The Test:12. Change the oscilloscope controls as follows:SECONDS(or TIME)/DIV = .5 MSEC/D1VVOLTS(or AMPLITUDE)/DIV - 50 MV/DIV (5 MV/DIV for 10X probe)Input (AC/DC/GND) = ACSweep Mode (AUTO/NORM) = NORM (the trace will disappear)13. Connect the probe tip to TP8.14. Put the Alignment diskette (090-0004) in the drive being tested.15. Slowly type SSSA34, then press to move the head to track34.CONTINUED ON NEXT PAGE<strong>Disk</strong> Drive Calibration rev. 09/10/82 page 3.9