Bulletin A-180b - Brasch

Bulletin A-180b - Brasch Bulletin A-180b - Brasch

braschmfg.com
from braschmfg.com More from this publisher

ContentsProductPageWall Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 2Ceiling Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 4Baseboard Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 6Cabinet Unit Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... 7 - 8Washdown Unit Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 12Hazardous Location Unit Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 - 18Architectural Electric Convectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 - 22


BRASCH Architectural Forced Air WALL HeatersDecorator Designed for Functional Beauty and VersatilityRugged Grille: Heavy dark brown 18 gauge steel grille.Richly Styled Grille: Grille is highlighted by a 14-gauge anodized extruded aluminumframe.Electric Element: Steel sheath with plate heat exchanger.Fan Delay Switch: Allows fan to continue to run for a short period after thermostat issatisfied to expel warm air from inside heater, also delays fan on start up to insuredelivery of heated air.Unique Vane Axial Fan Wheel draws in large volumes of air then quietly dischargesheated air downward into room.Tamper Resistant Thermostat and Disconnect Switch accessible through grille.SpecificationsModel Number Watts Volts WeightBWH7512 750 120 22 lb.BWH1012 1000 120 22 lb.BWH1512 1500 120 26 lb.BWH4020 4000 208 29 lb.BWH4820 4800 208 29 lb.BWH1524 1500/1125 240/208 26 lb.BWH2024 2000/1500 240/208 27 lb.BWH3024 3000/2250 240/208 29 lb.BWH4024 4000/3000 240/208 29 lb.BWH4824 4800 240 29 lb.BWH1527 1500 277 26 lb.BWH2027 2000 277 27 lb.BWH3027 3000 277 29 lb.BWH4027 4000 277 29 lb.BWH4827 4800 277 29 lb.Field Installed AccessoriesModel Number Description WeightBox 3310 Rough-in Box Only (for advance installation) 10 lb.3320EX33 Surface Mounting Adapter 1 lb.3320EX16 2" Semi-recess Sleeve 1 lb.Factory Installed AccessoriesSuffixDescriptionRDay Night RelayHD16 Ga. Steel Heavy Duty GrillArchitectural QualityWall Mounted■ Built-in disconnect switch■ Built-in tamper resistant thermostat■ Richly styled, rugged grille■ Whisper-quiet sound level■ Fan delay■ 1-Year element limited warranty■ U.L. listed■ CSA listedTypical Specifications<strong>Brasch</strong> Heavy-Duty Forced Air Heaters shall beconstructed of a heavy 18 gauge steel housingwith an extruded aluminum frame.The rough-indimensions are 19-5/16" high x 14-3/16" wide x4" deep.The units shall be available in ratingsfrom 750 to 1500 watts at 120 and 1500 to 4800watts at 240, 208 and 277 volts.The heaters shallhave a low-speed 600 RPM, 4-pole motor whichdrives a vane axial blower to deliver a quiet 175CFM of down flow air. The heating elementshall be of the sealed tubular type with large,parallel steel fins for quick heat transfer. Unitshall have as standard, a thermal overload cutofffor added safety, fan delay switch and a builtintamperproof thermostat which shall becalibrated to provide a range of 55°F. to 85°F.and manual disconnect switch.Optional accessories shall include a surfacemounting adapter, day-night relays. All heatersshall be listed by Underwriter's Laboratories, Inc.The heating element shall be supplied with amanufacturer’s 1-year limited warranty.ELECTRIC HEATING PRODUCTS 1


Dimensions2 BRASCH MANUFACTURING COMPANY, INC.


