12.07.2015 Views

Form 186 - Baldwin Filters

Form 186 - Baldwin Filters

Form 186 - Baldwin Filters

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

BD7154 & BD7309 Lube Spin-onsBD103 Lube Spin-onB96 Lube Spin-onBF7766 Fuel Spin-on<strong>Baldwin</strong> <strong>Filters</strong> WarrantySteel Coil Springkeeps its shape,maintaining apositive load pressureon the elements.100% SyntheticMicroglass TM Mediaspecifically developed toincrease structuralstrength, efficiency andcontaminant capacity.Patent PendingDesign providesmaximum contaminantholding capacity andcontaminant removalefficiency, while minimizingflow restriction duringoperation and cold start-ups.Heavy-Duty SteelRetainer and End Capare welded together toprevent the post sealfrom dislodging.Heavy-Duty,All-Metal Housingprovides unequaled burstandpulse-withstandingstrength.Spiral WoundLouvered Centertubewith fluted ribs allowsfor maximum flow andadds strength to resistpressure surges.High VelocityDual-Flow ® Nozzleuses a venturi-type cone tobalance the flow betweenthe elements, takingadvantage of the positivefiltering properties of each.Heavy-DutySteel Baseplateis joined to the can witha J-lock seam, reducingthe possibility of leakagedue to high pressure.Illustration is representative of the BD7154. The BD7309 utilizes a proven steel baseplate with a double-rolled, tuck lock seam.Contaminant Removal EfficiencyBD7154 69.5%LF9080 51.2%0% 10% 20% 30% 40% 50% *60% 70% 80% 90% 100%ISO 4548-12 Test: Flow Rate 28 gpm, 100ºF, Termination at 10 psidEfficiency time weighted average at 10 microns. * Cummins Engine Standard 10765 minimum efficiency = 60.0%Contaminant Holding CapacityBD7154 61.4gLF9080 45.2g0g 10g 20g 30g 40g 50g 60g 70g 80g 90g 100gISO 4548-12 TestContaminant Removal EfficiencyBD7309 70.9%BD7154BD7154BD7309Steel Coil Springkeeps its shape,maintaining apositive load pressureon the adapter seal.Cellulose/SyntheticBlend Mediaspecifically developed toincrease structuralstrength, efficiency andcontaminant capacity.Patented SeriesDesign provides upto 43 percent morefiltering surface toincrease contaminantholding capacity andelement life. Full-flowand by-pass elementsrun almost the fulllength of the filterenclosure.Contaminant Removal EfficiencyHeavy-Duty,All-Metal Housingprovides unequaled burstandpulse-withstandingstrength.Spiral WoundLouvered Centertubewith fluted ribs allowsfor maximum flow andadds strength to resistpressure surges.Radial Post Sealseparates the full-flowportion of the filter fromthe by-pass.Full-Flow Spud Sealseparates the clean oilfrom the dirty return oil.Heavy-Duty Baseplateis joined to the can witha double-rolled, tuck lockseam to resist leakagedue to high pressureand vibration.BD103 96.4%LF3000 95.3%0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%Steel Coil Springkeeps its shape,maintaining apositive load pressureon the adapter seal.Cellulose/SyntheticBlend Mediaspecifically developed toincrease structuralstrength, efficiency andcontaminant capacity.0%Contaminant Removal EfficiencyHeavy-Duty,All-Metal Housingprovides unequaled burstandpulse-withstandingstrength.Spiral WoundLouvered Centertubewith fluted ribs allowsfor maximum flow andadds strength to resistpressure surges.Heavy-Duty Baseplateis joined to the can witha double-rolled, tuck lockseam to resist leakagedue to high pressureand vibration.B96 91.4%LF670 87.8%10% 20% 30% 40% 50% 60% 70% 80% 90% 100%Steel Coil Springkeeps its shape,maintaining apositive load pressureon the elements.High EfficiencyInterBlend TM Mediacombines layers