacuum pump CLASSIC L50, conn. AD, NBR sealings, non-return valve 0102120B Vacuum pump CLASSIC L50, conn. D, NBR sealings 0102027C Vacuum pump CLASSIC L50, conn. D, NBR sealings, non-return valve 0102028B Vacuum pump CLASSIC L50, conn. D, Viton® sealings 0102216C Vacuum pump CLASSIC L50, conn. D, Viton® sealings, non-return valve 0102217A Vacuum pump CLASSIC L50, conn. AD, NBR sealings, ES 0103097Vacuum pumpsCLASSICORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC, NBR sealings 3201069Sealing kit CLASSIC, Viton® sealings3201069VSealing kit CLASSIC, EPDM sealings3201069EES-kit CLASSIC, G1/8"-G1/4" 0103109Sealing kits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 113


VACUUM PUMPS CLASSICL100 Large vacuum flows Short evacuation time Good for handling porous materials or if leakageis present Energy-Saving (ES) available Available with connection plate in aluminium (AD)and composite PPS (D).Supplied with a push-in connector for compressedair, through-flow silencer and mounting brackets(see Accessories).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 60–65Temperature range ºC -20–80Weight g 800–1065MaterialAl, PPS, SS, PA, NBRVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 -kPa0.60 7.0 16.5 9.6 7.5 5.0 2.9 2.3 1.6 0.95 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 -kPa0.60 7.0 0.008 0.018 0.033 0.060 0.10 0.15 0.23 75200.6 MPa0.250.6 MPa150.20Nl/s105s/l0.150.100.05001020 30 40-kPaVacuum flow5060700.001020 30 40 50-kPaEvacuation time6070114 Specifications subject to change without notice.


VACUUM PUMPS CLASSICORDERING INFORMATIONDescriptionArt. No.B Vacuum pump CLASSIC L100, conn. AD, NBR sealings 0102121C Vacuum pump CLASSIC L100, conn. AD, NBR sealings, non-return valve 0102122B Vacuum pump CLASSIC L100, conn. D, NBR sealings 0102029C Vacuum pump CLASSIC L100, conn. D, NBR sealings, non-return valve 0102030B Vacuum pump CLASSIC L100, conn. D, Viton® sealings 0102220C Vacuum pump CLASSIC L100, conn. D, Viton® sealings, non-return valve 0102221A Vacuum pump CLASSIC L100, conn. AD, non-return valve, ES 0103099Vacuum pumpsCLASSICORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC, NBR sealings 3201069Sealing kit CLASSIC, Viton® sealings3201069VSealing kit CLASSIC, EPDM sealings3201069EES-kit CLASSIC, G1/8"-G1/4" 0103109Sealing kits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 115


VACUUM PUMPS CLASSICM25L Medium vacuum levels to 90 -kPa Operates at only 0.34 MPa Good for handling porous materials or if leakageis present Energy-Saving (ES) available Available with connection plate in aluminium (AD)and composite PPS (D).Supplied with a push-in connector for compressedair, through-flow silencer and mounting brackets(see Accessories).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 60–65Temperature range ºC -20–80Weight g 575–760MaterialAl, PPS, SS, PA, NBRVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 3.0 6.7 4.1 1.9 1.5 1.4 1.1 0.70 0.30 0.10 890.34 1.9 5.9 2.7 1.8 1.2 0.75 0.51 0.38 0.28 0.11 0.020 91EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 3.0 0.019 0.048 0.097 0.16 0.24 0.35 0.58 1.5 890.34 1.9 0.023 0.058 0.12 0.23 0.40 0.64 0.99 1.6 3.9 9180.6 MPa0.34 MPa4.00.6 MPa0.34 MPa73.563.052.5Nl/s4s/l2.031.521.010.5001020 30 40 50 60-kPaVacuum flow7080900.01020 30 40 50 60-kPaEvacuation time708090116 Specifications subject to change without notice.


VACUUM PUMPS CLASSICORDERING INFORMATIONDescriptionArt. No.B Vacuum pump CLASSIC M25L, conn. AD, NBR sealings 0102133C Vacuum pump CLASSIC M25L, conn. AD, NBR sealings, non-return valve 0102134B Vacuum pump CLASSIC M25L, conn. D, NBR sealings 0102031B Vacuum pump CLASSIC M25L, conn. D, Viton® sealings 0102236A Vacuum pump CLASSIC M25L, conn. AD, NBR sealings, ES 0103090Vacuum pumpsCLASSICORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC, NBR sealings 3201069Sealing kit CLASSIC, Viton® sealings3201069VSealing kit CLASSIC, EPDM sealings3201069EES-kit CLASSIC, G1/8"-G1/4" 0103109Sealing kits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 117


VACUUM PUMPS CLASSICM50L Medium vacuum levels to 90 -kPa Operates at only 0.34 MPa Good for handling porous materials or if leakageis present Energy-Saving (ES) available Available with connection plate in aluminium (AD)and composite PPS (D).Supplied with a push-in connector for compressedair, through-flow silencer and mounting brackets(see Accessories).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 60–65Temperature range ºC -20–80Weight g 575–760MaterialAl, PPS, SS, PA, NBRVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 6.0 11.4 7.3 3.6 3.2 2.7 2.0 1.24 0.38 0.10 890.34 3.7 10.3 4.9 3.5 2.2 1.3 1.0 0.80 0.50 0.19 0.010 91EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 6.0 0.011 0.026 0.051 0.080 0.12 0.19 0.33 0.82 890.34 3.7 0.014 0.033 0.062 0.12 0.21 0.33 0.50 0.82 2.5 91120.6 MPa0.34 MPa2.50.6 MPa0.34 MPa102.0Nl/s8642s/l1.51.00.5001020 30 40 50 60-kPaVacuum flow7080900.01020 30 40 50 60-kPaEvacuation time708090118 Specifications subject to change without notice.


VACUUM PUMPS CLASSICORDERING INFORMATIONDescriptionArt. No.B Vacuum pump CLASSIC M50L, conn. AD, NBR sealings 0102135C Vacuum pump CLASSIC M50L, conn. AD, NBR sealings, non-return valve 0102136B Vacuum pump CLASSIC M50L, conn. D, NBR sealings 0102033B Vacuum pump CLASSIC M50L, conn. D, Viton® sealings 0102240A Vacuum pump CLASSIC M50L, conn. AD, NBR sealings, ES 0103092Vacuum pumpsCLASSICORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC, NBR sealings 3201069Sealing kit CLASSIC, Viton® sealings3201069VSealing kit CLASSIC, EPDM sealings3201069EES-kit CLASSIC, G1/8"-G1/4" 0103109Sealing kits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 119


VACUUM PUMPS CLASSICM100L Medium vacuum levels to 90 -kPa Operates at only 0.34 MPa Good for handling porous materials or if leakageis present Energy-Saving (ES) available Available with connection plate in aluminium (AD)and composite PPS (D).Supplied with a push-in connector for compressedair, through-flow silencer and mounting brackets(see Accessories).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 60–65Temperature range ºC -20–80Weight g 800–900MaterialAl, PPS, SS, NBRVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 12.0 15.5 9.6 7.2 6.3 5.1 3.8 2.1 0.67 0.29 890.34 7.5 13.6 8.2 5.8 3.5 2.4 1.9 1.4 1.0 0.48 0.010 91EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 12.0 0.011 0.022 0.035 0.050 0.070 0.11 0.20 0.49 890.34 7.5 0.015 0.027 0.045 0.080 0.12 0.18 0.26 0.43 1.2 91200.6 MPa0.34 MPa1.20.6 MPa0.34 MPa1.0150.8Nl/s10s/l0.60.450.2001020 30 40 50 60-kPaVacuum flow7080900.01020 30 40 50 60-kPaEvacuation time708090120 Specifications subject to change without notice.


VACUUM PUMPS CLASSICORDERING INFORMATIONDescriptionArt. No.A Vacuum pump CLASSIC M100L, conn. AD, NBR sealings 0102137B Vacuum pump CLASSIC M100L, conn. AD, NBR sealings, non-return valve 0102138A Vacuum pump CLASSIC M100L, conn. D, NBR sealings 0102035A Vacuum pump CLASSIC M100L, conn. D, Viton® sealings 0106736Vacuum pumpsCLASSICORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC, NBR sealings 3201069Sealing kit CLASSIC, Viton® sealings3201069VSealing kit CLASSIC, EPDM sealings3201069EES-kit CLASSIC, G1/8"-G1/4" 0103109Sealing kits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 121


VACUUM PUMPS CLASSICH40 Higher vacuum levels to 99.8 -kPa Use with practically zero leakage present andnon-porous applications Available with connection plate in aluminium (AD)and composite PPS (D)Supplied with a push-in connector for compressedair, through-flow silencer and mounting brackets(see Accessories).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 60–65Temperature range ºC -20–80Weight g 530–620MaterialAl, PPS, SS, NBRVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 95 99 -kPa0.60 2.6 2.8 2.1 1.5 0.90 0.40 0.30 0.20 0.14 0.10 0.095 0.019 0.005 99.8EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 95 99 99.5 -kPa0.60 2.6 0.032 0.075 0.15 0.32 0.64 1.1 1.7 2.6 3.9 5.5 9.8 12.0 99.83.00.6 MPa120.6 MPa2.5102.08Nl/s1.5s/l61.040.520.0010 20 30 40 50 60 70 80 90 95 99-kPaVacuum flow010 20 30 40 50 60 70 80 90 95 99 99.5-kPaEvacuation time122 Specifications subject to change without notice.


VACUUM PUMPS CLASSICORDERING INFORMATIONDescriptionArt. No.A Vacuum pump CLASSIC H40, conn. AD, NBR sealings 0102129B Vacuum pump CLASSIC H40, conn. AD, NBR sealings, non-return valve 0102130A Vacuum pump CLASSIC H40, conn. D, NBR sealings 0100192B Vacuum pump CLASSIC H40, conn. D, NBR sealings, non-return valve 0100195A Vacuum pump CLASSIC H40, conn. D, Viton® sealings 0100194B Vacuum pump CLASSIC H40, conn. D, Viton® sealings, non-return valve 0100197Vacuum pumpsCLASSICORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC, NBR sealings 3201069Sealing kit CLASSIC, Viton® sealings3201069VSealing kit CLASSIC, EPDM sealings3201069EES-kit CLASSIC, G1/8"-G1/4" 0103109Sealing kits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 123


VACUUM PUMPS CLASSICH120 Higher vacuum levels to 100.8 -kPa Use with practicallty zero leakage present andnon-porous applications Available with connection plate in aluminium (AD)and composite PPS (D)Supplied with a push-in connector for compressedair, through-flow silencer and mounting brackets(see Accessories).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 60–65Temperature range ºC -20–80Weight g 690–780MaterialAl, PPS, SS, NBRVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 95 99 -kPa0.60 7.6 8.4 6.6 4.7 2.7 1.5 1.2 0.86 0.62 0.43 0.10 0.050 0.010 100.8EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 95 99 99.5 100.3 -kPa0.60 7.6 0.018 0.033 0.060 0.11 0.18 0.27 0.42 0.62 1.3 2.1 4.2 5.4 8.3 100.8100.6 MPa100.6 MPa88Nl/s6s/l644220010 20 30 40 50 60 70 80 90 95 99-kPaVacuum flow010 20 30 40 50 60 70 80 90 95 99 99.5 100.3-kPaEvacuation time124 Specifications subject to change without notice.


VACUUM PUMPS CLASSICORDERING INFORMATIONDescriptionArt. No.A Vacuum pump CLASSIC H120, conn. AD, NBR sealings 0102131B Vacuum pump CLASSIC H120, conn. AD, NBR sealings, non-return valve 0102132A Vacuum pump CLASSIC H120, conn. D, NBR sealings 0100210B Vacuum pump CLASSIC H120, conn. D, NBR sealings, non-return valve 0100213A Vacuum pump CLASSIC H120, conn. D, Viton® sealings 0100212B Vacuum pump CLASSIC H120, conn. D, Viton® sealings, non-return valve 0100215Vacuum pumpsCLASSICORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC, NBR sealings 3201069Sealing kit CLASSIC, Viton® sealings3201069VSealing kit CLASSIC, EPDM sealings3201069EES-kit CLASSIC, G1/8"-G1/4" 0103109Sealing kits include flap valves, gaskets and compressed-air filters.Specifications subject to change without notice. 125


VACUUM PUMPS CLASSIC MPL150 Large vacuum flow Compact size and light weight compared toconventional mechanical pumps Short evacuation time Good for handling porous materials or if leakageis presentSupplied with vacuum gauge and manometer.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level, with silencer dBA 64–78Temperature range ºC -20–80Weight g 4100–4600MaterialAl, PPS, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 10.5 29 16.2 12.0 7.5 3.8 2.7 1.7 0.76 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 10.5 0.005 0.012 0.021 0.040 0.070 0.12 0.22 75300.6 MPa0.250.6 MPa250.20Nl/s201510s/l0.150.1050.05001020 30 40-kPaVacuum flow5060700.001020 30 40 50-kPaEvacuation time6070126 Specifications subject to change without notice.


VACUUM PUMPS CLASSIC MPORDERING INFORMATIONDescriptionArt. No.Vacuum pump CLASSIC MP L150, conn. V, NBR sealings 0103622Vacuum pump CLASSIC MP L150, conn. V, NBR sealings, complete with mounting brackets and silencer 01041383321413194.3312G1 "G1209Vacuum pumpsCLASSIC MP63532x 1/2"385ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC MP, NBR sealings 0104634For CLASSIC MP 150–240 1x 0104734, for CLASSIC MP 300–480 2x 0104634. Kits include flap valves, gaskets, compressed-air filters andO-rings.2.2Specifications subject to change without notice. 127


VACUUM PUMPS CLASSIC MPL200 Large vacuum flow Compact size and light weight compared toconventional mechanical pumps Short evacuation time Good for handling porous materials or if leakageis presentSupplied with vacuum gauge and manometer.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level, with silencer dBA 64–78Temperature range ºC -20–80Weight g 4100–4600MaterialAl, PPS, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 14.0 38 23.0 16.1 11.2 6.5 4.9 3.0 1.1 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 14.0 0.004 0.009 0.016 0.030 0.050 0.070 0.13 75400.6 MPa0.150.6 MPa35300.12Nl/s2520s/l0.09150,06100,035001020 30 40-kPaVacuum flow5060700.001020 30 40 50-kPaEvacuation time6070128 Specifications subject to change without notice.


VACUUM PUMPS CLASSIC MPORDERING INFORMATIONDescriptionArt. No.Vacuum pump CLASSIC MP L200, conn. V, NBR sealings 0103624Vacuum pump CLASSIC MP L200, conn. V, NBR sealings, complete with mounting brackets and silencer 01041403321413194.3312G1 "G1635209Vacuum pumpsCLASSIC MP32x 1/2"385ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC MP, NBR sealings 0104634For CLASSIC MP 150–240 1x 0104734, for CLASSIC MP 300–480 2x 0104634. Kits include flap valves, gaskets, compressed-air filters andO-rings.2.2Specifications subject to change without notice. 129


VACUUM PUMPS CLASSIC MPL300 Large vacuum flow Compact size and light weight compared toconventional mechanical pumps Short evacuation time Good for handling porous materials or if leakageis presentSupplied with vacuum gauge and manometer.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level, with silencer dBA 64–78Temperature range ºC -20–80Weight g 6400–6900MaterialAl, PPS, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 21.0 46 30 22.8 14.7 9.0 7.1 5.2 3.1 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 21.0 0.004 0.008 0.013 0.020 0.030 0.050 0.080 75500.6 MPa0.080.6 MPa400.070.06Nl/s302010s/l0.050.040.030.020.01001020 30 40-kPaVacuum flow5060700.001020 30 40 50-kPaEvacuation time6070130 Specifications subject to change without notice.


