Mitsubishi Graphic Operation Terminal GOT1000 ... - Omni Ray AG

Mitsubishi Graphic Operation Terminal GOT1000 ... - Omni Ray AG

Mitsubishi Graphic Operation Terminal GOT1000 ... - Omni Ray AG

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

External dimensionsPanel cut dimensionsWhen the GOT is installedScreen size Type of GOT main unitGT169515"GT1595GT1685 ✽112.1"GT1585 ✽1GT167M ✽210.4"GT157M ✽2GT1275GT166M8.4"GT156MGT1265GT1655 ✽3GT155M ✽35.7"GT115M ✽3GT105M ✽34.7"GT104M4.5"GT10303.7"GT1020Product installation spacingA383.5302289227153130137105(Unit: mm)B282.52282001761211036666The GOT must have the clearances from other devices as shown in [Fig. A]. The GOT may require more distance than the dimensions shown in the tabledepending on the types of connection cables. Consider the connector dimensions and cable bending radius when designing the installation.EThickness:2 to 4mmOther deviceor control panelA +2 ✽40Panel openingWhen the CF card extension unit (mounting unit on control panel) is installedTypeABCautions when installing and uninstallingGT15-CFEX-C08SET 94.033.0When installing the CF card extension unit on the control panel, make sure that the extension unit does not interfere with the extension unitcable or the CF card interface of the GOT. Place the CF card extension unit at a distance of 25mm or more from the GOT.For installation locations, see the GT16 User's Manual (Hardware) or the GT15 User's Manual.For compatibility with GOT900 series, see ''Backward compatibility'' (page 81).GT16/GT15(Unit: mm)ItemGT1695 GT1685 GT167M GT166M GT1655 GT1595 GT1585 GT157M GT156M GT155MGOT only50 or more (20 or more) 61 or more50 or more (20 or more)50 or more (21 or more) 49 or moreWhen a bus connection unit is installed50 or more (20 or more) 50 or more (24 or more) 50 or more (33 or more) 50 or more (43 or more) 50 or more 50 or more (20 or more) 50 or more (35 or more) 50 or more (40 or more) 50 or moreWhen a serial communication unit is installed50 or more (20 or more)49 or more50 or more (20 or more)50 or more (21 or more) 49 or moreWhen a RS-422 conversion unit is installed50 or more (20 or more) 50 or more (39 or more) 50 or more (48 or more) 58 or more –50 or more (20 or more) 50 or more (39 or more) 53 or more 58 or more –When an Ethernet communication unit is installed–50 or more (20 or more)When the CC-Link communication unit (GT15-J61BT13) is installed50 or more (20 or more) 50 or more (24 or more)50 or more (20 or more)50 or more (24 or more)When a MELSECNET/H communication unit (coaxial) is installed 50 or more (20 or more) 50 or more (25 or more) 50 or more (35 or more) 64 or more 50 or more (20 or more) 50 or more (30 or more) 50 or more (35 or more) 64 or moreWhen a MELSECNET/H communication unit (optical) is installed 50 or more (20 or more) ✽1 50 or more (23 or more) ✽1 50 or more (32 or more) ✽1 50 or more (42 or more) ✽1 79 or more 50 or more (20 or more) ✽1 50 or more (23 or more) ✽1 50 or more (37 or more) ✽1 50 or more (42 or more) ✽1 79 or more ✽1When a CC-link IE Controller Network communication unit is installed50 or more (20 or more)57 or more 50 or more (20 or more) 50 or more (23 or more) 50 or more (28 or more) 57 or moreAWhen a CC-Link IE Field Network communication unit is installed50 or more (20 or more)57 or more 50 or more (20 