Discharge Line Temperature Above 150°F (66°C) atEnd of Freeze Cycle:Ice machines that are operating normally will haveconsistent maximum discharge line temperaturesabove 150°F (66°C).Verify the expansion valve sensing bulb is positionedand secured correctly.Discharge Line Temperature Below 150°F (66°C) atEnd of Freeze CycleIce machines that have a flooding expansion valve willhave a maximum discharge line temperature thatdecreases each cycle.Verify the expansion valve sensing bulb is 100%insulated and sealed airtight. Condenser air contactingan incorrectly insulated sensing bulb will causeoverfeeding of the expansion valve.Part Number 80-01111-9 7/10 127