VACUUM PUMPS CLASSIC MPORDERING INFORMATIONDescriptionArt. No.Vacuum pump CLASSIC MP L300, conn. V, NBR sealings 0103626Vacuum pump CLASSIC MP L300, conn. V, NBR sealings, complete with mounting brackets and silencer 0104142Vacuum pumpsCLASSIC MPORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC MP, NBR sealings 0104634For CLASSIC MP 150–240 1x 0104734, for CLASSIC MP 300–480 2x 0104634. Kits include flap valves, gaskets, compressed-air filters andO-rings.Specifications subject to change without notice. 131


VACUUM PUMPS CLASSIC MPL400 Large vacuum flow Compact size and light weight compared toconventional mechanical pumps Short evacuation time Good for handling porous materials or if leakageis presentSupplied with vacuum gauge and manometer.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level, with silencer dBA 64–78Temperature range ºC -20–80Weight g 6400–6900MaterialAl, PPS, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 28 51 39 28 16.4 11.9 9.5 6.7 4 75EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 28 0.004 0.007 0.011 0.020 0.030 0.040 0.060 75600.6 MPa0.060.6 MPa500.05400.04Nl/s30s/l0.03200.02100.01001020 30 40-kPaVacuum flow5060700.001020 30 40 50-kPaEvacuation time6070132 Specifications subject to change without notice.


VACUUM PUMPS CLASSIC MPORDERING INFORMATIONDescriptionArt. No.Vacuum pump CLASSIC MP L400, conn. V, NBR sealings 0103628Vacuum pump CLASSIC MP L400, conn. V, complete with mounting brackets and silencer 0104144Vacuum pumpsCLASSIC MPORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC MP, NBR sealings 0104634For CLASSIC MP 150–240 1x 0104734, for CLASSIC MP 300–480 2x 0104634. Kits include flap valves, gaskets, compressed-air filters andO-rings.Specifications subject to change without notice. 133


VACUUM PUMPS CLASSIC MPM150L Medium vacuum levels to 91 -kPa Compact size and light weight compared toconventional mechanical pumps Operates at only 0.34 MPa Good for applications where little or no leakage ispresentSupplied with vacuum gauge and manometer.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level, with silencer dBA 64–78Temperature range ºC -20–80Weight g 4100–4600MaterialAl, PPS, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 18.0 30 18.8 11.1 9.8 8.2 6.4 3.8 1.3 0.38 890.34 11.3 26 13.8 10.3 6.5 3.8 2.9 2.2 1.5 0.67 0.050 91EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 18.0 0.006 0.014 0.022 0.030 0.050 0.070 0.11 0.35 890.34 11.3 0.007 0.014 0.025 0.050 0.075 0.11 0.17 0.28 0.76 91300.6 MPa0.34 MPa0.80.6 MPa0.34 MPa250.70.6200.5Nl/s15s/l0.4100.30.250.1001020 30 40 50 60-kPaVacuum flow7080900.01020 30 40 50 60-kPaEvacuation time708090134 Specifications subject to change without notice.


VACUUM PUMPS CLASSIC MPORDERING INFORMATIONDescriptionArt. No.Vacuum pump CLASSIC MP M150L, conn. V, NBR sealings 0103762Vacuum pump CLASSIC MP M150L, conn. V, NBR sealings, complete with mounting brackets and silencer 01041603321413194.3312G1 "G1635209Vacuum pumpsCLASSIC MP32x 1/2"385ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC MP, NBR sealings 0104634For CLASSIC MP 150–240 1x 0104734, for CLASSIC MP 300–480 2x 0104634. Kits include flap valves, gaskets, compressed-air filters andO-rings.2.2Specifications subject to change without notice. 135


VACUUM PUMPS CLASSIC MPM200L Medium vacuum levels to 91 -kPa Compact size and light weight compared toconventional mechanical pumps Operates at only 0.34 MPa Good for applications where little or no leakage ispresentSupplied with vacuum gauge and manometer.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level, with silencer dBA 64–78Temperature range ºC -20–80Weight g 4100–4600MaterialAl, PPS, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 24.0 33 21.1 14.6 12.7 10.6 8.2 4.6 1.5 0.57 890.34 15.1 30 17.3 12.5 7.9 5.0 3.9 2.9 2.1 0.95 0.10 91EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 24.0 0.005 0.011 0.018 0.030 0.040 0.050 0.10 0.24 890.34 15.1 0.005 0.011 0.021 0.040 0.060 0.090 0.13 0.21 0.54 91350.6 MPa0.34 MPa0,60.6 MPa0.34 MPa300,5250,4Nl/s201510s/l0,30,250,1001020 30 40 50 60-kPaVacuum flow7080900,01020 30 40 50 60-kPaEvacuation time708090136 Specifications subject to change without notice.


VACUUM PUMPS CLASSIC MPORDERING INFORMATIONDescriptionArt. No.Vacuum pump CLASSIC MP M200L, conn. V, NBR sealings 0103764Vacuum pump CLASSIC MP M200L, conn. V, NBR sealings, complete with mounting brackets and silencer 01041623321413194.3312G1 "G1635209Vacuum pumpsCLASSIC MP32x 1/2"385ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC MP, NBR sealings 0104634For CLASSIC MP 150–240 1x 0104734, for CLASSIC MP 300–480 2x 0104634. Kits include flap valves, gaskets, compressed-air filters andO-rings.2.2Specifications subject to change without notice. 137


VACUUM PUMPS CLASSIC MPORDERING INFORMATIONDescriptionArt. No.Vacuum pump CLASSIC MP M300L, conn. V, NBR sealings 0103766Vacuum pump CLASSIC MP M300L, conn. V, NBR sealings, complete with mounting brackets and silencer 0104164Vacuum pumpsCLASSIC MPORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC MP, NBR sealings 0104634For CLASSIC MP 150–240 1x 0104734, for CLASSIC MP 300–480 2x 0104634. Kits include flap valves, gaskets, compressed-air filters andO-rings.Specifications subject to change without notice. 139


VACUUM PUMPS CLASSIC MPM400L Medium vacuum levels to 91 -kPa Compact size and light weight compared toconventional mechanical pumps Operates at only 0.34 MPa Good for applications where little or no leakage ispresentSupplied with vacuum gauge and manometer.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level, with silencer dBA 64–78Temperature range ºC -20–80Weight g 6400–6900MaterialAl, PPS, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 48 67 40 30 26 20.9 15.7 9.0 2.8 0.95 890.34 30 56 35 24.7 15.2 10.0 7.6 5.7 3.8 1.6 0.19 91EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 48 0.003 0.005 0.008 0.012 0.018 0.026 0.050 0.12 890.34 30 0.003 0.006 0.011 0.020 0.030 0.050 0.070 0.11 0.29 91800.6 MPa0.34 MPa0.300.6 MPa0.34 MPa7060500.250.20Nl/s40s/l0.15300.1020100.05001020 30 40 50 60-kPaVacuum flow7080900.001020 30 40 50 60-kPaEvacuation time708090140 Specifications subject to change without notice.


VACUUM PUMPS CLASSIC MPORDERING INFORMATIONDescriptionArt. No.Vacuum pump CLASSIC MP M400L, conn. V, NBR sealings 0103768Vacuum pump CLASSIC MP M400L, conn. V, NBR sealings, complete with mounting brackets and silencer 0104166Vacuum pumpsCLASSIC MPORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC MP, NBR sealings 0104634For CLASSIC MP 150–240 1x 0104734, for CLASSIC MP 300–480 2x 0104634. Kits include flap valves, gaskets, compressed-air filters andO-rings.Specifications subject to change without notice. 141


VACUUM PUMPS CLASSIC MPH240 Higher vacuum levels to 100.8 -kPa Use with practically zero leakage present andnon-porous applications Compact size and light weight compared toconventional mechanical pumpsSupplied with vacuum gauge and manometer.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level, with silencer dBA 64–78Temperature range ºC -20–80Weight g 4100–4600MaterialAl, PPS, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 95 99 -kPa0.60 15.2 16.8 12.6 8.9 5.0 2.9 2.3 1.8 1.2 0.86 0.19 0.10 0.020 100.8EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 95 99 -kPa0.60 15.2 0.006 0.015 0.030 0.060 0.10 0.15 0.22 0.32 0.64 1.0 2.0 100.8200.6 MPa0.80.6 MPa0.7150,60.5Nl/s10s/l0.40.350.20.1001020 30 40 50 60-kPaVacuum flow7080900.01020 30 40 50 60-kPaEvacuation time708090142 Specifications subject to change without notice.


VACUUM PUMPS CLASSIC MPORDERING INFORMATIONDescriptionArt. No.Vacuum pump CLASSIC MP H240, conn. V, NBR sealings 0103640Vacuum pump CLASSIC MP H240, conn. V, NBR sealings, complete with mounting brackets and silencer 01041563321413194.3312G1 "G1635209Vacuum pumpsCLASSIC MP32x 1/2"385ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC MP, NBR sealings 0104634For CLASSIC MP 150–240 1x 0104734, for CLASSIC MP 300–480 2x 0104634. Kits include flap valves, gaskets, compressed-air filters andO-rings.2.2Specifications subject to change without notice. 143


VACUUM PUMPS CLASSIC MPH480 Higher vacuum levels to 100.8 -kPa Use with practically zero leakage present andnon-porous applications Compact size and light weight compared toconventional mechanical pumpsSupplied with vacuum gauge and manometer.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level, with silencer dBA 64–78Temperature range ºC -20–80Weight g 6400–6900MaterialAl, PPS, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 95 99 -kPa0.60 30 34 26 18.2 10.3 5.9 4.9 3.4 2.3 1.7 0.48 0.19 0.050 100.8EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 95 99 -kPa0.60 30 0.004 0.008 0.016 0.030 0.050 0.080 0.11 0.16 0.33 0.52 0.96 100.8350.6 MPa0.350.6 MPa300.30250.25Nl/s20s/l0.20150.15100.1050.05001020 30 40 50 60-kPaVacuum flow7080900.001020 30 40 50 60-kPaEvacuation time708090144 Specifications subject to change without notice.


VACUUM PUMPS CLASSIC MPORDERING INFORMATIONDescriptionArt. No.Vacuum pump CLASSIC MP H480, conn. V, NBR sealings 0103642Vacuum pump CLASSIC MP H480, conn. V, NBR sealings, complete with mounting brackets and silencer 0104158Vacuum pumpsCLASSIC MPORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit CLASSIC MP, NBR sealings 0104634For CLASSIC MP 150–240 1x 0104734, for CLASSIC MP 300–480 2x 0104634. Kits include flap valves, gaskets, compressed-air filters andO-rings.Specifications subject to change without notice. 145


VACUUM PUMPS MAXIMLL200 Largest compressed-air driven pumpin the market Energy-saving (ES) availableSupplied with built-in silencer, on-off valve, vacuumgauge and pilot control facility.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 72–76Temperature range ºC -20–80Weight g 4900–5300MaterialAl, PPS, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 14.0 48 27 18.1 9.5 4.8 3.3 2.4 1.1 0.48 0.010 91EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 14.0 0.003 0.008 0.014 0.030 0.060 0.10 0.16 0.29 0.82 91500.6 MPa1.00.6 MPa400.8Nl/s30s/l0.6200.4100.2001020 30 40 50 60-kPaVacuum flow7080900.01020 30 40 50 60-kPaEvacuation time708090146 Specifications subject to change without notice.


VACUUM PUMPS MAXIORDERING INFORMATIONDescriptionArt. No.B Vacuum pump MAXI MLL200, NBR sealings 3101056A Vacuum pump MAXI MLL200, NBR sealings, ES 0100741A3B2531/2761367. 193062x 612Vacuum pumpsMAXI47 .5G1ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MAXI MLL200–400, NBR sealings 3101091Sealing kit MAXI MLL200–400, Viton® sealings3101091VSealing kit MAXI MLL200–400, EPDM sealings3101091ESpecifications subject to change without notice. 147


VACUUM PUMPS MAXIORDERING INFORMATIONDescriptionArt. No.B Vacuum pump MAXI MLL400, NBR sealings 3101057A Vacuum pump MAXI MLL400, NBR sealings, ES 0100742A3B2531/2761367. 193062x 612Vacuum pumpsMAXI47 .5G1ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MAXI MLL200–400, NBR sealings 3101091Sealing kit MAXI MLL200–400, Viton® sealings3101091VSealing kit MAXI MLL200–400, EPDM sealings3101091ESpecifications subject to change without notice. 149


VACUUM PUMPS MAXIMLL800 Largest compressed-air driven pumpin the market Energy-saving (ES) availableSupplied with built-in silencer, on-off valve, vacuumgauge and pilot control facility.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 72–76Temperature range ºC -20–80Weight g 7700–8400MaterialAl, PPS, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 56 176 99 67 35 17.6 12.3 8.8 4.2 1.8 0.040 91EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 56 0.0008 0.0018 0.0035 0.008 0.014 0.024 0.040 0.072 0.2 912000.6 MPa0.200.6 MPa1500.15Nl/s100s/l0.10500.05001020 30 40 50 60-kPaVacuum flow7080900.001020 30 40 50 60-kPaEvacuation time708090150 Specifications subject to change without notice.


VACUUM PUMPS MAXIORDERING INFORMATIONDescriptionArt. No.B Vacuum pump MAXI MLL800, NBR sealings 3101058A Vacuum pump MAXI MLL800, NBR sealings, ES 0100743A1 312B37430 85555915132x 6Vacuum pumpsMAXI/4130G2ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MAXI MLL800, NBR sealings 3101092Sealing kit MAXI MLL800, Viton® sealings3101092VSealing kit MAXI MLL800, EPDM sealings3101092ESpecifications subject to change without notice. 151


VACUUM PUMPS MAXIMLL1200 Largest compressed-air driven pumpin the market Energy-saving (ES) availableSupplied with built-in silencer, on-off valve, vacuumgauge and pilot control facility.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 72–76Temperature range ºC -20–80Weight g 9000–9900MaterialAl, PPS, NBR, SSVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.60 84 255 143 97 51 26 17.9 12.8 6.1 2.6 0.050 91EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.60 84 0.0005 0.0012 0.0023 0.0052 0.009 0.016 0.027 0.048 0.14 913000.6 MPa0.150.6 MPa2500.12Nl/s200150s/l0,091000.06500.03001020 30 40 50 60-kPaVacuum flow7080900.001020 30 40 50 60-kPaEvacuation time708090152 Specifications subject to change without notice.


VACUUM PUMPS MAXIORDERING INFORMATIONDescriptionArt. No.B Vacuum pump MAXI MLL1200, NBR sealings 3101059A Vacuum pump MAXI MLL1200, NBR sealings, ES 0100744A1B1 3237440 85555915132x 6Vacuum pumpsMAXI/4130G2ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Sealing kit MAXI MLL1200, NBR sealings 3101099Sealing kit MAXI MLL1200, Viton® sealings3101099VSealing kit MAXI MLL1200, EPDM sealings3101099ESpecifications subject to change without notice. 153


VACUUM PUMPS MAXICONNECTION FLANGE Connection flange facilitates assembly to vacuumline. Suitable for vacuum pumps MAXI.TECHNICAL DATADescriptionMaterialValueAl, PA, SSTECHNICAL DATA, SPECIFICDescription Unit Value3116010 3116015Weight g 500 910ORDERING INFORMATIONDescriptionArt. No.A Connection flange 200–400 3116010B Connection flange 800–1200 3116015AB154 Specifications subject to change without notice.


VACUUM PUMPS MAXICENTRAL EXHAUST Central exhaust is used when an externalsilencer is desired or if a tube/hose is to beconnected for removing the exhaust. Suitable for vacuum pumps MAXI.TECHNICAL DATADescriptionMaterialValueAl, NBR, PETECHNICAL DATA, SPECIFICDescription Unit Value3116017 3116018 3116054Weight g 490 900 1720ORDERING INFORMATIONDescriptionArt. No.Central exhaust MLL200–400 3116017Central exhaust MLL800 3116018Central exhaust MLL1200 3116054Vacuum pumpsMAXISpecifications subject to change without notice. 155


VACUUM PUMPS MAXINON-RETURN VALVE Suitable for vacuum pumps MAXI. To be used together with energy-saving system.TECHNICAL DATADescriptionMaterialValueAl, NBR, Cr, SS, CuZn, PATECHNICAL DATA, SPECIFICDescription Unit Value3116007 3116008Weight g 490 970ORDERING INFORMATIONDescriptionArt. No.A Non-return valve MLL200–400 3116007B Non-return valve MLL800–1200 3116008AB156 Specifications subject to change without notice.