or more) 50 or more (23 or more) 50 or more (28 or more) 57 or moreWhen a printer unit is installed50 or more (20 or more) 50 or more (29 or more)50 or more (20 or more)50 or more (29 or more)When a multimedia unit is installed50 or more (20 or more) ✽2 61 or more ✽2 70 or more ✽2 80 or more ✽2–When a video input unit is installed50 or more (20 or more) ✽2 61 or more ✽2 70 or more ✽2 80 or more ✽2 –61 or more ✽2 75 or more ✽2–When a RGB input unit is installed50 or more (20 or more) ✽350 or more (25 or more) ✽3 –50 or more (20 or more) ✽3 –When a video/RGB input unit is installed50 or more (20 or more) ✽2 ✽3 61 or more ✽2 ✽3 70 or more ✽2 ✽3 80 or more ✽2 ✽3 – 61 or more ✽2 ✽3 75 or more✽2 ✽3–When a RGB output unit is installed50 or more (20 or more) ✽3 50 or more (25 or more) ✽3 – 50 or more (20 or more) ✽3 –When a CF card unit is installed50 or more (20 or more)When a CF card extension unit is installed50 or more (20 or more) 50 or more (49 or more) 58 or more 68 or more 50 or more 50 or more (20 or more) 50 or more (49 or more) 63 or more 68 or more 97 or moreWhen an audio output unit is installed50 or more (20 or more)50 or more50 or more (20 or more)When an external input/output unit is installed50 or more (20 or more) 50 or more (29 or more) 50 or more 50 or more (20 or more) 50 or more (24 or more) 50 or more (29 or more) 58 or moreB80 or more (20 or more)CDE50 or more (20 or more)100 or more (20 or more)(When a CF card is not used)50 or more (20 or more)50 or more (20 or more) ✽4 50 or more (20 or more)(When a CF card is used)50 or more (20 or more)100 or more 50 or more (20 or more)100 or more✽1 : The distance varies depending on the cable to be used. For details, consult your local sales office.The values in the table are given for your reference only and may not reflect actual conditions.✽2 : The distances required when the coaxial cable 3C-2V (JIS C 3501) is used.✽3 : The distance varies depending on the cable to be used. When the bending radius of the cable is larger than the indicated value, keep a space appropriate to the bending radius.✽4 : When using a battery, the required dimension is greater than when using a CF card.GT12(Unit: mm)CGOT main unit A, D B When CF card When CF card Eis not used is usedGT1275GT1265GT11(Unit: mm)CGOT main unit A, D B When CF card When CF card Eis not used is usedGT1155GT115050 or more(20 or more)80 or more ✽1(20 or more)50 or more ✽2(20 or more)100 or more100 or more(20 or more)✽1 : 50 or more (20 or more) in the case of vertical installation✽2 : 80 or more (20 or more) in the case of vertical installationGT10(Unit: mm)GOT main unit A B C D EGT105MGT104M50 or more50 or more 80 or more 50 or more100 or more100 or more50 or more(20 or more)80 or more(20 or more)50 or more(20 or more)50 or more(20 or more)100 or more(20 or more ✽3 )[Fig. A]✽1 : Same dimensions as A985GOT(-V)✽2 : Same dimensions as A975/970GOT(-B)✽3 : Same dimensions as F940GOT✽4 : For the GT104M, GT1030 and GT1020, the tolerances are +1/0.CBADB +2 ✽40Cable model nameGT15-QCMBGT15-QCMBSGT15-CMNBGT15-ACMBGT15-A370CMB-S1GT15-A370CMBGT15-A1SCMBGT15-A1SCMNBGT15-CMEXSS-1 ✽1GT15-EXCNBGT15-CMBSGT15-J2C10B✽1 : GT15-CMEXSS-1 is a set consisting of GT15-EXCNB and GT15-CMBS.(See Fig. A.)