12.07.2015 Views

Mitsubishi Graphic Operation Terminal GOT1000 ... - Omni Ray AG

Mitsubishi Graphic Operation Terminal GOT1000 ... - Omni Ray AG

Mitsubishi Graphic Operation Terminal GOT1000 ... - Omni Ray AG

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Q25HCPUCASE STUDY 2FA SolutionsObstacles are often encountered when using many different types of FA devices.The following problems can be resolved by linking with <strong>GOT1000</strong>.Enhancing sequence control.General-purpose PLCLINK1Powerful functionality that is useful during startup and the tuning process!Ideal for PLCs in the field and on the plant floor!Can PLC programs be monitored with the GOT?Ladder monitor function andladder editor functionSequence programs can be monitored in a circuit diagram (ladderformat).Can the root cause beeasily identified?One-touch ladder jump function(Q/L/QnA series ladder monitor and ladder editor function)For details,see P.44 P.45For details,see P.44By setting a program name and coil number of the PLC to a touchswitch, the relevant ladder circuit block can be displayed directly.Troubles can be handled smoothly from the alarm screen.SFC monitor functionThe Q series (Q mode) SFC programs (MELSAP3, MELSAP-L) can bemonitored in a SFC diagram format.Can simple changes toladder programs be madewithout a personal computer?Ladder editor functionSequence programs of the Q series (Q mode) and the L series can beedited in a circuit diagram (ladder format).Edit Find/Replace Touch the Convert area you Display wish Online to edit.The circuit input window is displayed.For details,see P.44For details,see P.45GOT SolutionsFA SolutionsCan the program be debuggedwithout opening the cabinet?FA transparent functionConnected with a personal computer, theGOT acts as a transparent gateway toenable programming, start up, andadjustment of equipment using GX Works2or GX LogViewer. Users do not have tobother with opening the cabinet or changingcable connections. (On the GT10 series,the FA transparent function can be used viathe interface on the rear side.)Can the PLC programsbe recovered after failure?For details,see P.39GX Works2GX LogViewer, etc.Can the PLC status orerrors be checked quickly?System monitor functionPLC devices can be monitored and changed.Intelligent module monitor functionBuffer memory values and I/O information can be monitoredand changed.Network monitor functionEnable monitoring of network line conditions on a dedicated screen.Network module status displayFor details,see P.46For details,see P.46For details,see P.46Enable monitoring of LED status, error status, among others ofnetwork modules on a GOT.One touch to jumpto Ladder Monitor or Ladder Editor ScreenUsing the MELSEC-L series orhigh-speed data logger module!Log viewer functionDisplay the ladder block ofthe coil set to the touch switchCan collected logging data bechecked at the worksite?PrintScreenPLC RD.ExitMon.MenuEnter ladder programCircuit symbol: Changing from normallyclosed contact to normally open contact.Device: Changing from M422 to M200.Enter ladder programInsert row Delete row Insert column Delete columnMonitoring batch control!Can Process and Batchmonitoring be simplified?Building a process controlsystem using <strong>GOT1000</strong>Insert row Delete row Insert column Delete columnFor details,Backup/restoration functionsee P.42For details,MELSEC-L troubleshooting functiion see P.46Logging data collectedSequence programs and parameters can be backed up to the CF cardusing the L series orPX Developer creates GOTA dedicated maintenanceor USB memory in the GOT. Users can then perform batch operation tohigh-speed data loggerprocess control screensscreen for the L series isrestore the data to the PLC.module can beautomatically.included. The CPU statusdisplayed on the GOT.The automatically generatedCF card,If data is backed up and error information canetc.data can be used for both thebe easily confirmed withoutGOT (worksite) anda personal computer.Replace CPUGT Soft<strong>GOT1000</strong> (monitorRestoreIf a problem occurs, youroom), and therefore monitorcan jump to a functionscreens can be createdscreen such as the ladderefficiently.monitor to quickly takeSequencecorrective actions.program,8 etc.9For details,see P.40For details,see P.26 P.51

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!