BRASCH CEILING HeatersRecess • Surface • T-BarVersatile applicationLarge volume of comfortably warm air is produced by a whisper-quiet heater. Idealfor residential, commercial and industrial locations where wall and floorapplications are not feasible.Quiet OperationBecause of the extremely quiet operation, the BCH may be used in restaurants,nursing homes, schools and lobbies. They draw in large volumes of air anddischarge heated air downward into the needed areas. These heaters feature thevane axial fan that has proven to be successful in other products.SpecificationsModel Number Watts Volts WeightBCH1512 1500 120 22 lb.BCH4020 4000 208 22 lb.BCH4820 4800 208 22 lb.BCH2024 2000/1500 240/208 22 lb.BCH3024 3000/2250 240/208 22 lb.BCH4024 4000/3000 240/208 22 lb.BCH4824 4800 240 22 lb.BCH2027 2000 277 22 lb.BCH3027 3000 277 22 lb.BCH4027 4000 277 22 lb.BCH4827 4800 277 22 lb.Field Installed AccessoriesModel Number Description WeightBox 3310 Rough-in Box Only (for advance installation) 10 lb.3380 EX33 Surface Mounting Box 1 lb.TB 3380 T-Bar Mounting Box 7 lb.Other Standard Features Include:■ Neutral ceiling white, rust resistantfinish to blend in with most anyceiling color or decor. Grille is shallowin design to look unobtrusive.■ Automatic fan delay. Whenthermostat is satisfied, the fancontinues to run momentarily untilall heated air is discharged to insureefficiency.■ Disconnect switch.■ Totally enclosed steel fin sheathelement for safety and long life.■ Mounting ApplicationsRecess (Standard)Surface (3380 EX33 Kit)2x2 T-Bar (TB3380 Kit)Typical Specifications<strong>Brasch</strong> Electric Forced Air Heaters shall beconstructed of a heavy gauge steel housing.The rough-in dimensions are 19-5/16" high x14-3/16" wide x 4" deep. The finish shall bebaked-on enamel paint in Ceiling White color.The units shall be available in ratings from1500 through 4800 watts.The heaters shall have a low speed 600RPM motor which drives a vane axial blower todeliver a quiet 175 CFM of down flow air. Theheating element shall be of the sealed tubulartype with large, parallel steel fins for quick heattransfer. Unit shall have as standard a thermaloverload cutoff for added safety.All heaters shall be listed by Underwriters'Laboratories, Incorporated. The heatingelement shall be supplied with amanufacturer's 1 year limited warranty.ELECTRIC HEATING PRODUCTS 3


Dimensions4 BRASCH MANUFACTURING COMPANY, INC.


BRASCH BASEBOARD HeatersSpecificationsModel Number Volts Watts Heater LengthB24-375A 120 375 24"B24-375B 208 375 24"B24-375C 240/208 375/281 24"B24-375D 277/240 375/281 24"B28-500A 120 500 28"B28-500B 208 500 28"B28-500C 240/208 500/375 28"B28-500D 277/240 500/375 28"B36-600A 120 600 36"B36-600B 208 600 36"B36-600C 240/208 600/450 36"B36-600D 277/240 600/450 36"B40-750A 120 750 40"B40-750B 208 750 40"B40-750C 240/208 750/563 40"B40-750D 277/240 750/563 40"B48-1000A 120 1000 48"B48-1000B 208 1000 48"B48-1000C 240/208 1000/750 48"B48-1000D 277/240 1000/750 48"B48-750D 277 750 48"B60-1250A 120 1250 60"B60-1250B 208 1250 60"B60-1250C 240/208 1250/938 60"B60-1250D 277/240 1250/938 60"B60-938D 277 938 60"B72-1500A 120 1500 72"B72-1500B 208 1500 72"B72-1500C 240/208 1500/1125 72"B72-1500D 277/240 1500/1125 72"B72-1125D 277 1125 72"B84-1750B 208 1750 84"B84-1750C 240/208 1750/1313 84"B84-1750D 277/240 1750/1313 84"B84-1313D 277 1313 84"B96-2000B 208 2000 96"B96-2000C 240/208 2000/1500 96"B96-2000D 277/240 2000/1500 96"B96-1500D 277 1500 96"B120-2500B 208 2500 120"B120-2500C 240/208 2500/1875 120"B120-2500D 277/240 2500/1875 120"B120-1875D 277 1875 120"Stainless Steel ElementRod with Aluminum Fins■ All heaters are constructed of rollformed steel and painted with apowder coat textured finish foroutstanding durability and attractiveappearance. <strong>Brasch</strong> Baseboards areavailable in both ivory and white - addsuffix w to model number for white.■ Quick connect cable clamps arelocated in right and left junction boxesto restrain incoming field wiringwithout the need for additionalhardware.■ All baseboards are only 6" high andextend 2 1/2" from the wall makingthe <strong>Brasch</strong> Baseboard heater one ofthe most compact baseboard heaterson the market.■ All baseboards are constructed with afull length wireway along the back ofthe heater. An optional wireway covercan be ordered when specificationcalls for an enclosed wireway.■ Integral thermostats use the junctionbox cover plate on the baseboardheater. This eliminates the need forstocking different colors of built-inthermostats.■ A 6" ground lead wire is provided inboth right and left junction boxesallowing for easier ground connection.■ The <strong>Brasch</strong> Baseboard has long-lastingstainless steel element rod with itsaluminum chimney designed fins. Thefins are mechanically staked to theelement rod to allow excellent transferand dissipation of heat from the heaterinto the room. By using a stainless steelrod, the hum associated with othermodels on the market is eliminated.■ An over-temperature thermal limitextends the entire length of the heatedarea to serve as a safety device in case ofan air flow blockage in front of heater.■ All units have 20 gauge junction boxesat both ends of the heater. The frontand back of the heater are constructedof 22 gauge roll formed steel.■ The heater can be mounted to thewall by using key hole knockoutsevery 4" at the back of the heater.ELECTRIC HEATING PRODUCTS 5


