Apple Disk II Technical Procedures
Apple Disk II Technical Procedures
Apple Disk II Technical Procedures
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
7. Connect the probe tip to TP5 and the ground lead to TP4 on theAnalog Card of the drive being tested.The Test:8. Boot the Calibration (or Alignment Aid) <strong>Disk</strong>ette in the known gooddrive, then remove the diskette.9. Put the scratch diskette in the drive being tested,10. After the main menu appears, slowly type ASAA to select drive 2 asthe target disk, then press .11. Slowly type SSA to select the Amplitude test.12. A warning will be displayed on the screen that the test will writeon any diskette in the target drive. Type A to proceed with thetest.CONTINUED ON NEXT PAGE<strong>Disk</strong> Drive Calibration rev. 09/10/82 page 3.21