01.12.2012 Views

Manual for Refrigeration Servicing Technicians - UNEP - Division of ...

Manual for Refrigeration Servicing Technicians - UNEP - Division of ...

Manual for Refrigeration Servicing Technicians - UNEP - Division of ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2<br />

Refrigerants<br />

Application<br />

Industrial<br />

Process<br />

<strong>Refrigeration</strong><br />

Refrigerated<br />

Transport<br />

Split and<br />

ducted air<br />

conditioners<br />

Portable and<br />

window<br />

Application<br />

units<br />

Heat Pumps<br />

Chillers<br />

Mobile air<br />

conditioning<br />

(MAC)<br />

Traditional<br />

refrigerants<br />

R22<br />

R502<br />

R717<br />

R290/<br />

R1270<br />

R12<br />

R502, R22<br />

R22<br />

R22 Traditional<br />

refrigerants<br />

R22<br />

R11<br />

R123<br />

R12<br />

R22<br />

R12<br />

Retr<strong>of</strong>it / drop-in refrigerants<br />

Transitional Longer term<br />

R408A (HT), R411A,<br />

R411B, R412A,<br />

R415A, R418A<br />

R401A, R401C,<br />

R405A, R406A,<br />

R409A (HT), R414A,<br />

R414B, R415B,<br />

R416A (HT), R420A<br />

(HT)<br />

R408A (HT), R411A,<br />

R411B, R412A,<br />

R415A, R418A<br />

R408A, R411A,<br />

R411B, R412A,<br />

R415A, R418A<br />

R417A, R419A (HT),<br />

R422B, R422D,<br />

R424A, R431A,<br />

R438A<br />

R426A, R429A (HT),<br />

R430A, R435A,<br />

R436A*, R436B*,<br />

R437A (LT)<br />

R290*,R417A,<br />

R419A (HT), R422B,<br />

R422D, R424A,<br />

R431A, R438A<br />

R290*,R417A,<br />

R419A, R422B,<br />

R422D, R424A,<br />

R431A, R438A<br />

R290*,R417A,<br />

R408A, R411A,<br />

R411B, R412A,<br />

Retr<strong>of</strong>it / drop-in R419A, refrigerants R422B,<br />

R422D, R424A,<br />

R415A, R418A<br />

Transitional R431A, Longer R438A term<br />

R408A, R411A,<br />

R411B, R412A,<br />

R415A, R418A<br />

R290*,R417A,<br />

R419A, R422B,<br />

R422D, R424A,<br />

R431A, R438A<br />

New system refrigerants<br />

R404A, R407A/B/D/E, R421A,<br />

R421B, R427A, R433A/B/C,<br />

R507A, R744, Indirect systems<br />

(using R290*, R1270*), R717*<br />

R134a, R423A, R435A, R436A*,<br />

R436B*, R510A*<br />

R404A, R407A/B/D/E, R421A,<br />

R421B, R427A, R433A/B/C,<br />

R507A, R744, R290*, R1270*<br />

R407A/C/D/E, R421A, R427A,<br />

R433A/B/C, R290*, R1270*, R410A<br />

R407A/C/D/E, R421A, R427A,<br />

New R433A/B/C, system refrigerants R290*, R1270*, R410A<br />

R407A/C/D/E, R421A, R427A,<br />

R433A/B/C, R744, R290*, R1270*,<br />

R410A<br />

None None R236ea, R236fa, R245fa<br />

R401A, R401C,<br />

R405A, R406A,<br />

R409A, R414A,<br />

R414B, R415B,<br />

R416A, R420A<br />

R408A, R411A,<br />

R411B, R412A,<br />

R415A, R418A<br />

R401A, R401C,<br />

R405A, R406A,<br />

R409A, R414A,<br />

R414B, R415B,<br />

R416A, R420A<br />

R426A, R429A,<br />

R430A, R435A<br />

R290*,R417A,<br />

R419A, R422B,<br />

R422D, R424A,<br />

R431A, R438A<br />

R426A, R429A,<br />

R430A, R435A,<br />

R436A*, R436B*<br />

R134a, R423A, R435A<br />

R407A/C/D/E, R421A, R427A,<br />

R433A/B/C, R744, R290*, R1270*,<br />

R410A<br />

R134a, R744<br />

A number <strong>of</strong> additional observations are made:<br />

• Many <strong>of</strong> the blends in the “longer term” and “new<br />

system” lists contain HFCs and PFCs, which are<br />

included in the Kyoto Protocol, and are being<br />

legislated against in several European counties.<br />

• Flammable refrigerants – indicated with an asterisk (*)<br />

must be handled appropriately, that is, systems are<br />

designed and maintained according to safety rules. If<br />

they are used as a drop-in refrigerant, the technician<br />

must ensure that the conversion has been done<br />

according to the appropriate safety rules.<br />

• The initials “(HT)” and “(LT)” imply that the refrigerant<br />

is more suited to high temperature (eg, chilled food) or<br />

low temperature (eg. frozen food), respectively.<br />

• In addition to the refrigerants listed, there are many<br />

other products on the market that do not have an<br />

R-number. Similarly, many <strong>of</strong> the refrigerants listed<br />

are marketed under trade names, rather than the<br />

R-number.<br />

• Systems using carbon dioxide systems need to be<br />

designed with particular respect to its thermodynamic<br />

characteristics.<br />

54