12.07.2015 Views

standard construction details - The Management System Parking Lot

standard construction details - The Management System Parking Lot

standard construction details - The Management System Parking Lot

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

PHOTOELECTRIC CONTROL6’-0"LIGHT FIXTUREAS SPECIFIED2118"AAREMOVABLETOPA1’A1’2’-6" OBOLT CIRCLE ASSPECIFIED ON PLANS2" SCHEDULE 40 PIPEA2’-0" OASTREET LIGHTCONDUIT26"TWO BOLTARM ATTACHMENT2"4" THICK MEDIAN PVM’T.12"22"24"BARE #6COPPER GROUNDWIRE2" MIN3" MIN18"MIN13"MOUNTING HEIGHT AS SPECIFIEDLIME STABILIZED BASEITEM 680STREET LIGHTCONDUITSECTION A-A6"1’-6"APPROX18"18"RSANDSTREET LIGHTCONDUITFLUSH MOUNTED PULL BOX DETAILITEM 68830"FOUR CONNECTING BOLTSSHOULD ACCOMODATE 11"BOLT CIRCLE OF POLE BASESTREET LIGHTCONDUIT18"MINSTREET LIGHT CONDUIT INSTALLATION DETAIL13"PLATE4-1"x40" GALVANIZEDIRON ANCHOR BOLTSTO BE PROTECTED3-#4 STIRRUPS5’-0"PRIOR TO INSTALLATIONINSTALL CONDUIT ADJACENT TO NORTH CURB OF MEDIANOF STANDARDS BY T.U.ON STREETS THAT RUN EAST AND WEST.4-#5 BARSINSTALL CONDUIT ADJACENT TO THE WEST CURB OF MEDIANON STREETS THAT RUN NORTH AND SOUTH.20"CONTRACTOR TO FURNISH BOLT2 "4’-0" LONGCIRCLE TEMPLATE, ANCHOR BOLTS,2"PVC, GROUNDING PLATE, ANDPULL STRING.EQUAL TO POLE DIA AT BASEH A N D H O L EWITH REINFORCEDFRAME AND COVERSTREET LIGHT FIXTURESI N S T A L L W E ACONDUIT AND CONDUCTORSTO HEIGHT SPECIFIED BYT.U. CO.FUSED SAFETY SWITCH INNEMA 3R ENCLOSURE.INSTALL SWITCH APPROX. 10’ABOVE GRADE. (SIZE FUSE ANDSWITCH AS SPECIFIED)3" MIN24"16"20 GAUGE COPPER PLATE7 TRANSFORMER BASE DETAIL3000 P.S.I. REINFORCED CONCRETE FOUNDATIONTRANSFORMER BASE SHALL BE MOUNTED ONFOUNDATION WITH A 15" DIA. BOLT CIRCLE.FOUNDATION FOR STREET LIGHT ONLY OR FORCOMBINATION STREET LIGHT AND TRAFFIC SIGNALSEE DETAIL FOR ANCHOR BOLT CIRCLE REQUIREMENTS.682 6813"684683GROUND LUG191111"715"1STREET LIGHT DETAILNO SCALETO OTHER LIGHTSON POLE1 " R I G I D M E T ATO 24" BELOW GRADE (INSTALL11" O BOLT CIRCLE-USEDWHENEVER POLE IS15" O BOLT CIRCLE-USEDSINGLE OR DOUBLE STREET LIGHT WITH 150 WATT HPSFIXTURE(S) AND 32.5 NOMINAL MOUNTING HEIGHTLUMINAIRE SHALL BE GENERAL ELECTRIC M-250RCAT. NO. C760N545, OR EQUAL. PHOTOELECTRIC CONTROLSIZE WIRE &CONDUIT ASCONDUIT ON T.U. POLE ASSPECIFIED.)1 3 " B O L TWHENEVER STANDARD ISMOUNTED DIRECTLY ONFOUNDATION.1 7 " B O L TWHENEVER TRANSFORMER BASEIS MOUNTED DIRECTLY ONFOUNDATION.MOUNTED DIRECTLY ONFOUNDATION.WHENEVER TRANSFORMER BASEIS MOUNTED ON FOUNDATION.SHALL BE INCLUDED.SPECIFIEDGROUND WIRE INFOUNDATION" O x 8 ’FOR 40’ STANDARDFOR 30’ STANDARDPOLE SHALL BE UNION METAL DESIGN 1400A, CAT.NO. H-296-82 OR EQUAL. POLES FOR SINGLE LIGHTSSHOULD BE ORDERED WITH DOUBLE MOUNTINGANCHOR BOLT CIRCLE REQUIREMENTSAPPROVEDATTACHMENTS. (ALLOWS FOR FUTURE INSTALLATIONOF ADDITIONAL ARM AND FIXTURE.)TYPICAL DOUBLE STREETLIGHT RISER DETAILTYPICAL SERVICE RISER DETAILDIRECTOR OF PUBLIC WORKS & TRANSPORTATIONDATE:MISCELLANEOUS DETAILSINSULATED CONDUCTOR USED FORTHE HOT LEG SHALL BE SUITABLE FORONLY RIGID METAL CONDUIT SHALL BE USED ABOVEGRADE.STREET LIGHTEQUIPMENT DETAILSDIRECT BURIAL.A BARE CONDUCTOR MAY BE USED FORTHE NEUTRAL.CONTRACTOR SHALL MAKE ALL ARRANGEMENTS FORSERVICE WITH T.U. CO.DEPARTMENT OF PUBLIC WORKS & TRANSPORTATIONCITY OF DALLAS, TEXASDESIGN DRAWN DATE FILE NO. PAGE NO.APRILC.O.D. A.B.&A. 251D 119979009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!