DimensionsBlank SectionsBaseboard Ivory WhiteLength Model # Model #24" BBS024 BBS024W28" BBS028 BBS028W36" BBS036 BBS036W40" BBS040 BBS040W48" BBS048 BBS048W60" BBS060 BBS060W72" BBS072 BBS072W84" BBS084 BBS084W96" BBS096 BBS096W120" BBS120 BBS120WItem Model Number Description WeightDS Disconnect Switch-IvoryDisconnect Switch DSW Disconnect Switch-White 1 lb.CSIvory Corner SectionCorner Sections CSW White Corner Section 1 lb.JK1" Ivory Joiner KitJoiner Kits JKW 1" White Joiner Kit 0.25 lb.6" Blank Section LVRS 6" Ivory Relay Section(Relay Not Included) LVRSW 6" White Relay Section 1.5 lb.Receptacle Section BDR115 Ivory - 15amp, 120 VAC(Baseboard Mounted) BDR115W White - 15amp, 120 VAC 0.25 lb.Receptacle Section DR115 Ivory - 15amp, 120 VAC(Mtd. in 6" Blank Section) DR115W White - 15amp, 120 VAC 2 lb.Transfer Switch SR120 Ivory - 16amp, 120 VAC(Mtd. in 6" Blank Section) SR120W White - 16amp, 120 VAC 2 lb.Transfer Switch SR220 Ivory - 16amp, 240 VAC(Mtd. in 6" Blank Section) SR220W White - 16amp, 240 VAC 2 lb.Wireway Adapters (to enclose wireway when specified)Model Number Baseboard Length Adapter Length WeightWWA01 24" 20" 1 lb.WWA02 28" 24" 1.5 lb.WWA03 36" 32" 2 lb.WWA04 40" 36" 2.5 lb.WWA05 48" 44" 3 lb.WWA06 60" 56" 4 lb.WWA07 72" 68" 5 lb.WWA08 84" 80" 6 lb.WWA09 96" 92" 7 lb.WWA00 120" 116" 8 lb.Baseboard AccessoriesModel #TBS*TBS-TPTBD*TBD-TP* Used on all baseboard modelsDescriptionSPST-In-built22A/120-240V18A/277VSPST-In-built22A/120-240V18A/277 VTAMPERPROOFDPST-In-built22A/120-240V18A/277VDPST-In-built22A/120-240V18A/277VTAMPERPROOF6 BRASCH MANUFACTURING COMPANY, INC.


BRASCH Electrical CABINET UNIT HeatersThe <strong>Brasch</strong> Cabinet Unit Heater (BCUH) is ideal for commercial andinstitutional applications such as offices, stores, schools, churchesand entry ways.Standard units include a disconnect switch, built-in 24 volt thermostatand disposable air filters but the <strong>Brasch</strong> Cabinet Unit Heater can alsobe customized to meet your most demanding applications.All units have a beige powder coated finish over an 18 ga. steelhousing that is 9 1⁄2" deep and 25" high and are manufactured with steelsheathed finned tubular elements with full-length thermal protection.Controls• Choice of eight control options include, built-in or wall mountedthermostats (24 or 120 volt) with built-in control transformer,as needed.• Independently adjustable heat settings (high / low) and fan motorspeeds (1550 / 1400 rpm) are standard, except 480 volt units havea single fan speed.• Power interrupt options include either a circuit breaker ordisconnect switch, except only circuit breakers can be used onheaters that draw over 48 amps.• Optional summer fan switch.Mounting & Flow Configurations• Mounting options include surface, semi-recessed or fully-recessed;on walls or ceilings; and upright or inverted.• Air flow can be configured in any combination of intake and outputthrough the top, bottom or front. In addition, a duct collar canprovide expanded application and flexibility.Air Flow ConfigurationsABC(May be inverted)Bottom In / Top Out(Top In / Bottom Out)Bottom In / Front Out(Top In / Front Out)Front In / Top Out(Front In / Bottom Out)Standard ModelsDFront In / Front Out* = Factory wired for 3 phaseField convertible to single phase