ofpolyester and celluloseto increase contaminantremoval efficiency andcontaminant holdingcapacity.Heavy-Duty SteelRetainer and End Capare welded together toprevent the post sealfrom dislodging.0%Contaminant Removal EfficiencyBF7766 91.2%FF2200 86.2%Heavy-Duty,All-Metal Housingprovides unequaled burstandpulse-withstandingstrength.Spiral WoundLouvered Centertubewith fluted ribs allowsfor maximum flow andadds strength to resistpressure surges.Heavy-DutySteel Baseplateis joined to the can witha J-lock seam, reducingthe possibility of leakagedue to high pressure.10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<strong>Baldwin</strong> <strong>Filters</strong>, Inc. (“<strong>Baldwin</strong>”) warrants that each new product manufactured by <strong>Baldwin</strong> will be made freeof defects in workmanship and material. <strong>Baldwin</strong> will replace any product found to be defective when youreturn it to <strong>Baldwin</strong> or to your <strong>Baldwin</strong> distributor where you purchased the product.Return ProcessYou should first contact your salesperson at <strong>Baldwin</strong> or at your <strong>Baldwin</strong> distributor if you purchased aproduct that you believe does not meet the warranty stated above. The salesperson will help you completethe necessary paperwork, and will also help you return the suspected defective product to <strong>Baldwin</strong> foranalysis.Warranty FulfillmentIf <strong>Baldwin</strong> finds that a returned product does not meet the warranty stated above, <strong>Baldwin</strong> will promptlyreplace the defective product. If the defective product directly caused damage to the machine on which itwas installed, <strong>Baldwin</strong> will promptly reimburse the machine owner for that portion of the repair costs thatwere necessary to restore the machine to its condition immediately prior to the damage caused by thedefective product.Conditions<strong>Baldwin</strong>’s warranty fulfillment obligations above do not apply if: a) the product is not returned to <strong>Baldwin</strong> foranalysis, b) <strong>Baldwin</strong> finds that the product was not defective, c) the product was improperly installed or used,d) the product was reused or not replaced inside a normal service interval, or e) the product is tamperedwith or damaged in a manner that may inhibit <strong>Baldwin</strong>’s ability to conduct a warranty investigation.The above warranty and warranty fulfillment obligations are exclusive and in lieu of all otherwarranties or related remedies. <strong>Baldwin</strong> is not liable for indirect, incidental, punitive orconsequential damages arising in any way from the products it manufactures or sells.Africa<strong>Baldwin</strong> <strong>Filters</strong>, Pty. Ltd.Ph: 27-21-534-0029E-mail: africa@baldwinfilter.comAustralia & New Zealand<strong>Baldwin</strong> <strong>Filters</strong> Aust., Pty. Ltd.Ph: 61-3-9353-7300E-mail: australia-newzealand@baldwinfilter.comCentral & South America<strong>Baldwin</strong> <strong>Filters</strong>Ph: (308) 233-9220E-mail: latinamerica@baldwinfilter.comChinaCLARCOR Filtration (China) Co., Ltd.Ph: 86-0536-2606308E-mail: china@baldwinfilter.comEurope<strong>Baldwin</strong> <strong>Filters</strong> N.V.Ph: 32 3 328 18 88E-mail: europe@baldwinfilter.comMexico<strong>Baldwin</strong> <strong>Filters</strong>, S. de R. L. de C. V.Ph: 52-442-227-3400E-mail: mexico@baldwinfilter.comMiddle East<strong>Baldwin</strong> <strong>Filters</strong>Ph: (308) 237-9782E-mail: