12.07.2015 Views

Transducer TC2122 - Teledyne Reson

Transducer TC2122 - Teledyne Reson

Transducer TC2122 - Teledyne Reson

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Transducer</strong> <strong>TC2122</strong>Dual-Frequency Survey Echosounder <strong>Transducer</strong><strong>TC2122</strong>• Narrow beams• High acoustical performance• Compact designModel <strong>TC2122</strong> is a 33kHz and 200kHz dual frequency transducer idealfor navigation and hydrographic echosounder systems. The transducer hasexcellent piezoceramic elements which will ensure the highest reliability andquality in echosounding. The transducer will fit ATLAS SW 60/28/6029housing and RESON steel housings.• Compatible with ATLASSW60/28/6029 housing.• Electrical compatible withmost 33kHz and 200kHzechosounders.TECHNICAL SPECIFICATIONS<strong>Reson</strong>ant Frequency:33kHz ±2kHz 200kHz ±5kHzTransmitting sensitivity: 168dB ±3dB at 33KHz 174dB ±3dB at 200KHz (re 1µPa/V at 1m)Receiving Sensitivity:-177dB ±3dB at 33KHz -187dB ±3dB at 200KHz (re 1µPa/V)Impedance:80ohm ±24ohm at 33kHz and 200kHzBeam width:22°±2° at 33KHz 9,5°±1° at 200kHzBeam shape:ConicalMax input power:1000W at 33kHz 450W at 200kHz (at 1% duty cycle)Operating depth:30mSurvival depth:50mOperating temperature range: -2°C to +35°CStorage temperature range: -30°C to +50°CWeight in air,with cable:5kgHousing:PVCCable (length and type):33m FALMAT Type FM088095-7, 4x1 (2 x twisted pair) PUR Jacket,WATER BLOCK, Kevlar Braid 800lbs breaking strength (O.D. 11mm) - pigtail


<strong>Transducer</strong> <strong>TC2122</strong>Dual-Frequency Survey Echosounder <strong>Transducer</strong>Typical graphs 200kHz<strong>TC2122</strong> Transmitting Directional ResponseHorizontal Directivity Pattern-184Receiving Receiving Sensitivity Response[dB re 1V/µPa[dB@ 1m]re 1V/µPa @ 1m]-30 o -20 o -10 o 0 o 10 o 20 o 30 o0 dB-3 dB-10 dB-186-188-190-192-20 dB-194-196-30 dB-198190 192.5 195 197.5 200 202.5 205 207.5 210 212.5 215 217.5 220 222.5 225 227.5 230Frequency [kHz]-40 dB200.00 kHz174Transmitting Transmitting Sensitivity Response [dB re 1µPa/V [dB@ re 1m] 1µPa/V @ 1m]200Impedance<strong>TC2122</strong> Impedance Summary17317217115010050170169168167166190 192.5 195 197.5 200 202.5 205 207.5 210 212.5 215 217.5 220 222.5 225 227.5 230Frequency [kHz]Ω0-50-100 ResistanceReactanceImpedance-150190 192.5 195 197.5 200 202.5 205 207.5 210 212.5 215 217.5 220 222.5 225 227.5 230Frequency [kHz]


<strong>Transducer</strong> <strong>TC2122</strong>Dual-Frequency Survey Echosounder <strong>Transducer</strong>Outline DimensionsRESON reserves the right to change specifications without notice. © 2006 RESON A/SFor Acoustical Measurement Accuracy please refer to www.reson.com or contact sales.RESON A/SDenmarkTel: +45 4738 0022E-mail: reson@reson.comRESON GmbHGermanyTel: +49 431 720 7180E-mail: reson@reson-gmbh.deRESON Inc.USATel: +1 805 964-6260E-mail: sales@reson.comRESONB.V.The NetherlandsTel: +31 (0) 10 245 1500E-mail: info@reson.nlRESON Offshore Ltd.United KingdomTel: +44 1224 709 900E-mail: sales@reson.co.ukRESON (Pte.) Ltd.SingaporeTel: +65 6725 9851E-mail: sales@reson.comVersion: B089 090107 / A4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!