<strong>XLC</strong> Second <strong>Stage</strong> <strong>Service</strong> & Repair <strong>Manual</strong> 17Table 4Torque SpecificationsPART NUMBER DESCRIPTION / KEY NUMBER TORQUE1005-35, -36, or -37 LP Hose Female Fitting / 16 40 (±3) inch-lbs1041-06 Inlet Fitting/ 20 50 (±5) inch-lbsTable 5Test Bench SpecificationsTEST CONDITION ACCEPTABLE RANGELeak test Inlet 2,500-3,000 (±100) psi NoneIntermediate pressure Inlet 2,500-3,000 (±100) psi 135-140 psiIntermediate pressure creep Inlet 2,500-3,000 (±100) psi5 psi max between 5 to 15 secondsafter cycling regulator (purge)Opening effort Inlet 2,500-3,000 (±100) psi, +.8 to +1.4 inch H 20 (primary)intermediate pressure 135-140 psi +.8 to +1.8 inch H 20 (octopus)Flow effort Intermediate pressure 135-140 psi +6 inches H 20 (maximum)at 15 SCFMPurge flow Intermediate pressure 135-140 psi 5.0 SCFM flow rate (minimum)© 1999 Aqua Lung America, Inc.