Cube Weight AdjustmentThe cube weight can be increased from the factorysetting by adjusting the finish time.ADDITIONAL FINISHING TIME CHECK1. Press and hold the power button for 5 seconds.2. Count the flashes on the Automatic Ice Makinglight. The light will flash once for each additionalminute of freeze cycle time.ADJUSTING FINISHING TIMEAdjust in 1 minute increments and allow the icemachine to run several freeze/harvest cycles, theninspect the ice cubes. If a heavier cube weight isdesired add another minute of freeze time and repeatthe process.1. Press and hold the “Power” button.2. Press and release the “Clean” button once foreach additional minute of freeze cycle timedesired.3. Five minutes is the maximum additional freezetime that can be added. Pressing the clean button6 times will reset the finishing time to zeroadditional minutes.REPLACEWATER FILTERPOWERAUTOMATICICEMAKINGDELAYSTART2 4 8HOURSCLEANTO RESET:PUSH AND HOLD CLEANBUTTON FOR 6 SECONDSSM050 Control PanelSM050 Ice CubePart Number 80-01111-9 7/10 97