Safety Limit #2Harvest time exceeds 3.5 minutes for 6Consecutive harvest cycles.Possible Cause ChecklistImproper installation• Refer to “Installation and Visual InspectionChecklist” on page 104.Water System• Water area (evaporator) dirty• Dirty/defective water dump valve• Vent tube not installed on water outlet drain• Water freezing behind evaporator• Plastic extrusions and gaskets not securelymounted to the evaporator• Low water pressure (20 psig min.)• Loss of water from sump area• Clogged water distribution tube• Dirty/defective float valve• Defective water pumpElectrical system• Ice thickness probe out of adjustment• Ice thickness probe dirty• Bin switch defective• Premature harvestRefrigeration system• Non-<strong>Manitowoc</strong> components• Improper refrigerant charge• Defective hot gas valve• TXV flooding (check bulb mounting)• Defective fan cycling control114 Part Number 80-01111-9 7/10