VACUUM PUMPS CLASSICMOUNTING BRACKETS Corrosion-resistant material Included as a set (2 pieces) with each vacuumpumpTECHNICAL DATADescription Unit Value0100505 0103599Weight g 17 210Material SS 2333 Al SS4120-14ORDERING INFORMATIONDescriptionArt. No.A Mounting brackets CLASSIC 0100505B Mounting brackets CLASSIC MP 0103599Vacuum pumpsCLASSICABSpecifications subject to change without notice. 157


Vacuum grippersPIAB VGS3010 – A new product design where high quality DURAFLEX® suction cups are integrated with apatented vacuum cartridge based on the latest COAX® ejector technology. The result is a vacuum “gripper” thatmakes selection, sizing and installation of a vacuum system easier. With the VGS 3010 you will enjoy thebenefits of a more cost-efficient and reliable vacuum system.EFFICIENT MATERIAL HANDLING..............................................................................388APPLICATION EXAMPLES..............................................................................389AID TO SELECTION..............................................................................390SYSTEM SOLUTION EXAMPLES..............................................................................392EXPLANATION OF ORDERING NUMBER..............................................................................393VACUUM GRIPPERSVGS3010 B75P ...................................................394VGS3010 BF80P .................................................396VGS3010 BX35P .................................................398VGS3010 BX52P .................................................400VGS3010 BX75P .................................................402VGS3010 BX52P with stabilizer ............................404VGS3010 BX75P with stabilizer ............................406VGS3010 FC50P .................................................408VGS3010 FC75P .................................................410VGS3010 FC100P ...............................................412VGS3010 F75P ...................................................414VGS3010 F110P .................................................416VGS3010 OB35x90P ...........................................418VGS3010 OB50x140P .........................................420VGS3010 OB65x170P .........................................422VGS3010 OBL40X90P .........................................424VGS3010 OF25x70P ...........................................426VGS3010 OF40x110P .........................................428VGS3010 OF55x150P .........................................430VGS3010 OF70x175P .........................................432VGS3010–LC30 ..................................................434Atmospheric Quick-Release valve – AQR ...................436Check valve VGS3010 .........................................437VGS3010 mounting-kits .......................................438AVP – Adjustable Vacuum Palletiser .........................440AVR – Adjustable Vacuum Rail .................................442Vacuum grippersSpecifications subject to change without notice. 387


VACUUM GRIPPERS VGS3010EFFICIENT MATERIAL HANDLINGINCREASE YOUR PRODUCTIVITY AND REDUCE YOUR COSTS WITH VGS3010 Shorter response time Lower energy cost Higher operation reliability Easy selection and sizing — Knowledge about your specific vacuum flow, level or volume requirements arenot required. Only feed pressure and the material being handled determine the optimal VGS3010 for yourapplication. Improved grip, lifting capacity and wear resistance with DURAFLEX® cups — Provides up to 50% higherfrictional grip as compared to conventional cups.SIMPLE INSTALLATION AND MAINTENANCEThe VGS3010 mounts easily to most extrusionand profile systems. All parts of the VGS3010 areaccessible and interchangeable.FLEXIBLE POSITIONINGOnce installed, the position of the VGS3010 canbe adjusted to accommodate changing handlingconditions.EXCEPTIONAL HANDLING STABILITY WITH STABILIZERThe Stabilizer reduces the need for using manysuction cups for safe and stable lifting. It is usedwith suction cup models BX52P and BX75P.Adjustable supports create exceptional stabilitywhen handling items such as corrugated boxes,boards and sheets. The Stabilizer is also anexcellent aid for handling objects that are hard togrip.Use one VGS with Stabilizer and eliminate theneed for multiple suction cups.Exceptional handling stability with stabilizer388 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010VGS3010 APPLICATION EXAMPLESVGS3010 with DURAFLEX® suction cups can handle these materials more effectively than conventional cup andpump solutions. Corrugated boxes/containers Sheet metal Glass Wood Plastic Small parts assembly and more...Using a VGS3010 with Stabilizer increases theability to handle sheets with sharp convex andconcave surfaces and reduces the quantity of cupsneeded.Handling bottles with one individual VGS3010OBL40x90 per bottle will increase the operationalreliability.Vacuum grippersVGS3010VGS3010 used for palletizing or depalletizing means flexible, quick and easy changeover. The VGS3010eliminates the need to use multiple end-effectors to handle material that changes size or position.Handling configuration 1.Handling configuration 2.Specifications subject to change without notice. 389


VACUUM GRIPPERS VGS3010AID TO SELECTIONBuild a VGS3010 according to your needs.A – CHOOSE SUCTION CUP DESIGNChoose from DURAFLEX® suction cups in sizes 35–110 mm. They are available as flat, bellows, multibellowsand oval cups.VGS3010 consists of DURAFLEX® suction cupsmanufactured in a specially developed polyurethane.DURAFLEX® combines the soft elasticity of rubberwith the exceptional wear resistance of polyurethanewhilst also being non-marking.B – CHOOSE THE HARDNESS OF THE SUCTION CUPMany of the cups are available in a version where thebody and the sealing surface are of differenthardness (dual durometer). This gives the cup bothstrength and stability as well as flexibility to adaptitself to uneven surfaces. Lower or dual durometercups should be used for maximum friction/grip andsealing capability (reduced micro-leakage). Higherdurometer cups should be used for maximum wearresistance and for longer cup life.Molded fitting with removable thread insert. Reducecost by recycling the insert when changing thesuction cup. The suction cup can be locked intoplace from under the cup with a socket-head wrench.SUCTION CUP MATERIAL KEYYellowRedBlueGreenBlack30° Shore A40° Shore A50° Shore A60° Shore A70° Shore ASUCTION CUP OPTION – CHOOSE A CUP WITH STABILIZERFor increased stability and flexibility to handleobjects that are hard to grip with vacuum, a stabilizershould be used. The supports are height-adjustablefor different types of objects. Stabilizer 50 fits suction cup BX52P Stabilizer 75 fits suction cup BX75P390 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010C — CHOOSE VACUUM CARTRIDGE Choose cartridge Pi12-2, a 2-stage ejector with40 Nl/min of vacuum flow, for minimum mountingdimensions when handling non-porous materialsuch as sheet metal or when using smallersuction cups. Choose cartridge Pi12-3, a 3-stage ejector withmore then 90 Nl/min of vacuum flow, for fasterresponse when handling porous material such ascorrugated cardboard or when using large suctioncups. Choose a blind plug (without vacuum cartridge), ifthe unit is to work as a “slave”, i.e. vacuum isgenerated by another VGS3010 unit in thesystem.A non-return valve in the vacuum cartridge should beused to maintain vacuum in a sealed system for ashort period of time to increase safety duringinterruptions of air supply.D — CHOOSE MOUNTING INTERFACE AND MOUNTING ORIENTATIONOption 1 — Flush-mount directly to a plate. Choose a top mount VGS3010 with 4xM4 screws.It gives a strong and non-rotating installation; 5x1/8” plugs are included. This mounting option cannot be usedif you choose a Stabilizer.Option 2–4 — Choose a factory-installed screw that can be mounted in three different positions:Topside, leftside or rightside; 4x1/8" plugs are included. Left or right side mount will give you low installationheight. A profile mounting kit is included for easy attachment to a profile system.Option 2 — Mount the VGS3010 with a M8 16 mm screw.Option 3 — Mount the VGS3010 with a M8 27 mm screw.Option 4 — Mount the VGS 3010 with a M6 22 mm screw.Option 5 –Mount the VGS3010 with a ball joint. Choose a factory-installed ball joint that can be mounted intwo different positions, leftside or rightside, 4x1/8" plugs are included. Left or right side mount will give you lowinstallation height.Option 6 —Mount the VGS3010 with a lock-pin. Choose a factory-installed lock-pin that can be mounted intwo different positions, leftside or rightside; 4x1/8" plugs are included. Left or right side mount will give you lowinstallation height.Option 7 — Mount the VGS3010 with LC30. Choose level compensator LC30 that can be fasten in a grooveof a standard profile. For more information about the LC30, see separate data sheet.Vacuum grippersVGS30101. Flush mount2. M816 mm screw3/4. M8 27 mm / M6 22 mm screw5. Ball joint6. Lock-pin7. Level Compensator LC30 a) Topside, b) leftside, c) rightsideSpecifications subject to change without notice. 391


VACUUM GRIPPERS VGS3010VGS3010 SYSTEM SOLUTION EXAMPLESA profile-mounted VGS3010 can be made nonrotatingby inserting a guide pin in the profile slot.Use the M5 threaded connection on the VGS3010housing.(Guide pin not supplied by PIAB.)Non-rotating guide pinWhen the need for vacuum flow is small, for examplein air-tight systems with small cups, a VGS3010with a vacuum cartridge could provide one or a fewother “slave units”.Suction cups No. 1, 3 and 4 are "slave units" (novacuum cartridge).In order to have efficient cleaning of suction cupfilters and blow-off for quickly releasing parts,compressed air should be connected to one of theextra vacuum ports on the VGS3010.Quick release of parts – a) Vacuum, b) Blow-offFor increased safety and control of the vacuumsystem, a PIAB mini-vacuum switch can easily beconnected to a VGS3010. The switches areavailable as pre-set or with adjustable signal level.Pre-set is recommended to avoid unwanted signallevel changes (adjustment-proof). You can find partnumbers. and technical data for the switches inPIAB’s main catalogue or P3010 Vacuum Pumpsbrochure.Vacuum sensing392 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010EXPLANATION OF VGS3010 ORDERING NUMBER1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAVacuum cartridge Pi12-2ABVacuum cartridge Pi12-3ACVacuum cartridge Pi12-2, non-return valveADVacuum cartridge Pi12-3, non-return valveAE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00M8 16 mm screw top, mounting kit 01M8 16 mm screw right, mounting kit 02M8 16 mm screw left, mounting kit 03M8 27 mm screw top, profile kit 04M8 27 mm screw right, profile kit 05M8 27 mm screw left, profile kit 06M8 27 mm screw top, profile kit 04M6 22 mm screw top, profile kit 07M6 22 mm screw right, profile kit 08M6 22 mm screw left, profile kit 09Ball joint VGS3010 right 11Ball joint VGS3010 left 12Lock-pin VGS3010 right 13Lock-pin VGS3010 left 143. Suction cup with fitting /suction cup with fitting and stabilizer VGS codeNo suction cupBAB75P 30/60° Shore ABBB75P 60° Shore ABCBF80P 30/50° Shore ABDBF80P 60° Shore ABEBX35P 30/60° Shore ABFBX35P 60° Shore ABGBX52P 30/60° Shore ABHBX52P 60° Shore ABIBX75P 30/60° Shore ABJBX75P 60° Shore ABKF75P 30/60° Shore ABLF75P 60° Shore ABMF110P 30/60° Shore ABNF110P 60° Shore ABOFC50P 40° Shore ABPFC50P 60° Shore ABQFC75P 40° Shore ABRFC75P 60° Shore ABSFC100P 40° Shore ABTFC100P 60° Shore ABUOBL40x90P 70° Shore ABVBX52P 30/60° Shore A with Stabilizer 50BWBX52P 60° Shore A with Stabilizer 50BXBX75P 30/60° Shore A with Stabilizer 75BYBX75P 60° Shore A with Stabilizer 75BZOB35X90P 30/60° Shore ACAOB35X90P 60° Shore ACBOB50X140P 30/60° Shore ACCOB50X140P 60° Shore ACDOB65X170P 30/60° Shore ACEOB65X170P 60° Shore ACFOF25X70P 40° Shore ACGOF25X70P 60° Shore ACHOF40X110P 40° Shore ACIOF40X110P 60° Shore ACJOF55X150P 40° Shore ACKOF55X150P 60° Shore ACLOF70X175P 40° Shore ACMOF70X175P 60° Shore ACNBW, BX, BY and BZ are not possible to combine with mounting/orientation 00, 02, 03, 05, 06, 08, 09, 11, 12, 13 or 14.ExampleOrdering numberFromtable 1.Fromtable 2.VGS3010, Pi12-3, M8 27 mm screw top, profile kit, B75P 30/60 Shore VGS3010 AC 04 BBFromtable 3.Vacuum grippersVGS3010Specifications subject to change without notice. 393


VACUUM GRIPPERS VGS3010VGS3010 B75PSUCTION CUP WITH SHORT BELLOWS Suitable for level adjustment and for uneven orporous surfaces such as corrugated boxes/containers. The bellows and sealing surface are available indifferent durometers. This gives the cup bothstrength and stability as well as the flexibility toconform to uneven surfaces. DURAFLEX® cups are made of a revolutionarypolyurethane material that combines the softelasticity of rubber with the exceptional wearresistance of polyurethane. The DURAFLEX® material is non-marking. The suction cups have a molded fitting withremovable G3/8” male thread insert.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range ºC 10–50Weight g 145–167MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 30º/60º SHOREFeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2RECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155 W Plywood 113 113 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 64 64 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 128 149 0.195 0.1870.314 0.47 Nl/s, 155 W Oily steel 118 37 0.195 0.187Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3MPa N N s s0.314 0.47 Nl/s, 155 W Plywood 128 64 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 56 43 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 92 64 0.195 0.1870.314 0.47 Nl/s, 155 W Oily steel 94 23 0.195 0.187FeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3394 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cup with fitting VGS codeNo suction cupBAB75P 30/60° Shore ABBB75P 60° Shore ABCExampleVGS3010 B75P – Pi12-3, M8 27 mm top including profile kit, B75P 30/60º Shore AOrdering numberVGS3010 AC 04 BBab1 3249cd1 3268.839 726 11121 32bcadef23gVacuum grippersVGS30107984Specifications subject to change without notice. 395


VACUUM GRIPPERS VGS3010VGS3010 BF80PSUCTION CUP WITH SHORT BELLOWS The dual durometer BF80P, is suitable for leveladjustment and for uneven and porous surfaces,such as corrugated boxes/containers. Thebellows and the sealing surface have twodifferent durometers. This gives the cup bothstrength and stability as well as the flexibility toconform to uneven surfaces. The green BF80P, is suitable for picking upheavier items, such as sheet metal that has anoily surface. DURAFLEX® cups are made of a revolutionarypolyurethane material that combines the softelasticity of rubber with the exceptional wearresistance of polyurethane. The DURAFLEX® material is non-marking. The suction cup has a molded G3/8” malefitting.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range ºC 10–50Weight g 125–147MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 30º/50º SHOREFeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2RECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155 W Plywood 111 78 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 61 55 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 131 68 0.071 0.0680.314 0.47 Nl/s, 155 W Oily steel 116 40 0.071 0.068Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3MPa N N s s0.314 0.47 Nl/s, 155 W Plywood 51 75 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 54 39 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 50 69 0.071 0.0680.314 0.47 Nl/s, 155 W Oily steel 44 44 0.071 0.068FeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3396 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cup with fitting VGS codeNo suction cupBABF80P 30/50° Shore ABDBF80P 60° Shore ABEExampleVGS3010 BF80P – Pi12-3, M8 27 mm top including profile kit, BF80P 30/50º Shore AOrdering numberVGS3010 AC 04 BDab1 3249cd1 326661239 72 231 32bcad11efgVacuum grippersVGS301084Specifications subject to change without notice. 397


VACUUM GRIPPERS VGS3010VGS3010 BX35PSUCTION CUP WITH 2 ½ BELLOWS Suitable for level adjustment and for uneven andporous surfaces, such as corrugated boxes/containers. The bellows and sealing surface are available indifferent durometers. This gives the cup bothstrength and stability as well as the flexibility toconform to uneven surfaces. DURAFLEX® cups are made of a revolutionarypolyurethane material that combines the softelasticity of rubber with the exceptional wearresistance of polyurethane. The DURAFLEX® material is non-marking. Separate G3/8” male suction cup fitting. A filter support ring in the cup keeps dust out ofthe system. The filter’s materials are polyester(PES41/14) and thermo-plastic-urethane (TPE).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range ºC 10–50Weight g 88–111MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 30°/60º SHOREFeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2RECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155 W Plywood 16 15 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 15 12 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 15 26 0.016 0.0150.314 0.47 Nl/s, 155 W Oily steel 16 6 0.016 0.015Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3MPa N N s a0.314 0.47 Nl/s, 155 W Plywood 16 17 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 16 13 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 16 17 0.016 0.0150.314 0.47 Nl/s, 155 W Oily steel 17 5 0.016 0.015FeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3398 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cup with fitting VGS codeNo suction cupBABX35P 30/60° Shore ABFBX35P 60° Shore ABGExampleVGS3010 BX35P – Pi12-3, M8 27 mm top including profile kit, BX35P 30/60º Shore AOrdering numberVGS3010 AC 04 BFVacuum grippersVGS3010Specifications subject to change without notice. 399


