3<br />

Refrigerant Management<br />

Using the system’s own compressor<br />

If the refrigerant in a system is to be removed and the system has a<br />

working compressor, it is possible to use the compressor to recover<br />

the refrigerant. It may be possible to pump the system down in the<br />

normal way and then decant the refrigerant into a cooled recovery<br />

cylinder, or it may only be possible to use the cooled recovery<br />

cylinder as both condenser and receiver by installing it at the<br />

compressor outlet, as shown in this diagram.<br />

Capillary tube<br />

Closed<br />

Filter-drier<br />

Compressor<br />

operating<br />

Open<br />

Vapor valve<br />

open<br />

Recovery Cylinder<br />

packed in ice<br />

Using the compressor<br />

to recover the refrigerant<br />

72