FindingsThe inlet of the harvestvalve is cool enough totouch and the compressordischarge line is hot.Cool & HotThe inlet of the harvestvalve is hot and approachesthe temperature of a hotcompressor discharge line.Hot & HotBoth the inlet of the harvestvalve and the compressordischarge line are coolenough to touch.Cool & CoolCommentsThis is normal as thedischarge line shouldalways be too hot to touchand the harvest valve inlet,although too hot to touchduring harvest, should becool enough to touch after 5minutes into the freezecycle.This is an indicationsomething is wrong, as theharvest valve inlet did notcool down during the freezecycle. If the compressordome is also entirely hot,the problem is not a harvestvalve leaking, but rathersomething causing thecompressor (and the entireice machine) to get hot.This is an indicationsomething is wrong, causingthe compressor dischargeline to be cool to the touch.This is not caused by aharvest valve leaking.5. Record your findings on the table.156 Part Number 80-01111-9 7/10