QM20/QM30/QM45Do not purge refrigerant to the atmosphere. Capturerefrigerant using recovery equipment. Follow themanufacturer’s recommendations.Important<strong>Manitowoc</strong> Ice assumes no responsibility for theuse of contaminated refrige rant. Damag eresulting from the use of contaminated refrigerantis the sole responsibility of the servicing company.ImportantReplace the liq uid line drie r before e vacuatingand recharging. Use onl y a Man itowoc (O.E.M.)liquid lin e filter drier to preven t voidi ng th ewarranty.CONNECTIONSThe QM series ice machines are critically charged.There are no refrigerant access ports on QM series icemachines.1. Locate the high and low side process tubes.2. Install a piercing valve (saddle valve) on both thehigh and low side process tubes.ImportantRemove piercing va lves af ter charg ing. Un it iscritically charged.ImportantPurge system wi th nitroge n wh ile brazing toprevent build u p of co pper oxide in therefrigeration system.Part Number 80-01111-9 7/10 187