Component Check ProceduresMain FuseFUNCTIONThe control board fuse stops ice machine operation ifelectrical components fail causing high amp draw.SPECIFICATIONS• QM20/QM30The main fuse is 250 Volt, 8 amp.• QM45/SM50/Q130/Q170/Q210/Q270The main fuse is 250 Volt, 10 amp.! WarningHigh (line) voltage is applied to the control b oardat all ti mes. R emoving th e con trol boa rd fuse ormoving the toggle switch to OFF will not removethe power supplied to the control board.CHECK PROCEDURE1. If the bin switch light is on with the ice damperclosed, the fuse is good.! WarningDisconnect electrical power to the emachine before proceeding.ntire ice2. Remove the fuse. Check the resistance acrossthe fuse with an ohmmeter.ReadingOpen (OL)Closed (O)ResultReplace fuseFuse is goodPart Number 80-01111-9 7/10 159