VACUUM GRIPPERS VGS3010VGS3010 BX52PSUCTION CUP WITH 2 ½ BELLOWS Suitable for level adjustment and for uneven andporous surfaces, such as corrugated boxes/containers. The bellows and sealing surface are available indifferent durometers. This gives the cup bothstrength and stability as well as the flexibility toconform to uneven surfaces. DURAFLEX® cups are made of a revolutionarypolyurethane material that combines the softelasticity of rubber with the exceptional wearresistance of polyurethane. The DURAFLEX® material is non-marking. Separate G3/8” male suction cup fitting. A filter support ring in the cup keeps dust out ofthe system. The filter’s materials are polyester(PES41/14) and thermo-plastic-urethane (TPE).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range ºC 10–50Weight g 108–130MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 30°/60º SHOREFeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2RECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155 W Plywood 33 29 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 37 19 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 40 26 0.053 0.0510.314 0.47 Nl/s, 155 W Oily steel 40 14 0.053 0.051Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3MPa N N s s0.314 0.47 Nl/s, 155 W Plywood 36 23 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 30 20 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 37 27 0.053 0.0510.314 0.47 Nl/s, 155 W Oily steel 34 13 0.053 0.051FeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3400 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cup with fitting VGS codeNo suction cupBABX52P 30/60° Shore ABHBX52P 60° Shore ABIExampleVGS3010 BX52P – Pi12-3, M8 27 mm top including profile kit, BX52P 30/60º Shore AOrdering numberVGS3010 AC 04 BHVacuum grippersVGS3010Specifications subject to change without notice. 401


VACUUM GRIPPERS VGS3010VGS3010 BX75PSUCTION CUP WITH 2½ BELLOWS Suitable for level adjustment and for uneven andporous surfaces, such as corrugated boxes/containers. The bellows and sealing surface are available indifferent durometers. This gives the cup bothstrength and stability as well as the flexibility toconform to uneven surfaces. DURAFLEX® cups are made of a revolutionarypolyurethane material that combines the softelasticity of rubber with the exceptional wearresistance of polyurethane. The DURAFLEX® material is non-marking. Molded suction cup fitting with removable threadinsert, male G3/8”. A filter support ring in the cup keeps dust out ofthe system. The filter’s materials are polyester(PES41/14) and thermo-plastic-urethane (TPE).TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range ºC 10–50Weight g 150–173MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 30°/60º SHOREFeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2RECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155 W Plywood 85 56 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 62 28 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 83 75 0.115 0.1110.314 0.47 Nl/s, 155 W Oily steel 85 48 0.115 0.111Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3MPa N N s s0.314 0.47 Nl/s, 155 W Plywood 72 54 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 56 35 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 74 58 0.115 0.1110.314 0.47 Nl/s, 155 W Oily steel 74 32 0.115 0.111FeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3402 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cup with fitting VGS codeNo suction cupBABX75P 30/60° Shore ABJBX75P 60° Shore ABKExampleVGS3010 BX75P – Pi12-3, M8 27 mm top including profile kit, BX75P 30/60º Shore AOrdering numberVGS3010 AC 04 BJVacuum grippersVGS3010Specifications subject to change without notice. 403


VACUUM GRIPPERS VGS3010VGS3010 BX52P WITH STABILIZER Suitable for extra stability when handling plates,sheets or boxes. Reduces the need for extrasuction cups to create stability. The supports are adjustable in order to helphandle difficult-to-grasp objects with vacuum.Rubber pads included for the legs in order toprevent scratches. A filter support ring in the cup keeps dust out ofthe system. The filter’s materials are polyester(PES41/14) and thermo-plastic-urethane (TPE). Separate G3/8” male suction cup fitting.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range ºC 10–50Weight g 201–224MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 30°/60º SHORE WITHSTABILIZERFeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2RECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHORE WITHSTABILIZERMPa N N s s0.314 0.47 Nl/s, 155 W Plywood 32 29 Response time varies based on quality and0.314 0.47 Nl/s, 155 W Corrugated 21 19 porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 33 26 0.053 0.0510.314 0.47 Nl/s, 155 W Oily steel 33 14 0.053 0.051Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3MPa N N s s0.314 0.47 Nl/s, 155 W Plywood 32 23 Response time varies based on quality and0.314 0.47 Nl/s, 155 W Corrugated 23 20 porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 33 27 0.053 0.0510.314 0.47 Nl/s, 155 W Oily steel 33 13 0.053 0.051FeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3404 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS codeM8 16 mm screw top, mounting kit 01M8 27 mm screw top, profile kit 04M6 22 mm screw top, profile kit 07SUCTION CUP WITH FITTING3. Suction cup with fitting VGS codeNo suction cupBABX52P 30/60° Shore A with Stabilizer 50BWBX52P 60° Shore A with Stabilizer 50BXExampleVGS3010 BX52P – Pi12-3, M8 27 mm top including profile kit, BX52P 30/60º Shore A with stabilizer 50Ordering numberVGS3010 AC 04 BWVacuum grippersVGS3010Specifications subject to change without notice. 405


VACUUM GRIPPERS VGS3010VGS3010 BX75P WITH STABILIZER Suitable for extra stability when handling plates,sheets or boxes. Reduces the need for extrasuction cups to create stability. The supports are adjustable in order to helphandle difficult-to-grasp objects with vacuum.Rubber pads included for the legs in order toprevent scratches. A filter support ring in the cup keeps dust out ofthe system. The filter’s materials are polyester(PES41/14) and thermo-plastic-urethane (TPE). Molded suction cup fitting with removable G3/8"male thread insert.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range ºC 10–50Weight g 269–292MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 30°/60º SHORE WITHSTABILIZERFeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2RECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHORE WITHSTABILIZERMPa N N s s0.314 0.47 Nl/s, 155 W Plywood 65 56 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 28 28 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 64 75 0.115 0.1110.314 0.47 Nl/s, 155 W Oily steel 66 48 0.115 0.111Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3MPa N N s s0.314 0.47 Nl/s, 155 W Plywood 70 54 Response time varies based on quality and0.314 0.47 Nl/s, 155 W Corrugated 37 35 porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 73 58 0.115 0.1110.314 0.47 Nl/s, 155 W Oily steel 75 32 0.115 0.111FeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3406 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS codeM8 16 mm screw top, mounting kit 01M8 27 mm screw top, profile kit 04M6 22 mm screw top, profile kit 073. Suction cup with fitting VGS codeNo suction cupBABX75P 30/60° Shore A with Stabilizer 75BYBX75P 60° Shore A with Stabilizer 75BZExampleVGS3010 BX75P – Pi12-3, M8 27 mm top including profile kit, BX75P 30/60º Shore A with stabilizer 75Ordering numberVGS3010 AC 04 BYVacuum grippersVGS3010Specifications subject to change without notice. 407


VACUUM GRIPPERS VGS3010VGS3010 FC50PFLAT, CONCAVE SUCTION CUPS WITH CLEATS Suitable for slightly domed and flat oily surfaces,i.e. handling steel or aluminium sheets in pressprocess. Due to high friction of the rubber material, thesuction cups can withstand high forces at rapidaccelerations in horizontal directions, even onoily surfaces. DURAFLEX® cups are made of a revolutionarypolyurethane material that combines the softelasticity of rubber with the exceptional wearresistance of polyurethane. The DURAFLEX® material is non-marking. Molded G3/8” male suction cup fitting.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range ºC 10–50Weight g 96–119MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 30º/60º SHOREFeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2RECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155 W Plywood 50 61 Response time varies based on quality and0.314 0.47 Nl/s, 155 W Corrugated 34 45 porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 57 70 0.018 0.0170.314 0.47 Nl/s, 155 W Oily steel 46 16 0.018 0.017Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3MPa N N s s0.314 0.47 Nl/s, 155 W Plywood 50 53 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 36 42 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 55 58 0.018 0.0170.314 0.47 Nl/s, 155 W Oily steel 51 44 0.018 0.017FeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3408 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cup with fitting VGS codeNo suction cupBAFC50P 40° Shore ABPFC50P 60° Shore ABQExampleVGS3010 FC50P – Pi12-3, M8 27 mm top including profile kit, FC50P 40º Shore AOrdering numberVGS3010 AC 04 BPVacuum grippersVGS3010Specifications subject to change without notice. 409


VACUUM GRIPPERS VGS3010VGS3010 FC75PFLAT, CONCAVE SUCTION CUPS WITH CLEATS Suitable for slightly domed and flat oily surfaces,i.e. handling steel or aluminium sheets in pressprocess. Due to high friction of the rubber material, thesuction cups can withstand high forces at rapidaccelerations in horizontal directions, even onoily surfaces. DURAFLEX® cups are made of a revolutionarypolyurethane material that combines the softelasticity of rubber with the exceptional wearresistance of polyurethane. The DURAFLEX® material is non-marking. Molded suction cup fitting with removable G3/8"male thread insert.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range ºC 10–50Weight g 111–133MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREFeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2RECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155 W Plywood 117 121 Response time varies based on quality.0.314 0.47 Nl/s, 155 W Corrugated 59 58 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 123 90 0.053 0.0510.314 0.47 Nl/s, 155 W Oily steel 113 34 0.053 0.051Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3MPa N N s s0.314 0.47 Nl/s, 155 W Plywood 102 117 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 57 71 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 100 131 0.053 0.0510.314 0.47 Nl/s, 155 W Oily steel 100 63 0.053 0.051FeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3410 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cup with fitting VGS codeNo suction cupBAFC75P 40° Shore ABRFC75P 60° Shore ABSExampleVGS3010 FC75P – Pi12-3, M8 27 mm top including profile kit, FC75P 40º Shore AOrdering numberVGS3010 AC 04 BRVacuum grippersVGS3010Specifications subject to change without notice. 411


VACUUM GRIPPERS VGS3010VGS3010 FC100PFLAT, CONCAVE SUCTION CUPS WITH CLEATS Suitable for slightly domed and flat oily surfaces,i.e. handling steel or aluminium sheets in pressprocess. Due to high friction of the rubber material, thesuction cups can withstand high forces at rapidaccelerations in horizontal directions, even onoily surfaces. DURAFLEX® cups are made of a revolutionarypolyurethane material that combines the softelasticity of rubber with the exceptional wearresistance of polyurethane. The DURAFLEX® material is non-marking. Molded suction cup fitting with removable G3/8"male thread insert.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range ºC 10–50Weight g 162–184MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT-IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 40º SHOREFeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2RECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155 W Plywood 221 178 Response time varies based on quality and0.314 0.47 Nl/s, 155 W Corrugated 71 87 porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 255 238 0.142 0.1360.314 0.47 Nl/s, 155 W Oily steel 217 52 0.142 0.136Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3MPa N N s s0.314 0.47 Nl/s, 155 W Plywood 189 215 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 60 100 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 208 230 0.142 0.1360.314 0.47 Nl/s, 155 W Oily steel 174 56 0.142 0.136FeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3412 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cup with fitting VGS codeNo suction cupBAFC100P 40° Shore ABTFC100P 60° Shore ABUExampleVGS3010 FC100P – Pi12-3, M8 27 mm top including profile kit, FC100P 40º Shore AOrdering numberVGS3010 AC 04 BTVacuum grippersVGS3010Specifications subject to change without notice. 413


VACUUM GRIPPERS VGS3010VGS3010 F75PFLAT SUCTION CUPS WITH CLEATS Suitable for all flat and rough surfaces. Good stability and little inherent movement dueto the high friction of the rubber material, thesuction cups can withstand high forces at rapidaccelerations in horizontal directions, even onoily surfaces. Recommended when the lifting force is parallel tothe surface of the object. The suction cups are available in differentdurometers. This gives the cup both strength andstability as well as the flexibility to conform torough surfaces. DURAFLEX® cups are made of a revolutionarypolyurethane material that combines the softelasticity of rubber with the exceptional wearresistance of polyurethane. The DURAFLEX® material is non-marking. The suction cups have a molded fitting withremovable G3/8” male thread insert.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range ºC 10–50Weight g 128–150MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 30°/60º SHOREFeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2RECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155 W Plywood 140 111 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 61 33 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 165 85 0.034 0.0320.314 0.47 Nl/s, 155 W Oily steel 163 33 0.034 0.032Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3MPa N N s s0.314 0.47 Nl/s, 155 W Plywood 144 151 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 64 62 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 160 74 0.034 0.0320.314 0.47 Nl/s, 155 W Oily steel 142 33 0.034 0.032FeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3414 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cup with fitting VGS codeNo suction cupBAF75P 30/60° Shore ABLF75P 60° Shore ABMExampleVGS3010 F75P – Pi12-3, M8 27 mm top including profile kit, F75P 30/60º Shore AOrdering numberVGS3010 AC 04 BLVacuum grippersVGS3010Specifications subject to change without notice. 415


VACUUM GRIPPERS VGS3010VGS3010 F110PFLAT SUCTION CUPS WITH CLEATS Suitable for all flat and rough surfaces. Good stability and little inherent movement dueto the high friction of the rubber material, thesuction cups can withstand high forces at rapidaccelerations in horizontal directions, even onoily surfaces. Recommended when the lifting force is parallel tothe surface of the object. The suction cups are available in differentdurometers. This gives the cup both strength andstability as well as the flexibility to conform torough surfaces. DURAFLEX® cups are made of a revolutionarypolyurethane material that combines the softelasticity of rubber with the exceptional wearresistance of polyurethane. The DURAFLEX® material is non-marking. The suction cups have a molded fitting withremovable G3/8” male thread insert.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range ºC 10–50Weight g 210–232MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 30°/60º SHOREFeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2RECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155 W Plywood 310 300 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 114 110 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 352 332 0.106 0.1020.314 0.47 Nl/s, 155 W Oily steel 304 161 0.106 0.102Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3MPa N N s s0.314 0.47 Nl/s, 155 W Plywood 317 274 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 107 105 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 335 308 0.106 0.1020.314 0.47 Nl/s, 155 W Oily steel 304 95 0.106 0.102FeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3416 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cup with fitting VGS codeNo suction cupBAF110P 30/60° Shore ABNF110P 60° Shore ABOExampleVGS3010 F110P – Pi12-3, M8 27 mm top including profile kit, F110P 30/60º Shore AOrdering numberVGS3010 AC 04 BNVacuum grippersVGS3010Specifications subject to change without notice. 417


VACUUM GRIPPERS VGS3010VGS3010 OB35X90P Suitable for level adjustment. Can handle objectwith heigh differences and varying shapes, forexample embossed or corrugated plates. Lifting movement to separate small and thinobjetcs. In the two colored suction cup, the bellows andthe sealing lip are of different hardness, whichmakes the suction cup strong and stable and, atthe same time, soft and flexible DURAFLEX® are Suction cups manufactured in aspecially developed material that features theelesticity of rubber and wear resistance ofpolyurethane. The material does not leave anymarks on the objects handled. Separate G3/8" male suction cup fitting.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range °C 10–50Weight g 151-355MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 30/60º SHOREFeedpressureAir consumption andcompressor power, continuousoperationMaterial to behandled(see tablebelow)Recommendedperpendicularload with safetyfactor 2RECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155W Plywood 56.5 71.5 Response time varies based onquality0.314 0.47 Nl/s, 155W Corrugated 39 52.5 and porosity of handledmaterial.0.314 0.47 Nl/s, 155W Dry steel 78.5 106 0.064 0.0610.314 0.47 Nl/s, 155W Oily steel 63.5 39 0.064 0.061Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Recommendedparallel (shear)load with safetyfactor 2Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Responsetime to50 -kPa withPi12-2Responsetime to50 -kPa withPi12-3MPa N N s s0.314 0.47 Nl/s, 155W Plywood 67.5 86.5 Response time varies based onquality0.314 0.47 Nl/s, 155W Corrugated 44 61.5 and porosity of handledmaterial.0.314 0.47 Nl/s, 155W Dry steel 78.5 106.5 0.064 0.0610.314 0.47 Nl/s, 155W Oily steel 51 30 0.064 0.061FeedpressureAir consumption andcompressor power, continuousoperationMaterial to behandled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Responsetime to50 -kPa withPi12-2Responsetime to50 -kPa withPi12-3418 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cups with fitting VGS codeNo suction cupBAOB35X90P 30/60° Shore ACAOB35X90P 60° Shore ACBExampleVGS3010 OB35x90P – Pi12-3, M8 27 mm top including profile kit, OB35x90P 30/60° Shore AOrdering numberVGS3010 AC 04 CAVacuum grippersVGS3010Specifications subject to change without notice. 419


