2<br />
Refrigerants<br />
Refrigerants and applications<br />
Application<br />
Domestic<br />
refrigeration<br />
Stand alone<br />
retail food<br />
display and<br />
vending<br />
Condensing<br />
Units<br />
Large<br />
Supermarket<br />
Systems<br />
Cold Storage<br />
Traditional<br />
refrigerants<br />
R12<br />
R12<br />
R22, R502<br />
R502<br />
R22<br />
R502<br />
R502<br />
R22<br />
R717<br />
Retr<strong>of</strong>it / drop-in refrigerants<br />
Transitional Longer term<br />
R401A, R401C,<br />
R405A, R406A,<br />
R414A, R414B,<br />
R415B<br />
R401A, R401C,<br />
R405A, R406A,<br />
R409A (HT), R414A,<br />
R414B, R415B,<br />
R416A (HT), R420A<br />
(HT)<br />
R408A (HT), R411A,<br />
R411B, R412A,<br />
R415A, R418A<br />
R408A (HT), R411A,<br />
R411B, R412A,<br />
R415A, R418A<br />
R408A (HT), R411A,<br />
R411B, R412A,<br />
R415A, R418A<br />
R408A (HT), R411A,<br />
R411B, R412A,<br />
R415A, R418A<br />
R426A, R430A,<br />
R435A, R436A*,<br />
R436B*, R437A<br />
R426A, R429A (HT),<br />
R430A, R435A,<br />
R436A*, R436B*,<br />
R437A (LT)<br />
R290*, R417A,<br />
R419A (HT), R422B,<br />
R422D, R424A,<br />
R431A, R438A<br />
R417A, R419A (HT),<br />
R422B, R422D,<br />
R424A, R431A,<br />
R438A<br />
R417A, R419A (HT),<br />
R422B, R422D,<br />
R424A, R431A,<br />
R438A<br />
R417A, R419A (HT),<br />
R422B, R422D,<br />
R424A, R431A,<br />
R438A<br />
New system refrigerants<br />
R134a, R600a*<br />
R600a*, R134a, R423A, R435A,<br />
R436A*, R436B*, R510A<br />
R290*, R404A, R407A/B/D/E,<br />
R421A, R421B, R427A,<br />
R433A/B/C, R507A, R744<br />
R404A, R407A/B/D/E, R421A,<br />
R421B, R427A, R433A/B/C,<br />
R507A, R744<br />
R404A, R407A/B/D/E, R421A,<br />
R421B, R427A, R433A/B/C,<br />
R507A, R744, Indirect systems<br />
(using R290*, R1270*, R717*)<br />
R404A, R407A/B/D/E, R421A,<br />
R421B, R427A, R433A/B/C,<br />
R507A, R744, Indirect systems<br />
(using R290*, R1270*), R717*<br />
The chart presents an overview <strong>of</strong> main alternative<br />
refrigerants to CFCs and HCFCs in diverse RAC applications.<br />
For each application, there are four lists <strong>of</strong> refrigerants:<br />
• Traditional refrigerants, what would usually have been<br />
used prior to the Montreal Protocol.<br />
• Retr<strong>of</strong>it / drop-in refrigerants, are refrigerants that have<br />
been developed, or can be used in existing systems<br />
that contained the traditional refrigerants, and<br />
typically contain some HC component so that they<br />
are soluble with existing mineral oils.<br />
These have been divided into two further categories:<br />
• Transitional refrigerants that comprise some HCFCs,<br />
and are there<strong>for</strong>e still controlled by the Montreal<br />
Protocol, and should only considered <strong>for</strong> short-term<br />
use in systems that contained CFCs.<br />
• Long-term refrigerants that do not comprise any<br />
ozone depleting substances, and can be considered<br />
to be unrestricted.<br />
• New system refrigerants, which include refrigerants<br />
that are also not restricted by the Montreal Protocol<br />
and are expected to be applicable <strong>for</strong> the long term.<br />
53