PSC9713European Refrigeration Controls CatalogueCatalog Section 3Product Bulletin <strong>F63</strong>Issue 9705<strong>Series</strong> <strong>F63</strong>Liquid Level Float Switches for Open or Closed TanksI ntroductionThe <strong>F63</strong> is a liquid level float switch for use inopen or closed tanks where a desired liquidlevel has to be maintained. They can be used inopen or closed tanks and installations handlingwater, swimming pool water, sea water, brine,ethylene glycol or other liquids not harmful tothe specified materials. The switches haveSPDT contacts and can be wired to close onecircuit and open a second circuit when the liquidlevel rises above or falls below the requiredlevel. The switch maintains the liquid levelwithin (approx.) 13 mm.There are three different types available. Thephosphor bronze bellows version for use inapplications where the liquid is not corrosive tophosphor bronze. The stainless steel bellowsversion for use in environments like coolingtowers ( water with high calcium content) and acomplete stainless steel AISI 316L version. Allmaterials in contact with the liquid are specifiedin the part “specifications”. At doubt about theliquid used with regards to these materials it isadvised to contact the liquid supplier. Thesefloat switches should not be used for liquidslighter than water ( density less than 0.95kg/dm 3 ).<strong>F63</strong> Float SwitchFeature and Benefitsq Solid polycarbonate floatq Vapour tight IP 67 enclosureq Convenient wiring terminalsq Three modelsWill not accumulate liquid and providesdependable level detection.Allows for use in indoor and outdoor as wellas low temperature applicationsMakes wiring convenient and easilyaccessible.For many different types of liquids© 1997 Johnson Controls Inc. Catalogue Section 3Order No. PD-<strong>F63</strong>-E


2<strong>F63</strong>Issue 9705N oteThese controls are designed for use onlyas operating controls. Where an operatingcontrol failure would result in personalinjury or loss of property, it is theresponsibility of the installer to adddevices or systems that protect against, orwarn of, control failure.Suggested circuits for controlling “Fill” and“Dump” levels with larger differences betweenminimum and maximum levels.DumpF H! CautionDo not use with hazardous fluids or inhazardous atmosphere.FillF LI nstallationTo allow the switch to respond to changes inthe liquid levels, the float must not touch theside of the tank or any other obstructions.Install the <strong>F63</strong> in a 1” threaded horizontal tankopening ( see “ specifications” ) at the heightwhere the liquid level is to be maintained.Position the switch with the arrow on theenclosure pointing “up” for proper operation. Aspecial vapour proof PG-16 nipple for cableinlet is delivered with the control. This nipplehas to be used to keep the control vapour tight.FillR S TFig. 3L 3 3NF HR A1 1RpumpF LM3 ~PUMPFig. 4R A= Aux. contact pump relayFig. 1L2 2W iring 3 2DumpR S TR AF H1 1F L1Fig. 2Contact function1 to 2 closes on liquid level rise.M3 ~PUMPNFig. 5RpumpCatalogue Section 3© 1997 Johnson Controls Inc.Order No. PD-<strong>F63</strong>-E


<strong>F63</strong>Issue 9705A djustmentAll <strong>F63</strong> versions are factory set and sealed. Nofield adjustments are required.Type number selection tableRepair and replacementRepair is not possible. In case of an improperlyfunctioning control, please check with yournearest supplier. When contacting the supplierfor a replacement you should state thetype/model number of the control. This numbercan be found on the data plate or cover label.3Ordernumber<strong>F63</strong>BT-9101<strong>F63</strong>BT-9102<strong>F63</strong>BT-9200TypeBrass bodyPhosphor bronze bellowsBrass bodyStainless steel bellowsStainless steel bodyStainless steel bellowsUsed forwater, sea water, ethylene glycol, brinecooling tower applicationsswimming poolsD imensions115C601005521529 17Ø25BABody -9200 models452530Fig. 6A . Cable inlet hole ø 22.3 mm Vapour proof PG-16 nippleBC (HEX)<strong>F63</strong>BT-9101 1-11½ NPT 34 mm<strong>F63</strong>BT-9102 1-11½ NPT 34 mm<strong>F63</strong>BT-9200 R1” DIN 2999 (ISO R7) 45 mm© 1997 Johnson Controls Inc. Catalogue Section 3Order No. PD-<strong>F63</strong>-E


4<strong>F63</strong>Issue 9705S pecificationsType number <strong>F63</strong>BT-9101 <strong>F63</strong>BT-9102 <strong>F63</strong>BT-9200Pipe connection 1-11½ NPT 1-11½ NPT R1" DIN 2999(ISO R7)Max liquid pressure 10 bar 10 bar 10 barMax. liquid temperature* 100°C 100°C 100°CMin. liquid temperature** -30°C -30°C -30°CMax. ambient temp.* +55°C +55°C +55°CMin. ambient temp.** -40°C -40°C -40°CAmbient humidity Vapour proof Vapour proof Vapour proofContact type SPDT snap-actingswitchSPDT snap-actingswitchSPDT snap-actingswitchElectrical rating 15(8) A 230Vac 15(8) A 230Vac 15(8) A 230VacWiring connections screw terminals1 up to 2.5mm 2 screw terminals1 up to 2.5mm 2 screw terminals1 up to 2.5mm 2Maintains liquid level 13 mmwithin(approx)13 mm 13 mmEnclosure IP67 IP67 IP67Materials cover / case Polycarbonate Polycarbonate PolycarbonateMaterials in contact with liquidfloat Polycarbonate Polycarbonate Polycarbonatebellows phosphor bronzeCuSn 6stainless steelAISI 316L DIN1.4404stainless steelAISI 316L DIN1.4404rod bronzeASTM B140-alloy 316bronzeASTM B140-alloy 316stainless steelAISI 316 DIN1.4401body brass ASTM B584alloy C84400brass ASTM B584alloy C84400stainless steelAISI 316 DIN1.4401washer brass ASTM B36alloy C23000brass ASTM B36alloy C23000stainless steelAISI 316 DIN1.4401silver solder L-Ag45 L-Ag45 nonesoftsolder L-SnAg5 L-SnAg5 noneShipping weight individual pack 0.85 kg 0.85 kg 1.0 kgoverbox ( 7 pcs ) 7 kg 7 kg -Vibration acc.to DIN 89011 Kennlinie I* The max. liquid temperature of 100°C is at 20°C ambient. At higher ambient temperatures the max. allowed liquid temp. becomeslower. The temperature of the electrical switch inside should not exceed 70°C.** The low liquid temperature combined with a low ambient temp.should not lead to freezing of the liquid inside the body / bellows.Please observe the liquid freezing point.The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyondthese specifications, consult the local Johnson Controls office or representative. Johnson Controls shall not be liable for damagesresulting from misapplication or misuse of its products.Johnson Controls International, Inc.Headquarters:Milwaukee, WI, USAEuropean Headquarters: Westendhof 8, 45143 Essen, GermanyEuropean Factories: Lomagna (Italy), Leeuwarden (The Netherlands) and Essen (Germany)Branch Offices:Principal European Cities.This document is subject to changePrinted in EuropeCatalogue Section 3© 1997 Johnson Controls Inc.Order No. PD-<strong>F63</strong>-E