VACUUM GRIPPERS VGS3010VGS3010 OB50X140P Suitable for level adjustment. Can handle objectwith heigh differences and varying shapes, forexample embossed or corrugated plates. Lifting movement to separate small and thinobjetcs. In the two colored suction cup, the bellows andthe sealing lip are of different hardness, whichmakes the suction cup strong and stable and, atthe same time, soft and flexible DURAFLEX® are Suction cups manufactured in aspecially developed material that features theelesticity of rubber and wear resistance ofpolyurethane. The material does not leave anymarks on the objects handled. Separate G3/8" male suction cup fittingTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range °C 10–50Weight g 236-440MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 30°/60º SHOREFeedpressureAir consumption andcompressor power, continuousoperationMaterial to behandled(see tablebelow)Recommendedperpendicularload with safetyfactor 2RECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155W Plywood 141 168.5 Response time varies based onquality0.314 0.47 Nl/s, 155W Corrugated 56 103 and porosity of handledmaterial.0.314 0.47 Nl/s, 155W Dry steel 183.5 196.5 0.168 0.1620.314 0.47 Nl/s, 155W Oily steel 182 136 0.168 0.162Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Recommendedparallel (shear)load with safetyfactor 2Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Responsetime to50 -kPa withPi12-2Responsetime to50 -kPa withPi12-3MPa N N s s0.314 0.47 Nl/s, 155W Plywood 150 175.5 Response time varies based onquality0.314 0.47 Nl/s, 155W Corrugated 67 83.5 and porosity of handledmaterial.0.314 0.47 Nl/s, 155W Dry steel 182.5 173.5 0.168 0.1620.314 0.47 Nl/s, 155W Oily steel 153.5 169.5 0.168 0.162FeedpressureAir consumption andcompressor power, continuousoperationMaterial to behandled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Responsetime to50 -kPa withPi12-2Responsetime to50 -kPa withPi12-3420 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cups with fitting VGS codeNo suction cupBAOB50X140P 30/60° Shore ACCOB50X140P 60° Shore ACDExampleVGS3010 OB50x140P – Pi12-3, M8 27 mm top including profile kit, OB50x140P 30/60° Shore AOrdering numberVGS3010 AC 04 CCVacuum grippersVGS3010Specifications subject to change without notice. 421


VACUUM GRIPPERS VGS3010VGS3010 OB65X170P Suitable for level adjustment. Can handle objectwith heigh differences and varying shapes, forexample embossed or corrugated plates. Lifting movement to separate small and thinobjetcs. In the two colored suction cup, the bellows andthe sealing lip are of different hardness, whichmakes the suction cup strong and stable and, atthe same time, soft and flexible DURAFLEX® are Suction cups manufactured in aspecially developed material that features theelesticity of rubber and wear resistance ofpolyurethane. The material does not leave anymarks on the objects handled. Separate G3/8" male suction cup fittingTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range °C 10–50Weight g 346-550MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 30°/60º SHOREFeedpressureAir consumption andcompressor power, continuousoperationMaterial to behandled(see tablebelow)Recommendedperpendicularload with safetyfactor 2RECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155W Plywood 180 195 Response time varies based onquality0.314 0.47 Nl/s, 155W Corrugated 78 130 and porosity of handledmaterial.0.314 0.47 Nl/s, 155W Dry steel 272.5 300 0.310 0.2890.314 0.47 Nl/s, 155W Oily steel 260 200 0.310 0.289Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Recommendedparallel (shear)load with safetyfactor 2Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Responsetime to50 -kPa withPi12-2Responsetime to50 -kPa withPi12-3MPa N N s s0.314 0.47 Nl/s, 155W Plywood 230 266 Response time varies based onquality0.314 0.47 Nl/s, 155W Corrugated 79 100.5 and porosity of handledmaterial.0.314 0.47 Nl/s, 155W Dry steel 265.5 259.5 0.310 0.2980.314 0.47 Nl/s, 155W Oily steel 239 146 0.310 0.298FeedpressureAir consumption andcompressor power, continuousoperationMaterial to behandled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Responsetime to50 -kPa withPi12-2Responsetime to50 -kPa withPi12-3422 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cups with fitting VGS codeNo suction cupBAOB65X170P 30/60° Shore ACEOB65X170P 60° Shore ACFExampleVGS3010 OB65x170P – Pi12-3, M8 27 mm top including profile kit, OB65x170P 30/60° Shore AOrdering numberVGS3010 AC 04 CEVacuum grippersVGS3010Specifications subject to change without notice. 423


VACUUM GRIPPERS VGS3010VGS3010 OBL40X90POVAL SUCTION CUP WITH 4 BELLOWS Suitable for handling elongated and sharp curvedsurfaces, such as bottles and other cylindricalparts. Strengthening rings make the suction cup stable. DURAFLEX® cups are made of a revolutionarypolyurethane material that combines the softelasticity of rubber with the exceptional wearresistance of polyurethane. The DURAFLEX® material is non-marking. The suction cups have a molded fitting withremovable G3/8” male thread insert.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range ºC 10–50Weight g 181–204MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 70º SHOREFeedpressureAir consumptionand compressorpower, continuousoperationMaterial tobe handled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2MPa N N s s0.314 0.47 Nl/s, 155 W Plywood 74 69 Response time varies based on quality0.314 0.47 Nl/s, 155 W Corrugated 51 47 and porosity of handled material.0.314 0.47 Nl/s, 155 W Dry steel 91 70 0.186 0.1790.314 0.47 Nl/s, 155 W Oily steel 74 19 0.186 0.179Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Response time to50 -kPa with Pi12-2Response time to50 -kPa with Pi12-3424 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cup with fitting VGS codeNo suction cupBAOBL40x90P 70° Shore ABVExampleVGS3010 OBL40x90P – Pi12-3, M8 27 mm top including profile kit, OBL40x90P 70º Shore AOrdering numberVGS3010 AC 04 BVVacuum grippersVGS3010Specifications subject to change without notice. 425


VACUUM GRIPPERS VGS3010VGS3010 OF25X70P Suitable for all flat and rough surfaces. Fair stability and little inherent movement. Recommended when the lifting force is parallel tothe surface of the object. Cleats prevent thin, sensitive objects from beingdeformed and give extra friction when the liftingforce is prallel to the surface of the object. DURAFLEX® are Suction cups manufactured in aspecially developed material that features theelesticity of rubber and wear resistance ofpolyurethane. The material does not leave anymarks on the objects handled. Separate G3/8" male suction cup fitting.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range °C 10–50Weight g 105-310MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 40º SHOREFeedpressureAir consumption andcompressor power, continuousoperationMaterial to behandled(see tablebelow)Recommendedperpendicularload with safetyfactor 2RECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155W Plywood 44 48.5 Response time varies based onquality0.314 0.47 Nl/s, 155W Corrugated 35.5 37.5 and porosity of handledmaterial.0.314 0.47 Nl/s, 155W Dry steel 59 81 0.011 0.0100.314 0.47 Nl/s, 155W Oily steel 52.5 28.5 0.011 0.010Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Recommendedparallel (shear)load with safetyfactor 2Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Responsetime to50 -kPa withPi12-2Responsetime to50 -kPa withPi12-3MPa N N s s0.314 0.47 Nl/s, 155W Plywood 46 44.5 Response time varies based onquality0.314 0.47 Nl/s, 155W Corrugated 35.5 37 and porosity of handledmaterial.0.314 0.47 Nl/s, 155W Dry steel 54 52.5 0.010 0.0100.314 0.47 Nl/s, 155W Oily steel 50 27 0.011 0.010FeedpressureAir consumption andcompressor power, continuousoperationMaterial to behandled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Responsetime to50 -kPa withPi12-2Responsetime to50 -kPa withPi12-3426 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cups with fitting VGS codeNo suction cupBAOF25X70P 40° Shore ACGOF25X70P 60° Shore ACHExampleVGS3010 OF25x70P – Pi12-3, M8 27 mm top including profile kit, OF25x70P 40° Shore AOrdering numberVGS3010 AC 04 CGVacuum grippersVGS3010Specifications subject to change without notice. 427


VACUUM GRIPPERS VGS3010VGS3010 OF40X110P Suitable for all flat and rough surfaces. Fair stability and little inherent movement. Recommended when the lifting force is parallel tothe surface of the object. Cleats prevent thin, sensitive objects from beingdeformed and give extra friction when the liftingforce is prallel to the surface of the object. DURAFLEX® are Suction cups manufactured in aspecially developed material that features theelesticity of rubber and wear resistance ofpolyurethane. The material does not leave anymarks on the objects handled. Separate G3/8" male suction cup fitting.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range °C 10–50Weight g 151-355MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 40º SHOREFeedpressureAir consumption andcompressor power, continuousoperationMaterial to behandled(see tablebelow)Recommendedperpendicularload with safetyfactor 2RECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155W Plywood 129.5 131.5 Response time varies based onquality0.314 0.47 Nl/s, 155W Corrugated 45.5 77 and porosity of handledmaterial.0.314 0.47 Nl/s, 155W Dry steel 151.5 205.5 0.037 0.0360.314 0.47 Nl/s, 155W Oily steel 139.5 58.5 0.037 0.036Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Recommendedparallel (shear)load with safetyfactor 2Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Responsetime to50 -kPa withPi12-2Responsetime to50 -kPa withPi12-3MPa N N s s0.314 0.47 Nl/s, 155W Plywood 123 119.5 Response time varies based onquality0.314 0.47 Nl/s, 155W Corrugated 62 50.5 and porosity of handledmaterial.0.314 0.47 Nl/s, 155W Dry steel 145.5 148.5 0.037 0.0360.314 0.47 Nl/s, 155W Oily steel 123.5 36 0.037 0.036FeedpressureAir consumption andcompressor power, continuousoperationMaterial to behandled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Responsetime to50 -kPa withPi12-2Responsetime to50 -kPa withPi12-3428 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cups with fitting VGS codeNo suction cupBAOF40X110P 40° Shore ACIOF40X110P 60° Shore ACJExampleVGS3010 OF40x110P – Pi12-3, M8 27 mm top including profile kit, OF40x110P 40° Shore AOrdering numberVGS3010 AC 04 CIVacuum grippersVGS3010Specifications subject to change without notice. 429


VACUUM GRIPPERS VGS3010VGS3010 OF55X150P Suitable for all flat and rough surfaces. Fair stability and little inherent movement. Recommended when the lifting force is parallel tothe surface of the object. Cleats prevent thin, sensitive objects from beingdeformed and give extra friction when the liftingforce is prallel to the surface of the object. DURAFLEX® are Suction cups manufactured in aspecially developed material that features theelesticity of rubber and wear resistance ofpolyurethane. The material does not leave anymarks on the objects handled. Separate G3/8" male suction cup fitting.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range °C 10–50Weight g 216-420MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 40º SHOREFeedpressureAir consumption andcompressor power, continuousoperationMaterial to behandled(see tablebelow)Recommendedperpendicularload with safetyfactor 2RECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155W Plywood 208 231.5 Response time varies based onquality0.314 0.47 Nl/s, 155W Corrugated 90.5 113 and porosity of handledmaterial.0.314 0.47 Nl/s, 155W Dry steel 279 238 0.065 0.0630.314 0.47 Nl/s, 155W Oily steel 270 175.5 0.065 0.063Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Recommendedparallel (shear)load with safetyfactor 2Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Responsetime to50 -kPa withPi12-2Responsetime to50 -kPa withPi12-3MPa N N s s0.314 0.47 Nl/s, 155W Plywood 214 213.5 Response time varies based onquality0.314 0.47 Nl/s, 155W Corrugated 87.5 115.5 and porosity of handledmaterial.0.314 0.47 Nl/s, 155W Dry steel 258 241 0.065 0.0630.314 0.47 Nl/s, 155W Oily steel 247 160 0.065 0.063FeedpressureAir consumption andcompressor power, continuousoperationMaterial to behandled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Responsetime to50 -kPa withPi12-2Responsetime to50 -kPa withPi12-3430 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cups with fitting VGS codeNo suction cupBAOF55X150P 40° Shore ACKOF55X150P 60° Shore ACLExampleVGS3010 OF55x150P – Pi12-3, M8 27 mm top including profile kit, OF55x150P 40° Shore AOrdering numberVGS3010 AC 04 CKVacuum grippersVGS3010Specifications subject to change without notice. 431


VACUUM GRIPPERS VGS3010VGS3010 OF70X175P Suitable for all flat and rough surfaces. Fair stability and little inherent movement. Recommended when the lifting force is parallel tothe surface of the object. Cleats prevent thin, sensitive objects from beingdeformed and give extra friction when the liftingforce is prallel to the surface of the object. DURAFLEX® are Suction cups manufactured in aspecially developed material that features theelesticity of rubber and wear resistance ofpolyurethane. The material does not leave anymarks on the objects handled. Separate G3/8" male suction cup fitting.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range °C 10–50Weight g 285-490MaterialPP, PA, NBR, AL, SS, PURECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 40º SHOREFeedpressureAir consumption andcompressor power, continuousoperationMaterial to behandled(see tablebelow)Recommendedperpendicularload with safetyfactor 2RECOMMENDED LOAD WITH BUILT IN SAFETY FACTOR OF 2 AND RESPONSE TIME, 60º SHOREMPa N N s s0.314 0.47 Nl/s, 155W Plywood 317 285 Response time varies based onquality0.314 0.47 Nl/s, 155W Corrugated 72 125 and porosity of handledmaterial.0.314 0.47 Nl/s, 155W Dry steel 435 392.5 0.142 0.1360.314 0.47 Nl/s, 155W Oily steel 405 252.5 0.142 0.136Remark: The compressor power is calculated according to: 5.5 W consumed electric power per producedNl/min compressed air, valid for a normally sized 7 bar compressor.NOTE: The response times are not valid for Level Compensator LC30.Recommendedparallel (shear)load with safetyfactor 2Material definition: Corrugated cardboard = B Flute 3 mm, 80 Gurley seconds.Responsetime to50 -kPa withPi12-2Responsetime to50 -kPa withPi12-3MPa N N s s0.314 0.47 Nl/s, 155W Plywood 320 350 Response time varies based onquality0.314 0.47 Nl/s, 155W Corrugated 117.5 125 and porosity of handledmaterial.0.314 0.47 Nl/s, 155W Dry steel 387.5 340 0.142 0.1360.314 0.47 Nl/s, 155W Oily steel 360 200 0.142 0.136FeedpressureAir consumption andcompressor power, continuousoperationMaterial to behandled(see tablebelow)Recommendedperpendicularload with safetyfactor 2Recommendedparallel (shear)load with safetyfactor 2Responsetime to50 -kPa withPi12-2Responsetime to50 -kPa withPi12-3432 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAb Vacuum cartridge Pi12-2 ABa Vacuum cartridge Pi12-3 ACc Vacuum cartridge Pi12-2, non-return valve ADd Vacuum cartridge Pi12-3, non-return valve AE2. Mounting / orientation VGS code4x M4 screw top, 5x plug G1/8", flush mount 00f M8 16 mm screw top, mounting kit 01g M8 16 mm screw right, mounting kit 02e M8 16 mm screw left, mounting kit 03f M8 27 mm screw top, profile kit 04g M8 27 mm screw right, profile kit 05e M8 27 mm screw left, profile kit 06f M6 22 mm screw top, profile kit 07g M6 22 mm screw right, profile kit 08e M6 22 mm screw left, profile kit 09g Ball joint VGS3010 right 11e Ball joint VGS3010 left 12g Lock-pin VGS3010 right 13e Lock-pin VGS3010 left 14Level Compensator LC30 15More info about LC30 see separate data sheet3. Suction cups with fitting VGS codeNo suction cupBAOF70X175P 40° Shore ACMOF70X175P 60° Shore ACNExampleVGS3010 OF70x175P – Pi12-3, M8 27 mm top including profile kit, OF70x175P 40° Shore AOrdering numberVGS3010 AC 04 CMVacuum grippersVGS3010Specifications subject to change without notice. 433


VACUUM GRIPPERS VGS3010VGS3010–LC30 The LC30 is tailor made as a mounting option forthe Vacuum Gripper System, VGS3010 Developed for use with standard profile systems. Easy installation with the option of fineadjustments and positioning of the suction cup. Non-rotational for use with, for example, ovalsuction cups. Quiet and reliable level compensation with loadprotection and shock absorbtion.TECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 65–74Temperature range ºC 10–50Weight range g 299-578MaterialPP, PA, NBR, AL, SS, PUSpring force N 5–42Stroke mm 30Volume LC30, internal cm 3 5Maximum load, vertical N 700Adjustable in height mm 12Adjustable in rotational direction º 0–360ORDERING INFORMATION1. Vacuum cartridge VGS codeNo vacuum cartridge (slave unit with blind plug M14x1)AAVacuum cartridge Pi12-2ABVacuum cartridge Pi12-3ACVacuum cartridge Pi12-2, non-return valveADVacuum cartridge Pi12-3, non-return valveAE2. LC30 VGS codeLevel Compensator LC30 15LC 30 is delivered with two MC6S M6x45 fzb screws.3. Suction cups with fitting Y X VGSCodeNo suction cup 111 — BAB75P 30/60° Shore A 149.8 Ø79 BBB75P 60° Shore A 149.8 Ø79 BCBF80P 30/50° Shore A 147.5 Ø84 BDBF80P 60° Shore A 147.5 Ø84 BEBX35P 30/60° Shore A 143.8 Ø37 BFBX35P 60° Shore A 143.8 Ø37 BGBX52P 30/60° Shore A 156 Ø53 BHBX52P 60° Shore A 156 Ø53 BIBX75P 30/60° Shore A 162.7 Ø77.5 BJBX75P 60° Shore A 162.7 Ø77.5 BKF75P 30/60° Shore A 125.5 Ø77 BLF75P 60° Shore A 125.5 Ø77 BMF110P 30/60° Shore A 131.5 Ø115 BN434 Specifications subject to change without notice.


