13. After the test signal has been written to the diskette, a messagewill be displayed to tell you that you may proceed with the test.Adjust the oscilloscope's trigger LEVEL and INTENSITY controls fora stable display (though some jitter may be present near the rightend). The rising portion of the pulse should be 2. 5 - 3.0microseconds wide (5-6 divisions). The total pulse width will be3.75 - 4.0 microseconds (7.5 - 8 divisions).14. If necessary, adjust potentiometer R21 or R33 until the centralpeak is in the correct position.NOTE: On most Analog boards, R21 is a fixed resistor and R33 is theadjustment. On some, R21 is a potentiometer and should be used forthe adjustment. On other boards, neither potentiometer is present.In this last case, the board must be replaced if adjustment isindicated.CONTINUED ON NEXT PAGE<strong>Disk</strong> Drive Calibration rev. 09/10/82 page 3.22