[Fig. A]CON1PLC sideBus connection cablesCable length (L)0.6, 1.2, 3, 5, 10m15, 20, 25, 30, 35m1.2, 3, 5m0.6, 1.2, 3, 5m1.2, 2.5m1.2, 2.5m0.7, 1.2, 3, 5m0.45, 0.7, 3, 5m10.6, 20.6, 30.6m0.5m0.7, 1.2, 3, 5, 10, 20, 30m1mGOT sideCON2GOT sideGT15-EXCNB (Fig. 8) GT15-CMBS (Fig. 9)Cable model nameGT16-C02R4-9SGT01-C30R4-25PGT01-CMR4-25PGT01-CMR4-8PGT10-CMR4-8PGT10-CMR4-25PGT10-C10R4-8PLGT10-C02H-9SCCable model nameGT01-C30R2-6PGT01-C30R2-9SGT01-C30R2-25PGT10-C30R2-6PRS-422 cablesCable length (L)0.2m3m10, 20, 30m1, 3, 10, 20, 30m1, 3, 10, 20, 30m3, 10, 20, 30m1m0.2mRS-232 cables3m3m3m3mCable length (L)ExternaldimensionsFig. 1Fig. 1Fig. 2Fig. 3Fig. 4Fig. 5Fig. 6Fig. 7Figs. 8 & 9Fig. 8Fig. 9Fig. 10ExternaldimensionsFig. 11Fig. 12Fig. 13Fig. 14Fig. 15Fig. 16Fig. 17Fig. 18ExternaldimensionsFig. 19Fig. 20Fig. 21Fig. 22RS-485 terminal block conversion unitModel nameFA-LTBGTR4CBLMCable length (L)0.5, 1, 2mExternaldimensionsFig. 23Fig.1Fig.2Fig.3Fig.4Fig.5Fig.11Fig.12Fig.13Fig.14Fig.15Fig.164958584920 60PLC side20 60 L50Cable approx. Ø17.011.5 3211.5 32Motion controllerCPU side3535354232.516101634.514511011070LCable approx. Ø8.0Ferrite core, approx. Ø35 × 40,green holder tubeLCable approx. Ø8.0Ferrite core, approx. Ø35 × 40,green holder tubeLCable approx. Ø8.0Ferrite core, approx. Ø35 × 40,green holder tube505070Ferrite core, approx. Ø32 × 16,green holder tube503211.549GOT side60 2058A7GT-CNB side15 45.5 20038 8503000Ø716 50 L53Ø750 L40Ø6Ø25 × 3353 1630 L 40Ø7 Ø25 × 3325030 L 53Ø7Ø5LCable approx. Ø10Ø25 × 3325095Ferrite core, approx. Ø35 × 40,red holder tubeFig.17 30 1000 3825016131621555513Ø1355Fig.6Fig.7Fig.8Fig.9Fig.10Fig.18Fig.19Fig.20Fig.21Fig.22Fig.2349493511.54911.5223511.55032PLC side11.532PLC sideCON1100A0J2-PW side352133110160LCable approx. Ø8.0 110Ferrite core, approx. Ø35 × 40,green holder tube1000 FG cable500Cable approx. Ø9.033 LFG cable160Cable approx. Ø9.052LCable approx. Ø8.0Ferrite core, approx. Ø35 × 40,green holder tube1000Cable approx. Ø8.05070Ferrite core, approx. Ø35 × 40,green holder tube60 20A7GT-CNB sideGOT sideCON2110Ferrite core, approx. Ø35 x 40,blue holder tube16 50 300053Ø632 11.549GOT side16 50 300050Ø6(Unit: mm)5875 20.5GOT side16 50 300040 13Ø7Ø20 × 2830 3000 408 35L200 45.5 15Approx. Ø30Ø8.1Approx. 48200Ø71850294760(Unit: mm)1649332.516551151335Ø13INDEXFor Designers For Initial Startup & For MaintenanceMELSEC Process Specifications,<strong>Operation</strong>s PersonnelGT10 iQ PlatformControl External DimensionsList of ConnectableModels, etc.GT1030GT102050 or more(20 or more ✽1 )50 or more(20 or more)50 or more(20 or more)50 or more80 or more(20 or more ✽2 )30✽1 : 50 or more when a RS-232/USB conversion adapter is used.✽2 : 80 or more when a personal computer connection cable is used or when a personal computer RS-232interface is used for connecting multiple GOTs.50 or more when a RS-232 interface is used for using an RS-232/USB conversion adapter.✽3 : 80 or more when using a USB cable or a memory board.Ø7Ø25 × 33Ø13Dimensions shown in parentheses apply when there are no devices nearby (contactor, etc.) which produce radiated noise or heat. Even with these dimensions, however, the ambient temperature mustnever exceed 55°C.Depending on the unit and cable being used, a cable length longer than dimension A (or dimension D for the GT10) in above [Fig. A] may be required.62 63

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!