VACUUM GRIPPERS VGS30103. Suction cups with fitting Y X VGSCodeF110P 60° Shore A 131.5 Ø115 BOFC50P 40° Shore A 134.5 Ø50 BPFC50P 60° Shore A 134.5 Ø50 BQFC75P 40° Shore A 135 Ø75 BRFC75P 60° Shore A 135 Ø75 BSFC100P 40° Shore A 139.5 Ø100 BTFC100P 60° Shore A 139.5 Ø100 BUOBL40x90P 70° Shore A 175 45x95 BVOB35X90P 30/60° Shore A 138.25 42.4x97.4 CAOB35X90P 60° Shore A 138.25 42.4x97.4 CBOB50X140P 30/60° Shore A 145.5 59x149 CCOB50X140P 60° Shore A 145.5 59x149 CDOB65X170P 30/60° Shore A 152.5 76x181 CEOB65X170P 60° Shore A 152.5 76x181 CFOF25X70P 40° Shore A 124 27.3x72.3 CGOF25X70P 60° Shore A 124 27.3x72.3 CHOF40X110P 40° Shore A 128.5 43x113 CIOF40X110P 60° Shore A 128.5 43x113 CJOF55X150P 40° Shore A 132 59x154 CKOF55X150P 60° Shore A 132 59x154 CLOF70X175P 40° Shore A 136 75x180 CMOF70X175P 60° Shore A 136 75x180 CNVacuum grippersVGS3010For more information about LC30, see separate data sheet in SUCTION CUPS ACCESSORIES chapter.Specifications subject to change without notice. 435


VACUUM GRIPPERS VGS3010ATMOSPHERIC QUICK-RELEASE VALVE – AQR Equalizes pressure in vacuum gripper systems toprovide fast release of product Consumes no additional compressed air ON/OFF activated simultaneously with theVacuum Gripper System (VGS) Simple installation to the vacuum chamber of theVGS pump No additional controls required — use single 3/2control valve for VGS and AQRTECHNICAL DATADescription Unit ValueFeed pressure MPa 0.2–0.7Temperature range °C 10–50Weight g 20Atmospheric flow, average Nl/s 3.3MaterialCuZn, PUR, NBRRecommended max. distance between AQR and controlvalve for optimal performancem 1.5ORDERING INFORMATIONDescriptionArt. No.Atmospheric quick-release valve – AQR 0111236A=AQR, B=Vacuum pump, C=Control valve, D=Rec. max. 1.5m436 Specifications subject to change without notice.


ACCESSORIESCHECK VALVE VGS3010 Simple installation to any 1/8” VGS accessoryport Prevents vacuum from being pulled through blowofflines, which means faster response andcompletely independent VGS units. Suitable in applications where cleaning of thelines or suction cup filter is necessaryTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Feed pressure, min., breakaway blow-off MPa 0.25MaterialAL, NBR, PATemperature range °C -10–80Weight g 6.25Flow, max. Nl/s 7ORDERING INFORMATIONDescriptionArt. No.Check valve VGS3010 0110457G1 "295./8AccessoriesSpecifications subject to change without notice. 437


VACUUM GRIPPERS VGS3010VGS3010 MOUNTING-KITS Fits standard robot end-of-arm tooling interfaces Easy attachment to standard extrusion andprofile systems Flexible positioning Quick setup and change-over Durable and non-rotating installationTECHNICAL DATA, SPECIFICDescription Unit Value0106915 0106927 0106949 0108488 0108731 0108734Material SS, NBR SS, PA, NBR Al, SS, Steel, NBR Al, SS, Steel, NBR AL, SS, NBR AL, SS, NBRWeight g 24 24 36 22 46 29438 Specifications subject to change without notice.


VACUUM GRIPPERS VGS3010ORDERING INFORMATIONDescriptionArt. No.A 4x M4 screw top, 5x plug G1/8", flush mount 00B M8 16 mm screw, mounting kit 0106927C M8 27 mm screw, profile kit 0106949D M6 22 mm screw, profile kit 0108488E Ball joint VGS3010 0108731F Lock-pin VGS3010 0108734B–D 4x plug G1/8" included.A B C DEFVacuum grippersVGS3010Specifications subject to change without notice. 439


VACUUM GRIPPERS PALLETISINGAVP – ADJUSTABLE VACUUM PALLETISER Lightweight design Simple X/Y axis adjustability Flexible modular design Energy saving from COAX® vacuum technologyTECHNICAL DATADescription Unit Value2 rails 4 rails 6 railsWeight, AVP BX75P kg 7.7 14.2 20.8Weight, AVP BX110P kg 8.7 16.2 23.7Temperature range °C 10–50MaterialAL,PUR,POM,SS,Fe,CuZn,PP,NBRT-slot opening dimension mm 10LIFTING FORCES PER CUPSuction cup Material to Lifting forces vertical to the surface, N,Lifting forces parallel to the surface, N,modelbe handledat vacuum levelat vacuum level20 -kPa 60 -kPa 90 -kPa 20 -kPa 60 -kPa 90 -kPaBX75P Corrugated 39 114 — 36 57 —BX75P Dry steel 38 103 153 39 70 95BX110P Corrugated 93 173* — 68 139* —BX110P Dry steel 143 337 402 78 177 199* Lifting forces at maximum vacuum level 56 -kPaLIFTING FORCES & RESPONSE TIME PER CUPSuction cup Feed pressure Material to Lifting forces vertical Lifting forces parallel Response time tomodelMPa be handled to the surface, N to the surface, N 50 -kPa with Pi12-2, sBX75P 0.314 Corrugated 95 53 **BX75P 0.314 Dry steel 153 95 0.115BX110P 0.314 Corrugated 153 104 **BX110P 0.314 Dry steel 402 199 0.372** Response time varies based on quality and porosity of handled material.Material definitions:Corrugated card board = B-flute 3 mm, 80 Gurley seconds.Dry steel = cleaned rolled sheet metal.TECHNICAL DATA VACUUM CARTRIDGEPump Feed pressure Max. vacuum Air consumption Noise level Compressor power –modelcontinuous operationMPa-kPaNl/sdBAWPi12-2 0.314 90 0.47 65–74 155Pi12-2 0.6 83 0.79 77–82 260440 Specifications subject to change without notice.


VACUUM GRIPPERS PALLETISINGORDERING INFORMATIONDescriptionArt. No.AVP BX75P 2 Rail, Adjustable Vacuum Palletiser 0111103AVP BX75P 4 Rail, Adjustable Vacuum Palletiser 0111104AVP BX75P 6 Rail, Adjustable Vacuum Palletiser 0111105AVP BX110P 2 Rail, Adjustable Vacuum Palletiser 0111106AVP BX110P 4 Rail, Adjustable Vacuum Palletiser 0111107AVP BX110P 6 Rail, Adjustable Vacuum Palletiser 0111108Vacuum grippersPalletisingA: Side plateB: Aluminium extrusion profileSpecifications subject to change without notice. 441


VACUUM GRIPPERS PALLETISINGAVR – ADJUSTABLE VACUUM RAIL Lightweight design Simple X/Y axis adjustability Flexible modular design Energy saving from COAX®vacuum technologyTECHNICAL DATADescription Unit ValueWeight, AVR BX75P kg 2.1Weight, AVR BX110P kg 2.6Temperature range °C 10–50MaterialAL,PUR,POM,SS,Fe,CuZn,PP,NBRT-slot opening dimension mm 10LIFTING FORCES PER CUPSuction cup Material to Lifting forces vertical to the surface, N,Lifting forces parallel to the surface, N,modelbe handledat vacuum levelat vacuum level20 -kPa 60 -kPa 90 -kPa 20 -kPa 60 -kPa 90 -kPaBX75P Corrugated 39 114 — 36 57 —BX75P Dry steel 38 103 153 39 70 95BX110P Corrugated 93 173* — 68 139* —BX110P Dry steel 143 337 402 78 177 199* Lifting forces at maximum vacuum level 56 -kPaLIFTING FORCES & RESPONSE TIME PER CUPSuction cup Feed pressure Material to Lifting forces vertical Lifting forces parallel Response time tomodelMPa be handled to the surface, N to the surface, N 50 -kPa with Pi12-2, sBX75P 0.314 Corrugated 95 53 **BX75P 0.314 Dry steel 153 95 0.115BX110P 0.314 Corrugated 153 104 **BX110P 0.314 Dry steel 402 199 0.372** Response time varies based on quality and porosity of handled material.Material definitions:Corrugated card board = B-flute 3 mm, 80 Gurley seconds.Dry steel = cleaned rolled sheet metal.TECHNICAL DATA VACUUM CARTRIDGEPump Feed pressure Max. vacuum Air consumption Noise level Compressor power –modelcontinuous operationMPa-kPaNl/sdBAWPi12-2 0.314 90 0.47 65–74 155Pi12-2 0.6 83 0.79 77–82 260442 Specifications subject to change without notice.


VACUUM GRIPPERS PALLETISINGORDERING INFORMATIONDescriptionArt. No.AVR BX75P, Adjustable Vacuum Rail 0110053AVR BX110P, Adjustable Vacuum Rail 0110054Vacuum grippersPalletisingORDERING INFORMATION ACCESSORIESDescription: support frame, aluminium extrusion & side plateArt. No.Profile 45x90L 400 4xM12, AVP BX75P-BX110P 0111316Profile 45x90L 800 4xM12, AVP BX75P-BX110P 0111317Profile 45x90L 1200 4xM12, AVP BX75P-BX110P 0111318Side plate, AVP BX75P-BX110P 0111226See drawing AVP, Adjustable Vacuum Palletizer for support frame dimensions.Specifications subject to change without notice. 443


AccessoriesYOUR BEST SOLUTION – WITHOUT QUESTIONOur line of monitoring and control units for vacuum systems is unmatched when it comes to reliability. We focuson the overall solution, down to the last detail. We are fully aware that top quality components are as essentialas designing pumps and suction cups that are in a class apart. You will find everything you need to monitor andcontrol vacuum systems here.Reliability, economy and accurate control/monitoring are the common denominators.ACCESSORIESVacuum switches, inductive universal ..................... 446Vacuum switches, electro-mechanical ..................... 448Vacuum switches, pneumatic ................................. 450Mini vacuum switch, pre-set ................................... 452Vacuum switch, adjustable with knob ...................... 453Vacuum switch, adjustable with analogue output ..... 454Vacuum switch, adjustable with LED-display ............ 455Vacuum switch, adjustable with 1 output ................. 456Vacuum switch, adjustable ..................................... 457Vactrap .............................................................. 458Vactrap COAX® .................................................. 460Vacustat, 2/2 NO .................................................. 462Electrically controlled 2/2 valves DIP 55 ................ 464Solenoid valve DS 23 for control on/off ................... 466Vacuum filters ....................................................... 468Silencers .............................................................. 470Silencer COAX® ..................................................... 472Vacuum gauge and manometers ............................. 473Connection kits ..................................................... 474Accessories445


ACCESSORIESVACUUM SWITCHES, INDUCTIVE UNIVERSALThe adjustable vacuum switches are actuated at aset vacuum level and set by a knob.The pre-set vacuum switches are actuated at a presetvacuum level, non-adjustable. Converts a vacuum signal to an electric signal. Vacuum-actuated membrane linked to aproximity-inductive universal switch. The output functions PNP NO, PNP NC, NPN NOand NPN NC are available in the vacuum switch. The switch must be connected in series with theload.TECHNICAL DATADescription Unit ValueMaterialPBTP, PVC, PA SS NBR, POM Al, CuZnTemperature range °C -25–80Weight g 50–65Connection VacuumM5Hysteresis kPa 2Cable2 x 0.14 mm 2 x 2mSupply voltage V DC 24 (5–36)Safety classificationIP67Current Output, max mA 200Voltage drop, max V 4.6TECHNICAL DATA, SPECIFICDescription Unit Value3116064 3116089 3116090 3116091Signal range -kPa 10–95 10±1 30±3 70±5Supplement 1PNP NO = Normally Open, Positive logic. As the switch is activated, the gate at the feed current (+) closes andcontact is established.PNP NC = Normally Closed, Positive logic. As the switch is activated, the gate at the feed current (+) opens andcontact is interrupted.NPN NO = Normally Open, Negative logic. As the switch is activated, the gate at ground (-) closes and contactis established.NPN NC = Normally Closed, Negative logic. As the switch is activated, the gate at ground (-) opens and contactis interrupted.Note:NO, Normally Open, in electrical circuits corresponds to an open circuit breaker, which means that, if the gateis open, no current can pass through.NO, Normally Open, in pneumatic circuits corresponds to an open valve, which means that, if the valve is open,compressed air passes through.Supplement 2The adjustable vacuum switch, inductive universal, must be connected in series with the load!446 Specifications subject to change without notice.


ACCESSORIESORDERING INFORMATIONDescriptionArt. No.A Vacuum switch, inductive universal, adjustable with knob 3116064B Vacuum switch, inductive universal, pre-set (Signal range 10 -kPa) 3116089B Vacuum switch, inductive universal, pre-set (Signal range 30 -kPa) 3116090B Vacuum switch, inductive universal, pre-set (Signal range 70 -kPa) 3116091ABORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Connection set for vacuum switch 0100488Contents: Barrel nipple G1/8” M5 long, hose connector 4/2 M5. Material: Nickel-plated brass, SS, PA66, NBR, PA6. Fits: All pre-set andadjustable vacuum switches.AccessoriesSpecifications subject to change without notice. 447


ACCESSORIESVACUUM SWITCHES, ELECTRO-MECHANICALThe adjustable vacuum switches are actuated at aset vacuum level and set by a knob.The pre-set vacuum switches are actuated at a presetvacuum level, non-adjustable. Converts a vacuum signal to an electric signal. Vacuum-actuated membrane linked to an electromechanicalswitch. Output function NO or NC.TECHNICAL DATADescription Unit ValueMaterialPBTP, PVC, PA, SS, NBR, POM, Al, CuZnTemperature range °C -20–80Weight g 50–62Connection vacuumM5Function outputNO/NCHysteresis kPa 10Cable3 x 0.75 mm 2 x 0.5 mVoltage supply, max. V AC 250Safety classificationIP67Current output, max A 5TECHNICAL DATA, SPECIFICDescription Unit Value3116068 3116061 3116095 3116096Signal range -kPa 15–95 15–95 25±5 65±10Note:NO, Normally Open, in electrical circuits corresponds to an open circuit breaker, which means that, if the gateis open, no current can pass through.NO, Normally Open,in pneumatic circuits corresponds to an open valve, which means that, if the valve is open,compressed air passes through.448 Specifications subject to change without notice.


