4<br />

<strong>Servicing</strong> Practices<br />

Moisture removal<br />

EXHAUST<br />

OPEN<br />

OPEN<br />

OPEN<br />

VACUUM PUMP<br />

8 - In case <strong>of</strong> closed solenoid valves in the system,<br />

air is usually trapped in-between valves where<br />

they should be opened manually if supplied<br />

with open screws, by applying direct electrical<br />

source to solenoid coil, or by using a service<br />

hand magnet.<br />

9 - Charging <strong>of</strong> refrigerant can now begin, either<br />

direct to the high-pressure liquid side or<br />

charging into the suction side when the<br />

compressor is running.<br />