Q130/Q170/Q210/Q270 Ice Machines Only(continued)Operational AnalysisHot Gas ValveDischarge Line Temp.Record freeze cycledischarge line temp at theend of freeze cycle.Final AnalysisEnter total number ofboxes checked ineach column.1The hot gas valveinlet isHOTandThe compressordischarge line isHOTDischarge linetemp 150°F(66°C) or higherat the end offreeze cycleHot Gas ValveLeaking2The hot gas valveinlet isCOOLandThe compressordischarge line isHOTDischarge linetemp 150°F(66°C) or higherat the end offreeze cycleLow On Charge-or-TXV Starving3The hot gas valveinlet isCOOLandThe compressordischarge line isCOOLDischarge linetemp less than150°F (66°C) atthe end of freezecycleTXV Flooding4The hot gas valveinlet isCOOLandThe compressordischarge line isHOTDischarge linetemp 150°F(66°C) or higherat the end offreeze cycleCompressorPart Number 80-01111-9 7/10 133