ACCESSORIESORDERING INFORMATIONDescriptionArt. No.A Vacuum switch, electro-mechanical, adjustable with knob 3116068B Vacuum switch, electro-mechanical, adjustable with screw 3116061C Vacuum switch, electro-mechanical, pre-set (Signal range 25 -kPa) 3116095C Vacuum switch, electro-mechanical, pre-set (Signal range 65 -kPa) 3116096ABORDERING INFORMATION, ACCESSORIESCDescriptionArt. No.Connection set for vacuum switch 0100488Contents: Barrel nipple G1/8” M5 long, hose connector 4/2 M5. Material: Nickel-plated brass, SS, PA66, NBR, PA6. Fits: All pre-set andadjustable vacuum switches.AccessoriesSpecifications subject to change without notice. 449


ACCESSORIESVACUUM SWITCHES, PNEUMATICThe adjustable vacuum switches are actuated at aset vacuum level and set by a knob.The pre-set vacuum switches are actuated at a presetvacuum level, non-adjustable. Converts a vacuum signal to a pneumatic signal. Vacuum-actuated membrane linked to apneumatic switch. Output function NO or NC.TECHNICAL DATADescription Unit ValuePressure range MPa 0.15–0.8MaterialPA, SS, NBR, POM, Al, CuZnTemperature range °C -10–60Weight g 39Connection vacuumM5TECHNICAL DATA, SPECIFICDescription Unit Value3116069 3116062 3116070 3116063 3116083 3116084 3116085 3116087 3116088Signal range -kPa 10–95 15–95 10±2 25±4 65±8 30±5 70±10Function output NO NC NO NCHysteresis kPa 3 12 3 12NO, Normally Open, in pneumatic circuits corresponds to an open valve, which means that, if the valve is open,compressed air passes through.450 Specifications subject to change without notice.


ACCESSORIESORDERING INFORMATIONDescriptionArt. No.A Vacuum switch, pneumatic, adjustable with screw (NO) 3116062A Vacuum switch, pneumatic, adjustable with screw (NC) 3116063B Vacuum switch, pneumatic, adjustable with knob (NO) 3116069B Vacuum switch, pneumatic, adjustable with knob (NC) 3116070C Vacuum switch, pneumatic, preset (NO 10 -kPa) 3116083C Vacuum switch, pneumatic, preset (NO 25 -kPa) 3116084C Vacuum switch, pneumatic, preset (NO 65 -kPa) 3116085C Vacuum switch, pneumatic, preset (NC 30 -kPa) 3116087C Vacuum switch, pneumatic, preset (NC 70 -kPa) 3116088ABCORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Connection set for vacuum switch 0100488Contents: Barrel nipple G1/8” M5 long, hose connector 4/2 M5. Material: Nickel-plated brass, SS, PA66, NBR, PA6. Fits: All pre-set andadjustable vacuum switches.AccessoriesSpecifications subject to change without notice. 451


ACCESSORIESMINI VACUUM SWITCH, PRE-SET Electronic vacuum switch with digital output Very low weight and small format Preferably installed near the suction cup PNP NO/NC or NPN NO/NC output depending ontype of connection Preset switching points at 30, 50 or 70 –kPa Vacuum connection with push-in connector withD=6 or G1/8” male thread Built-in red LED that indicates status M8 3-pin electric connection plugTECHNICAL DATADescription Unit ValueMaterialPA, TPU, SS, CuZn(Au)Temperature range ºC -25 – +85Weight g 5Signal range -kPa 30, 50 or 70 +5/-3FunctionPNP NO/NC, NPN NO/NCHysteresis kPa 6 ± 1Voltage V DC 24 (12-30)Safety classificationIP65Current max mA 100 inductive/400 resistiveVoltage drop, max (100mA/24V inductive load) V 0.055Response time ms 4DisplayRed LEDElectric connectionM8 3-pin maleORDERING INFORMATIONDescriptionArt. No.A Vacuum switch VS4015, 30 -kPa 0110245A Vacuum switch VS4015, 50 -kPa 0110246A Vacuum switch VS4015, 70 -kPa 0110247B Vacuum switch VS4016, 30 -kPa 0110248B Vacuum switch VS4016, 50 -kPa 0110249B Vacuum switch VS4016, 70 -kPa 0110250ABORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Cable M8 3-pin female L=2m 0108141452 Specifications subject to change without notice.


ACCESSORIESVACUUM SWITCH, ADJUSTABLE WITH KNOB The adjustable vacuum switch is actuated at aset vacuum level and set by a knob. Converts a vacuum signal to an electric signal. Vacuum-actuated membrane linked to aproximity-inductive universal switch. The output functions PNP NO, PNP NC, NPN NOand NPN NC are available in the vacuum switch. The switch must be connected in series with theload. Fits vacuum pump P3010.TECHNICAL DATADescription Unit ValueMaterialPA, SS, NBR, POM, Al, PBTP, PVC, CuZnTemperature range ºC -25–80Signal range -kPa 10–95Hysteresis kPa 2Weight g 71Connection vacuumD=6/M5FunctionNO/NC/PNP/NPNCable2 x 0.14 mm 2 x 2mVoltage supply V 24 (4–36)Safety classificationIP67Current output, max mA 200Voltage drop, max V 4.6ORDERING INFORMATIONDescriptionArt. No.Vacuum switch, adjustable with knob 0104350AccessoriesSpecifications subject to change without notice. 453


ACCESSORIESVACUUM SWITCH, ADJUSTABLE WITH ANALOGUE OUTPUT 1 output NO and 1 analogue output 2 m cable included, female connector Fits vacuum pump P3010TECHNICAL DATADescription Unit ValueFeed pressure, max MPa 0.2MaterialPC, POM, NBR, SSTemperature range ºC -20–70Weight g 50Connection vacuumD=6/M5FunctionNO, NPN/PNPHysteresis % 1–15Supply voltage V DC 10.8–30Voltage output V DC 1–5Safety classificationIP40Current output, max. (load resistance min. 5kΩ) mA 1Humidity % RH 35–85Response time ms ˜1Accuracy at 25°C±3% F.S.Current consumption, max mA 17High-voltage resistant V AC 500Insulation at 500 VDC MO 100Vibration resistance, 1,5 mm, XYZ, 2 h Hz 10–500Electric connectionM8 4 pin maleNon-lubricated air, non-corrosive gases, compatible with Polycarbonate and Polyacetal.ORDERING INFORMATIONDescriptionArt. No.Vacuum switch, adjustable, PNP NO MM8 0107729Vacuum switch, adjustable, NPN NO MM8 01077302x3.626.5514. 60454 Specifications subject to change without notice.


ACCESSORIESVACUUM SWITCH, ADJUSTABLE WITH LED-DISPLAY 2 outputs, NO M8 4-pin male connector LED - displayTECHNICAL DATADescription Unit ValueFeed pressure, max MPa 0.2MaterialPC, POM, NBR, AlTemperature range ºC -10–60Weight g 52Connection vacuumD=6/M5FunctionNO, NPN/PNPHysteresis kPa 2Voltage supply V DC 12–24Voltage output V DC 1–5Dielectric strength, 1 min V AC 500Safety classificationIP40Current output max. (load resistance min. 5kΩ) mA 1Humidity %RH 35–85Response time ms 2Accuracy at 25°C±3% F.SCurrent consumption, maximum mA 35Insulation resistance, at 500 VDC MO/MW 100Display2-digits LEDNon-lubricated air, non-corrosive gases, compatible with Polycarbonate and Polyacetal.ORDERING INFORMATIONDescriptionArt. No.Vacuum switch, adjustable, PNP NO DM8 0107732Vacuum switch, adjustable, NPN NO DM8 0107733AccessoriesSpecifications subject to change without notice. 455


ACCESSORIESVACUUM SWITCH, ADJUSTABLE WITH 1 OUTPUT 1 output NO M8 3-pin male connector 2m cable included, female connectorTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.2Vacuum range -kPa 0–100MaterialPC, AlTemperature range °C -10–60Weight g 6Connection vacuumD=6/M5Hysteresis±2% F.S.Voltage supply V DC 10.8–30Safety classificationIP40Humidity %RH 35–85Response time, approx. ms 1Accuracy, at 25°C±3% F.S.Current consumption, max mA 20High-voltage resistance V DC 500Insulation at 500 VDC MO 100Vibration resistance, 1.5 mm, XYZ, 2 h Hz 10–55Non-lubricated air, non-corrosive gases, compatible with Polycarbonate and Polyacetal.ORDERING INFORMATIONDescriptionArt. No.Vacuum switch, adjustable, PNP NO LM8 0107731456 Specifications subject to change without notice.


ACCESSORIESVACUUM SWITCH, ADJUSTABLE 1 output NO Cable 1.5 mTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.6Vacuum range -kPa 0–100MaterialPC, SS, PSC,CuZn, PATemperature range °C -10–60Weight g 6Connection vacuumM5Hysteresis±2% F.S.Voltage supply V DC 10.8–30Safety classificationIP40Humidity %RH 35–85Response time, approx. ms 1Accuracy, at 25°C±3% F.S.Current consumption, max mA 20High-voltage resistance V DC 500Insulation at 500 VDC MO 100Vibration resistance, 1.5 mm, XYZ, 2 h Hz 10–55DisplayLEDORDERING INFORMATIONDescriptionArt. No.Vacuum switch PNP M5 0110358Vacuum switch NPN M5 0110359AccessoriesSpecifications subject to change without notice. 457


ACCESSORIESVACTRAP Check valve that "traps" the vacuum pressure invacuum systems for an indefinite period of timein sealed applications, such as when handlingsheet metal or glass with suction cups. The object can be handled with an extremely highdegree of safety even if the supply ofcompressed air should be cut off, if a pumpfailure should occur or if the emergencystop should be activated, thus preventing theobject from being dropped. Equipped with a built-in blow-off valve toprovide quick release of the object. Available in a special version in which thevacuum pump and blow-off connections areinterconnected (x-drilled), making it suitable forejectors with integrated blow-off valve, such asPIAB’s AVM models.TECHNICAL DATADescription Unit ValueFeed pressure, max., blow-off MPa 0.7Feed pressure, min., breakaway blow-off MPa 0.25MaterialAL, Steel, CeramicTECHNICAL DATA, SPECIFICDescription Unit Value0109233 0111167 0110454 0109234 0110455 0111154 0109235Temperature range °C -28–65 -10–150 -28–65 -28–65 -28–65 -28–65 -28–65Weight g 235 235 235 230 233 230 110Extra — — — VacuumdetectionG1/8"fem.x-drilledvacuum/blow-offx-drilledvacuum/blow-offVacuum flow, max. Nl/s 0.7 0.7 0.7 0.7 0.7 0.7 0.5Sealing material NBR Viton® NBR—458 Specifications subject to change without notice.


ACCESSORIESORDERING INFORMATIONDescriptionArt. No.A Vactrap® VT-1A 0109233A Vactrap® VT-1A, Viton® sealing 0111167B Vactrap® VT-1A, extra mounting 0110454C Vactrap® VT-1A, extra vacuum port 1/8" 0109234A Vactrap® VT-1AGM, x-drilled vacuum/blow-off 0110455B Vactrap® VT-1AMGM, x-drilled vacuum/blow-off, extra mounting 0111154D Vactrap® VT-2A 0109235aP-bP-25.12.CU639. 56.9.6G3 "4x /42x -2 /812. 25.6. 38.VAC50.25.6.2x 327625.6.12.2A. a = Vactrap, b = Vactrap x-drilled B. a = Vactrap, b = Vactrap x-drilledCU11. 277 48 2G1 "4 1.45VAC8/82010G1 "1 .74x /869. 56.CU25.12.#10 411. 27/812. 25.G1 "2x 576C6. 38.25BOC50.1956 9D524 4VA1AccessoriesSpecifications subject to change without notice. 459


ACCESSORIESVACTRAP COAX® "COAX® patented technology” means fasterresponse and lower energy consumption. Reliable even at low operating feed pressure. Check valve that "traps" the vacuum pressure invacuum systems for an indefinite period of timein sealed applications, such as when handlingsheet metal or glass with suction cups. The object can be handled with an extremely highdegree of safety even if the supply ofcompressed air should be cut off, if a pumpfailure should occur or if the emergency stopshould be activated, thus preventing the objectfrom being dropped. Equipped with a built-in blow-off valve toprovide quick release of the objectTECHNICAL DATADescription Unit ValueFeed pressure, max. MPa 0.7Feed pressure, min., breakaway blow-off MPa 0.25Feed pressure, optimum COAX® MPa 0.314Air consumption, 0.314 MPa Nl/s 0.47Vacuum, 0.314 MPa -kPa 90Noise level, with load dBA 65Noise level, without load dBA 74MaterialPA, AL, Steel, Ceramic, NBRTemperature range °C -10–50Vacuum flow, max. Nl/s 0.68TECHNICAL DATA, SPECIFICDescription Unit Value0110456 0110435 0111147Weight g 295 389 420Connection, mounting — Ball joint Lock pin 19 mmVACUUM FLOWFeed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.314 0.47 0.68 0.6 0.44 0.27 0.19 0.14 0.1 0.06 0.03 — 90EVACUATION TIMEFeed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.314 0.47 0.17 0.32 0.58 1.1 1.8 2.7 4 6.4 — 90460 Specifications subject to change without notice.


ACCESSORIESORDERING INFORMATIONDescriptionArt. No.A Vactrap® VT1-AS COAX® Pi12-2 0110456B Vactrap® VT1-AS COAX® Pi12-2, ball joint 0110435C Vactrap® VT1-AS COAX® Pi12-2, lock pin 19 mm 011114726 3/8G1 "54.46.2G3 " G1 "63.4P474 17 42x 54 4BOAI8P412. 917 4BO5AIAB44.62.5.4G1 "76CAccessories19/8BO12.25.91.7 45AISpecifications subject to change without notice. 461


ACCESSORIESVACUSTAT, 2/2 NO The Vacustat is a vacuum-controlled 2/2 NOvalve with adjustable vacuum level for switching. The Vacustat comes in two variations: Vacustat 1with small hysteresis and Vacustat 2 with largehysteresis. Minimises consumption of compressed air bycontrolling the incoming air flow to a vacuumpump. The vacuum pump must be fitted with a nonreturnvalve. The Vacustat is recommended for vacuum pumpsin sealed systems. Fits PIAB vacuum pump size 5–120.TECHNICAL DATADescription Unit ValueFeed pressure MPa 0.4–0.7MaterialPA, Al, SS, NBR, PUR, TPU, POM, CuZnTemperature range °C 0–60Weight g 90Connection vacuum2 x M5Connection compressed air2 x 1/8" NPSFSignal range -kPa 15–99Function2/2 NOHysteresis kPa 2/8Flow, nominal Nl/s 8.6kv 7.8Life span, mechanical cycles >10,000,000Diameter, nominal mm 3.7FunctionA vacuum-controlled valve shuts off the flow of compressed airto the pump when the pre-set vacuum level is reached (1). Thevacuum level is set by a knob. Because of minor leakage in avacuum system the vacuum level drops, and after a while thestart-up level of the valve is reached (2). Then the pump will startand work until the shut-off level is reached again (3), etc.ConnectionA = Vacuum pump with non-return valveB = Vacuum switchC = Feed valveD = Suction cupE = Vacuum filter462 Specifications subject to change without notice.


