QM20/QM30DIAGNOSING AN ICE MACHINETHAT WILL NOT RUN! WarningHigh (line) voltage is applied to the co ntrol board(terminals #8 and #2 ) at all times. Removin gcontrol board fuse or moving the toggle switch toOFF wil l not remove the powe r supplied to th econtrol board.1. Verify primary voltage is supplied to ice machine.2. Verify that the fuse or circuit breaker is closed.3. Verify control board fuse is OK. If the power lightfunctions, the fuse is OK.4. Verify ICE/OFF/WASH toggle switch functionsproperly. A defective toggle switch may keep theice machine in the OFF mode.5. Verify the bin thermostat functions properly. Adefective bin thermostat can falsely indicate a fullbin of ice.6. Verify low DC voltage is properly grounded. LooseDC wire connections may intermittently stop theice machine.7. Replace the control board.8. Be sure steps 1-6 were followed thoroughly.Intermittent problems are not usually related tothe control board.134 Part Number 80-01111-9 7/10