middleeast@baldwinfilter.comMorocco<strong>Baldwin</strong> <strong>Filters</strong> MoroccoPh: (212) 522 70 00 25E-mail: morocco@baldwinfilter.comRussia<strong>Baldwin</strong> <strong>Filters</strong>Ph: (308) 237-9749E-mail: russia@baldwinfilter.comSoutheast Asia & Pacific Rim<strong>Baldwin</strong> <strong>Filters</strong>Ph: (308) 233-9226E-mail: southeastasia@baldwinfilter.comUK & Ireland<strong>Baldwin</strong> <strong>Filters</strong> Ltd.Ph: 44-1268-888170E-mail: uk-ireland@baldwinfilter.comLF9009 73.9%0% 10% 20% 30% 40% 50% *60% 70% 80% 90% 100%ISO 4548-12 Test: Flow Rate 28 gpm, 100ºF, Termination at 10 psidEfficiency time weighted average at 10 microns. * Cummins Engine Standard 10765 minimum efficiency = 60.0%Contaminant Holding CapacityBD7309 61.8gLF9009 46.1gBD7309SAE HS806 Test: Flow Rate 20 gpm, ISO Fine Test Dust, Dust Add Rate 5g/hr, Termination at 20 psidEfficiency time weighted average.Contaminant Holding CapacityBD103 104.5gLF3000 47.1gSAE HS806 Test: Flow Rate 20 gpm, ISO Fine Test Dust, Dust Add Rate 5g/hr, Termination at 28 psidEfficiency time weighted average.Contaminant Holding CapacityB96 98.2gLF670 75.2gSAE J905 Test: Flow Rate 90 gph, ISO Fine Test Dust, Dust Add Rate 8g/4g, Termination at 4 psidEfficiency time weighted average.Contaminant Holding CapacityBF7766 73.6gFF2200 71.1g0g 10g 20g 30g 40g 50g 60g 70g 80g 90g 100gISO 4548-12 Test0g 15g 30g 45g 60g 75g 90g 105gSAE HS806 Test0g 10g 20g 30g 40g 50g 60g 70g 80g 90g 100gSAE HS806 Test0g 10g 20g 30g 40g 50g 60g 70g 80g 90g 100gSAE J905 Test<strong>Form</strong> <strong>186</strong> (R 9/13) © 2013 <strong>Baldwin</strong> <strong>Filters</strong>, Inc. Printed in U.S.A.


BF1277-SPS Fuel/Water SeparatorsBF1259 Fuel/Water SeparatorBF1212 Fuel/Water SeparatorBF957 Fuel Spin-onSensor PortConnectionaccepts the OEM sensor.Spiral WoundLouvered Centertubewith fluted ribs allowsfor maximum flow andadds strength to resistpressure surges.Heavy-DutyAluminum Baseplateis joined to the can witha J-lock seam, reducingthe possibility of leakagedue to high pressure.Reusable Sensorindicates the presence of water in thefuel and is included with the BF1277-SPS.* The BF1277-SP does not include the reusable water sensor as part of the filter.Contaminant Removal EfficiencyBF1277-SPS 86.7%All-Metal,Self-Venting Draineliminates the need toseparately vent the fuelsystem prior to draining,while adding superiorstructural strength andease of service.Steel Coil Springkeeps its shape,maintaining apositive load pressureon the adapter seal.Heavy-Duty,All-Metal Housingprovides unequaled burstandpulse-withstandingstrength.High EfficiencyHydroShield TMMediawas developed to repelwater while maximizingstrength, efficiency andcontaminant capacity.BF1277-SPSBF1277-SPHeavy-Duty,All-Metal Housingprovides unequaled burstandpulse-withstandingstrength.High EfficiencyInterBlend TM Mediacombines layers ofpolyester and celluloseto increase contaminantremoval efficiency andcontaminant holdingcapacity.Easy-Opening Valvehas one seal instead ofthree and requires 88percent less torque toopen and close.Contaminant Removal EfficiencyHeavy-Duty Baseplateis joined to the can witha double-rolled, tuck lockseam to resist leakagedue to high pressureand vibration.MoldedStandpipe/Centertubehelps to protect highhorsepower enginesfrom hard start problemsand to prevent collapsecaused by a suddendifference betweeninternal and externalpressure.All-Metal,Self-Venting Draineliminates the need toseparately vent the fuelsystem prior to draining,while adding superiorstructural strength andease