ACCESSORIESORDERING INFORMATIONDescriptionArt. No.Vacustat 1 with small hysteresis 0101074Vacustat 2 with large hysteresis 0101075P-21830316.42x NPSF 1/8"15.5 29.2M544ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Connection kit for Vacustat 0100750AccessoriesM589236Specifications subject to change without notice. 463


ACCESSORIESELECTRICALLY CONTROLLED 2/2 VALVES DIP 55 On/off valve 1/8" NPSF ports 0.6 W solenoid Electrical connections: plug-in contacts and DIN(c) Suitable for PIAB vacuum pumps up to Classicsize. Manual overrideTECHNICAL DATADescription Unit ValueFeed pressure, range MPa 0.4–0.7 MPaMaterialPPS, PA, TPU, Al, NBR, CuZn, PURTemperature range ºC 0–60Weight g 102Connection compressed air 2 x NPSF 1/8"FunctionNCSupply voltage V DC 24DisplayLEDFlow, nominal Nl/s 8.6Kv 7.8Lifespan, mechanical cycles 10,000,000Power W 0.6Ratings % 100Bore-through diameter, nominal mm 3.7Electrical connections are included.Compressed air, filtration 40μm, non-lubricated.TECHNICAL DATA, SPECIFICDescriptionValue0101016DIP 55 NC 2406SE0101071DIP55 NC 2406 SD0101017DIP 55 NO 2406 SEElectrical connection Plug-in connection * DIN (c) * Plug-in connection * DIN (c) *Safety specification — IP65 — IP65*) Electrical connections are included. * Electrical connections are to be ordered separately.0101072DIP 55 NO 2406 SD464 Specifications subject to change without notice.


ACCESSORIESORDERING INFORMATIONDescriptionArt. No.A Electrically controlled 2/2 valve DIP55 NC 2406 SE 0101016A Electrically controlled 2/2 valve DIP55 NO 2406 SE 0101017B Electrically controlled 2/2 valve DIP55 NC 2406 SD 0101071B Electrically controlled 2/2 valve DIP55 NO 2406 SD 0101072ABAccessoriesSpecifications subject to change without notice. 465


ACCESSORIESSOLENOID VALVE DS 23 FOR CONTROL ON/OFF 3/2 Valve Body with 3 M5 ports, port 1 and 2 in-line Nominal diameter of 2.3 mm Suitable for compressed air, filtration 40μ 2.5 W solenoid Manual overrideTECHNICAL DATADescription Unit ValueFeed pressure, maximum MPa 0.7Feed pressure MPa -0.2–0.6MaterialNi, Al, SS, POM, CuZn, NBRWorking temperature °C -18–50Weight g 100Connection compressed air D=6Connection exhaust D=6Supply voltage V DC 24Safety classification, DIN (c) socketIP65DisplayLEDFlow, nominal Nl/s 1.3kv 1.2Frequency Hz >160Lifespan, mechanical cycles 100,000,000Power consumption W 2.5Ratings % 100Electrical connectionDIN (c) socketORDERING INFORMATIONDescriptionArt. No.Solenoid valve DS 23 for control ON/OFF 0104274466 Specifications subject to change without notice.


ACCESSORIESAccessoriesSpecifications subject to change without notice. 467


ACCESSORIESVACUUM FILTERS To filter dust and other small particles from thevacuum flow. Reduces the risk of operation breakdown orstoppage in the pump. Replaceable filter element.TECHNICAL DATADescription Unit ValuePressure range MPa -0.1–0 MPaMaterialPA, PC, PETemperature range ºC -20–100Removal efficiency μm 10TECHNICAL DATA, SPECIFICDescription Unit Value3116671 3116652 3116672 3116653Weight g 70 170 424 550Flow nominal Nl/s 2.5 15 42 85Volume Internal cm 3 45 205 495 675Filter area m 2 0.003 0.010 0.019 0.023468 Specifications subject to change without notice.


ACCESSORIESORDERING INFORMATIONDescriptionArt. No.A Vacuum filter G3/8" 3116671B Vacuum filter G3/4" 3116652C Vacuum filter G1" 3116672D Vacuum filter G1½" 31166532x G3/8"G1/8"762x G3/4"G1/8"91138.571.318.514A B CG1/8"126209.5312x G1 1/2"DTECHNICAL DATA, ACCESSORIESDescription Unit Value3116673 3116674 3116675 3116676 3116223 3116224Weight g 7 26 50 74 80 144Filter area m 2 0.003 0.0103 0.019 0.023 0.028 0.074Removal efficiency μm 10 10 10 10 5 5ORDERING INFORMATION, ACCESSORIESDescriptionArt. No.Filter element 3/8" 3116673Filter element 3/4" 3116674Filter element 1" 3116675Filter element 1½" 3116676Filter element 3/4" (special) 3116223Filter element 1½" (special) 3116224AccessoriesSpecifications subject to change without notice. 469


ACCESSORIESSILENCERS Reduce noise from exhaust Flow-through designTECHNICAL DATADescription Unit ValueNoise level reduction, approximately dB(A) -10MaterialPA, HDPETemperature range ºC -20–100TECHNICAL DATA, SPECIFICDescription Unit Value3116009 3116002 0112499/0113003 0103224Weight g 14 61 95.1 425470 Specifications subject to change without notice.


ACCESSORIESORDERING INFORMATIONDescriptionArt. No.A Silencer G3/8" 3216009B Silencer G3/4" 3216002C Silencer G1" 0112499C Silencer 1" NPSF 0113003D Silencer G1½" 01032242440G3/4"A B CDAccessories271./83/ N2.59.5125.585249205G1 1/2"Specifications subject to change without notice. 471


ACCESSORIESSILENCER COAX® Reduces noise from the exhaust Compatible with aluminium holders for MINI andMIDI COAX® cartridges Simple snap locking when mounting Through-flow design that eliminates the risk ofimpaired performance due to clogging of thesilencerTECHNICAL DATADescription Unit ValueMaterialPA, TPU, PETemperature range °C -20–80Noice level reduction dB(A) ≥10TECHNICAL DATA, SPECIFICDescription Unit Value0111977 0111976Weight g 8.64 36.56ORDERING INFORMATIONDescriptionArt. No.A Silencer MINI COAX® 0111977B Silencer MIDI COAX® 0111976OOOO87AB472 Specifications subject to change without notice.


ACCESSORIESVACUUM GAUGE AND MANOMETERS Analogue indicator, springjoint – lever system The instruments include nut for installation on apanelTECHNICAL DATADescription Unit ValueAccuracy, of full scale % 2.5MaterialCuZn, ABS, PMMATECHNICAL DATA, SPECIFICDescription Unit Value3101602 3101603 3101626Weight g 90 55 50Signal range MPa 0–0.1 0–1 0–0.25Medium Vacuum Over pressureORDERING INFORMATIONDescriptionArt. No.B Vacuum gauge 100 -kPa 3101602A Manometer 1 MPa 3101603A Manometer 250 -kPa 3101626AccessoriesSpecifications subject to change without notice. 473


ACCESSORIESCONNECTION KITS Push-in connectors with hose dimensionscompatible with the pump connections. Corrosion-resistant material. Complete kit for one pump.TECHNICAL DATADescription Unit ValueTemperature range ºC -25–75MaterialPOM, NBR, SS, CuZn, AlTECHNICAL DATA, SPECIFICDescription 0104901 0104902 3207005 0104903 3207010 3401008Connection kit for vacuum pump MINI 5 MINI 10 MINI 5 MINI 5-20 CLASSIC 25-120 MAXI*Connection plate A A B B, C D AllHose dimension ** for compressed air d=2 mm d=4 mm D=4 mm D=6 mm D=8 mm D=6 or 4 mmHose dimension ** for vacuum D=4 or 6 mm D=6 or 8 mm D=8 mm D=10 mm d=12, 19, 25 mm —* Remote control, ** d = inner diameter, D = outer diameterORDERING INFORMATIONDescriptionArt. No.Connection kit for pump MINI 5, connection plate A 0104901Connection kit for pump MINI 10, connection plate A 0104902Connection kit for pump MINI 5, connection plate B 3207005Connection kit for pump MINI 5-20, connection plate C and pump MINI 10-20, connection plate B 0104903Connection kit for pump CLASSIC 25-120, connection plate D 3207010Connection kit for pump MAXI*, all connection plates 3401008474 Specifications subject to change without notice.


ACCESSORIESAccessoriesSpecifications subject to change without notice. 475


PRODUCT INDEXVACUUM PUMPSCLASSICH40 ......................................................................122H120 ....................................................................124L25 .......................................................................110L50 .......................................................................112L100 .....................................................................114M25L ....................................................................116M50L ....................................................................118M100L ..................................................................120Mounting brackets .................................................157CLASSIC MPH240 ....................................................................142H480 ....................................................................144L150 .....................................................................126L200 .....................................................................128L300 .....................................................................130L400 .....................................................................132M150L ..................................................................134M200L ..................................................................136M300L ..................................................................138M400L ..................................................................140Mounting brackets .................................................157MAXICentral exhaust ......................................................155Connection flange ..................................................154MLL200 ................................................................146MLL400 ................................................................148MLL800 ................................................................150MLL1200 ..............................................................152Non-return valve .....................................................156MINIL7 ...........................................................................86L14 .........................................................................88L28 .........................................................................90L56 .........................................................................92M5L ........................................................................94M10L ......................................................................96M20L ......................................................................98M40L ....................................................................100X5L .......................................................................102X10L .....................................................................104X20L .....................................................................106X40L .....................................................................108P2010Blow-Off P2010 ....................................................... 36P2010 Bi03-2 ......................................................... 30P2010 Bi03-2 with DIN-rail ....................................... 32Quick-Release P2010 ............................................. 34P3010P3010 AVM Pi12-3 ............................................... 58P3010 AVM Pi12-3 x 2 .......................................... 60P3010 common-feed adapters .................................. 56P3010 connection modules ...................................... 54P3010 exhaust adapter ........................................... 57P3010 mounting rail ................................................ 55P3010 quick-release modules .................................. 52P3010 pump modules ............................................. 50P3010 with connections 3 x 1/8" NPSF .................... 38P3010 with connections 6 x 1/8" NPSF .................... 40P3010 with energy-saving system ............................. 48P3010 with quick-release and tank 30 cm 3 ................ 44P3010 with quick-release and tank 60 cm 3 ................ 46P3010 with quick-release including tank 3 cm 3 .......... 42P6010P6010 AVM .......................................................... 80P6010 Classic ........................................................ 84P6010 Pi48-3X2 ...................................................... 66P6010 Pi48-3x4 ...................................................... 70P6010 Si32-3x1 ...................................................... 72P6010 Si32-3x3 ...................................................... 76P6010 Si32-3x4 ...................................................... 78P6010 PCC ............................................................. 82P6010 Pi48-3X1 ...................................................... 64P6010 Pi48-3x3 ...................................................... 68P6010 Si32-3x2 ...................................................... 74PMAT COAX® .......................................................... 62476


PRODUCT INDEXSUCTION CUPSB5 ........................................................................172B8 ........................................................................174B10-2 ....................................................................176B15-2 ....................................................................178B20 ......................................................................180B30-2 ....................................................................182B40 ......................................................................184B50 ......................................................................186B50-2 ....................................................................188B75 ......................................................................190B75-2 ....................................................................192B110 ....................................................................194B110-2 ..................................................................196B150 ....................................................................198B75P .....................................................................200B15MF ..................................................................202B20MF ..................................................................204B30MF ..................................................................206B40MF ..................................................................208B50MF ..................................................................210BF80P ...................................................................212BF110P .................................................................214BL20-2 ..................................................................216BL30-2 ..................................................................218BL40-2 ..................................................................220B-BL40-2 ...............................................................222BL50-2 ..................................................................224BL40-3P .................................................................226BX25P ...................................................................228BX35P ...................................................................230BX52P ...................................................................232BX75P ...................................................................234BX110P .................................................................236D15-2 ....................................................................238D20-2 ....................................................................240D30-2 ....................................................................242D50 ......................................................................244F15 .......................................................................246F20 .......................................................................248F25 .......................................................................250F30-2 ....................................................................252F40-2 ....................................................................254F50-2 ....................................................................256F75 .......................................................................258F110 .....................................................................260F150 .....................................................................262F15MF ...................................................................264F20MF ...................................................................266F25MF ...................................................................268F30MF ...................................................................270F40MF ...................................................................272F50MF ...................................................................274F75P .....................................................................276F110P ...................................................................278FC20P ...................................................................280FC25P .................................................................. 282FC35P .................................................................. 284FC50P .................................................................. 286FC75P .................................................................. 288FC100P ................................................................ 290FC150P ................................................................ 292FP200 .................................................................. 294FP300 .................................................................. 296OB20x60P ............................................................ 298OB35x90P ............................................................ 300OB50x140P .......................................................... 302OB65x170P .......................................................... 304OBL40x90P ........................................................... 306OC60x140 ............................................................ 308OC35x90P ............................................................ 310OF10x30P ............................................................. 312OF15x45P ............................................................. 313OF25x70P ............................................................. 314OF40x110P ........................................................... 316OF55x150P ........................................................... 318OF70x175P ........................................................... 320OP20x100 ............................................................ 322OP40x200 ............................................................ 324P35 ...................................................................... 326P60 ...................................................................... 328P100 .................................................................... 330P200 .................................................................... 332P300 .................................................................... 334U2 ........................................................................ 336U3 ........................................................................ 337U4 ........................................................................ 338U6 ........................................................................ 340U8 ........................................................................ 342U10 ...................................................................... 344U15 ...................................................................... 346U20 ...................................................................... 348U30 ...................................................................... 350U40-2 ................................................................... 352U50-2 ................................................................... 354FITTINGSFitting M2.5 male .................................................. 356Fitting M5 male ..................................................... 357Fitting M5 male ..................................................... 358Fitting M5 female .................................................. 359Fitting G1/8" male ................................................ 360Fitting G1/8" male – M5 female ............................. 361Fitting G1/8" male – M5 female of composite ......... 362Fitting 1/8" NPSF female ....................................... 363Fitting 1/8" NPSF female ....................................... 364Fitting 1/8" NPSF female of composite ................... 365Fitting 1/8" NPSF female of composite ................... 366Fitting G1/4" male ................................................ 367Fitting G1/4" male ................................................ 368Index477


PRODUCT INDEXFitting G3/8" male .................................................369Fitting G3/8" male .................................................370Fitting G3/8" male .................................................371Fitting 3/8" NPT male .............................................372Fitting 5xM5 female ................................................373Fitting 5x1/8" NPSF female ....................................374Fitting 5x1/8" NPSF female ....................................375Fitting 75 ...............................................................376Fitting 110 .............................................................377Fitting 150 .............................................................378ACCESSORIESAngle adaptors ...................................................... 382Ball joints ............................................................. 381Level compensators ............................................... 379Level compensator LC30......................................... 380Spare parts ........................................................... 384T-slot adapters ...................................................... 383VACUUM GRIPPERSAtmospheric Quick-Release valve – AQR ...................436AVP – Adjustable Vacuum Palletiser .........................440AVR – Adjustable Vacuum Rail .................................442Check valve VGS3010 .........................................437VGS3010 B75P ...................................................394VGS3010 BF80P .................................................396VGS3010 BX35P .................................................398VGS3010 BX52P .................................................400VGS3010 BX52P with stabilizer ............................404VGS3010 BX75P .................................................402VGS3010 BX75P with stabilizer ............................406VGS3010 F110P .................................................416VGS3010 F75P ...................................................414VGS3010 FC100P .............................................. 412VGS3010 FC50P ................................................ 408VGS3010 FC75P ................................................ 410VGS3010 mounting-kits ...................................... 438VGS3010 OB35x90P .......................................... 418VGS3010 OB50x140P ........................................ 420VGS3010 OB65x170P ........................................ 422VGS3010 OBL40X90P ........................................ 424VGS3010 OF25x70P ........................................... 426VGS3010 OF40x110P ......................................... 428VGS3010 OF55x150P ......................................... 430VGS3010 OF70x175P ......................................... 432VGS3010–LC30 .................................................. 434ACCESSORIESConnection kits ......................................................474Electrically controlled 2/2 valves DIP 55 .................464Mini vacuum switch, pre-set ....................................452Silencer COAX® .....................................................472Silencers ...............................................................470Solenoid valve DS 23 for control on/off ...................466Vactrap ...............................................................458Vactrap COAX® ...................................................460Vacustat, 2/2 NO ...................................................462Vacuum filters ........................................................468Vacuum gauge and manometers ............................. 473Vacuum switch, adjustable ..................................... 457Vacuum switch, adjustable with 1 output ................. 456Vacuum switch, adjustable with analogue output ..... 454Vacuum switch, adjustable with knob ...................... 453Vacuum switch, adjustable with LED-display ............ 455Vacuum switches, electro-mechanical ..................... 448Vacuum switches, inductive universal ...................... 446Vacuum switches, pneumatic ................................. 450478

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!