Discharge Pressure High ChecklistImproper Installation• Refer to “Installation and Visual InspectionChecklist” on page 104.Restricted Condenser Air Flow• High inlet air temperature• Condenser discharge air re-circulation• Dirty condenser fins• Defective fan cycling control• Defective fan motorImproper Refrigerant Charge• Overcharged• Non-condensable in system• Wrong type of refrigerantOther• Non-<strong>Manitowoc</strong> components in system• High side refrigerant lines/component• Restricted (before mid-condenser)Freeze Cycle Discharge Pressure Low ChecklistImproper Installation• Refer to “Installation and Visual InspectionChecklist” on page 104.Improper Refrigerant Charge• Undercharged• Wrong type of refrigerantOther• Non-<strong>Manitowoc</strong> components in system• High side refrigerant lines/component restricted(before mid-condenser)• Defective fan cycle controlNOTE: Do not limit your diagnosis to only the itemslisted in the checklists.116 Part Number 80-01111-9 7/10