of service.BF1259 99.9%FS1000 99.9%Cummins Specifications 98.7%0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%SAE J1985 Test: Flow Rate 90 gph, ISO Fine Test Dust, 100ºF, Termination at 60 minutesEfficiency time weighted average at 10 microns.Emulsified Water Removal CapabilityBF1259 98.9%Heavy-Duty,All-Metal Housingprovides unequaled burstandpulse-withstandingstrength.Spiral WoundLouvered Centertubewith fluted ribs allowsfor maximum flow andadds strength to resistpressure surges.Easy-Opening Valvehas one seal instead ofthree and requires 88percent less torque toopen and close.Contaminant Removal EfficiencyBF1212 91.4%FS1212 91.5%0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%SAE J905 Test: Flow Rate 90 gph, ISO Fine Test Dust, Dust Add Rate 4g/2g, Termination at 4 psidEfficiency time weighted average.Contaminant Holding CapacityBF1212 32.0gFS1212 31.0gHighly EffectiveHydroShield TM Mediarepels water and othercontaminants andprovides an averageof 37 percent moreholding capacity.All-Metal,Self-Venting Draineliminates the need toseparately vent the fuelsystem prior to draining,while adding superiorstructural strength andease of service.0g 10g 20g 30g 40g 50gSAE J905 TestHeavy-Duty,All-Metal Housingprovides unequaled burstandpulse-withstandingstrength.High Efficiency Mediadesigned to meet orexceed the requirementsof each particular system.Contaminant Removal EfficiencyBF957 84.1%FF105 80.5%0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%SAE J905 Test: Flow Rate 90 gph, ISO Fine Test Dust, Termination at 4 psidEfficiency time weighted average.Contaminant Holding CapacityBF957 16.6gFF105 11.9gSteel Coil Springkeeps its shape,maintaining apositive load pressureon the adapter seal.Spiral WoundLouvered Centertubewith fluted ribs allowsfor maximum flow andadds strength to resistpressure surges.Heavy-Duty Baseplateis joined to the can witha double-rolled, tuck lockseam to resist leakagedue to high pressureand vibration.0g 5g 10g 15g 20g 25gSAE J905 Test0%FS1040 86.6%10% 20% 30% 40% 50% 60% 70% 80% 90% 100%SAE J905 Test: Flow Rate 150 gph, ISO Fine Test Dust, Dust Add Rate 8g/4g, Termination at 4 psidEfficiency time weighted average.Contaminant Holding CapacityBF1277-SPS 73.1gFS1040 57.2gSAE J905 TestBF1277-SPSBF1277-SP0g 10g 20g 30g 40g 50g 60g 70g 80g 90g 100gFS1000 90.7%Cummins Specifications 95.0%0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%SAE J1488 Test: Flow Rate 90 gph, 80ºF, Bar graph shows average efficiency over the life of the testContaminant Holding CapacityBF1259 55.1gFS1000 50.5gCummins Specifications 52.0g0g 10g 20g 30g 40g 50g 60g 70g 80g 90g 100gSAE J905 Test: Flow Rate 90 gph, ISO Fine Test Dust, 100ºF, Termination at 4 psidCUMMINS ® CROSS-REFERENCECummins ® <strong>Baldwin</strong> ® Donaldson ® Fleetguard ® Cummins ® <strong>Baldwin</strong> ® Donaldson ® Fleetguard ®3315843 BF1212 P558000 FS12123315844 BF957 P550105 FF1053331096 BF1274-SP (1) P551047 FS10073401544 BD7309 ELF7300 LF90093406809 BD7154 P559000 LF90803406810 BD7153 — LF90703685306 BF9860 — FF56863825970 BD103 P553000 LF30003889310 B96 P551670 LF6703889311 B7577 P550777 LF7773889716 BF1259 P551000 FS10003937736 B7177 P550428 LF39704010651 BF1277-SP (2) P551047 FS10404088272 BF7766 P552200 FF2200(1) – with sensor, order BF1274-SPS(2) – with sensor, order BF1277-SPSCummins ® is a registered trademark of Cummins Inc.There is no association or affiliation between<strong>Baldwin</strong> <strong>Filters</strong> and Cummins Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!