12.07.2015 Views

standard construction details - The Management System Parking Lot

standard construction details - The Management System Parking Lot

standard construction details - The Management System Parking Lot

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

NO FE NCING OR CO NST RUNOTE:TRENCH WIDTHS BASED ON1.25 Bc+1.0 WHERE Bc ISPIPEDIAMETER(INCHES)TRENCHWIDTH(FEET)24"COMPACTED BACKFILL TO95% MIN. DENSITYTHE OUTSIDE DIAMETER OFTHE PIPE IN FEET.1518213.03.43.8244.1COMPACTED BACKFILL 90%PROCTOR MINIMUM DENSITYNATURAL GROUNDOR ROCK27334.55.236425.66.348 7.054 7.860 8.566 9.2SELECT BACKFILL SALVAGED FROM TRENCH 72 10.0EXCAVATION MUST BE CLEAN AND FREE78 10.7OF LARGE ROCKS. IT MUST BE APPROVED8411.4BY THE ENGINEER AND STOCKPILED FORUSE WHEN NEEDED. IF ACCEPTABLE MAT-9012.1ERIAL IS NOT AVAILABLE, FLOWABLE BACKFILL96 12.9PER NCTCOG ITEM 2.15 (e) & (f) WILL BEREQUIRED.EMBEDMENT MATERIALDEPTH OF BEDDINGCRUSHED ROCKMATERIAL BELOWGRADATION: 0 RETAINED ON 1 1/4"PIPE95%-100% RETAINEDON NO. 10D (Inside Diameter) d (Min)27" OR SMALLER 3"30" TO 60" 4"66" & LARGER 6"d=DEPTH OF BEDDING MATERIAL BELOW PIPE.TRENCH WIDTHS SHOWN ARE MINIMUM FOR PROPERPLACEMENT AND COMPACTION OF EMBEDMENT ANDH=BACKFILL COVER ABOVE TOP OF PIPE.BACKFILL.TRENCH WIDTHS SHOWN WILL BE USED FOR CALCU-LATION OF ROCK EXCAVATION WHEN DESIGNATEDAS A PAY ITEM.6" 6"VARIESVARIES6"MIN.PREFAB. INLET BOX INSTALLATION6"MIN.dTOP OF SUBGRADEHConcreteGroundNO SCALE2’-0" 1’-0"Formed3000 psiD OF LO OD WAY3 1/4"+N O T DCT ION BE Y ON D T H IS P O IN TMAR KE R5/8" DIAM.REINF. RODBERNTSEN ModelROD 5325 ORIS T U R B3 1/4"24" 1/4"BACKFILL AROUND PIPEFLOWABLE FILL OR COMPACTEDSELECT MATERIAL FROMTRENCH EXCAVATION.90% PROCTOR MIN. DENSITYNOTE:Where Street or Alley iscrossed by the Storm Sewera 95% Proctor Min. DensityBc/2 1/8 H6" MINBcEQUALwill be required up to bottomof proposed subgrade.FLOOD MANAGEMENT MONUMENTIN NATURAL GROUNDREINFORCED CONCRETE CLASS IIIPIPE INSTALLATIONNOTE:FOR H>10’ DESIGN MUST BE CHECKED. UNLIMITED TRENCHWIDTH WILL NOT BE PERMITTED FOR CLASS III PIPE ANDHIGHER TYPE PIPE EMBEDMENT MAY BE REQUIRED.INSTALLATION WILL BE AS SHOWN OR AS DESCRIBEDIN THE GENERAL SPECIFICATIONS FOR CONSTRUCTIONTOP 24" OF BACKFILL MUST BE COMPACTEDTO 95% DENSITYUNDER PAVEMENT. SUBGRADE STABILIZATION UNDER STREETPAVEMENT SHALL BE COMPACTED TO 98% STANDARD PROCTORDENSITY AT +-2% OF OPTIMUM MOISTURE TO THE DEPTH SHOWNON THE PLANS AND IN ACCORDANCE WITH THE SPECIFICATIONS.MAXIMUM4:1 SLOPECAST IN PLACE INLET TOPAND TRANSITION REQUIRED6" 6"DETAIL OF CONCRETE COLLARFOR END TO END EXTENSIONS6" 6"6" FOR BACKFILL WITHFLOWABLE FILL TO FILL VOIDSOR COMPACT WITH SELECT SURPLUSEXCAVATION COMPACTED IN 8" LIFTSTO 95% STANDARD PROCTOR DENSITY.ROCK 3"ROCK FOUNDATION3" UNDERCUT FOR PLACEMENT OF PIPE BEDDINGAPPROVEDDATE:DIRECTOR OF PUBLIC WORKS & TRANSPORTATIONDRAINAGE DETAILSCONCRETE PIPE INSTALLATIONDEPARTMENT OF PUBLIC WORKS & TRANSPORTATIONCITY OF DALLAS, TEXASDESIGN DRAWN DATE FILE NO. PAGE NO.APRILC.O.D. A.B.&A. 251D 119972006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!