15. Change the oscilloscope's sweep speed to 1 uSEC/DIV.16. Move the scope probe tip to TP7. Adjust the trigger LEVEL controlto get a clear display. The pulses at this point should have nodual images on the rising and falling edges (though a certainamount of jitter will be present).16. If necessary, adjust potentiometer R28 on the analog card untilthere is a single, stable image with a minimum of jitter.17. After you have made the adjustments, turn the <strong>Apple</strong> ][ off. Thendisconnect the customer's drive, apply Glyptol to thepotentiometers, and re-assemble the drive.This completes the Comparator Offset adjustment procedure.If you were unable to make the adjustments, replace the Analog boardand run the test again.<strong>Disk</strong> Drive Calibration rev. 09/10/82 page 3.23