Custom Models


BRASCH WASHDOWN UNIT Heatersfor Corrosion-Resistant ApplicationsPlated Inlet GrilleScroll - 304 Stainless SteelMounting Bracket -Easy-mount bracket foruse with field-installed hangeror optional mounting bracketsTotally Enclosed MotorStainless SteelDischarge GrilleAluminum Fan BladeElementThermostatThree-Position Switch(Heat - Fan - Off )Pilot Light (Heater Energized)Door InterlockDisconnection Switch (Optional)Control Components(24-volt Standard)Nema 4x Non-Metallic EnclosureRugged construction, stainless steelenclosure for use in wet* andcorrosive* atmospheres (nonhazardouslocations).*Refer to installation and application data forapplicable environments or consult factory.The BWUH unit heaters are electric unitheaters constructed for use in areasthat require washing or hosing ofequipment due to dirty or dustyindustrial environment in nonhazardouslocations. the totallyenclosedwatertight construction madewith corrosion-resistant material makethe BWUH Series ideal for industrialheating applications. The BWUH Seriesis made with all built-in controls andsafety temperature controls wired in anon-metallic Nema 4x control panelwith single-point power connections.ELECTRIC HEATING PRODUCTS 9


Standard Features:■ Up to 48 KW■ Up to 600 Volts■ Disconnect switch with enclosureinterlock■ Heavy-duty 304 stainless steelshroud■ Nema 4x non-metallic control panel■ 24-volt transformer and control circuit■ 3-position switch (off - heat - fan)■ Capillary thermostat with stainlesssteel sensor■ Automatic reset thermal cutout■ Totally enclosed UL Listed motor■ Pilot light (power on indicator)■ Chrome-plated finned tubular element■ Control panel on bottom of unit forease in installation and service■ Single-point power connection■ Meets all UL, NEC, and OSHArequirements (when installed asdirected)■ Corrosion-resistant in high humidityand water-saturated areas (for areaswhere corrosion-resistance is neededin non-hazardous areas, contactfactory for heater applications andoptional materials).Options■ Teflon anodized aluminum fan blade(3-30 kw only)■ Remote 24-volt thermostat■ Stainless steel wall/ceiling mountingbracket (3.3-15 kw)■ Cast iron painted mounting bracketavailable on all units for wall/ceiling orpipe mounting■ Hanging bracket for use withthreaded rodSample SpecificationThe electric unit heater shall be <strong>Brasch</strong>BWUH Series rated for washdownapplications and shall include built-incontrols. Heaters shall be UL Listedassemblies containing all limits andcontrols as required by ULspecifications. Controls shall be housedin a Nema 4x non-metallic controlenclosure fixed to bottom of unitheater. The control enclosure will openfrom bottom for ease of installationand service. The control enclosure willinclude contactors, 24-volt transformer,fusing (NEC required) pilot light (poweron), thermostat and 3-position switch(heat - off - fan).The heater scroll will be 16 gauge 304stainless steel with 304 stainless steeloutlet louvre. The inlet grille will bechrome plated.The motor shall be totally enclosed,permanently lubricated, designed toresist moisture and corrosion, andfactory-wired to Nema 4x enclosure.Single point line voltage connectionavailable for 208, 240, 277, 480, and 600volt service.Door interlock disconnect on Nema 4xcontrol enclosure shall be factoryinstalled and wired.Heavy-duty heating elements factorywired and sealed for washdownapplication shall be plated forcorrosion resistance.10 BRASCH MANUFACTURING COMPANY, INC.


Washdown Unit HeaterCatalog BTU Heater Standard Max. MotorNumber KW HR Volts Phase Control Amps Voltage HP RPMVoltageBWUH3.3-2081 3.3 11200 208 1 24 15.9 208 1/30 1550BWUH3.3-2083 3.3 11200 208 3 24 19.2 208 1/30 1550BWUH3.3-2401 3.3 11200 240 1 24 13.7 240 1/30 1550BWUH3.3-2403 3.3 11200 240 3 24 7.9 240 1/30 1550BWUH3.3-2771 3.3 11200 277 1 24 11.9 277 1/30 1550BWUH3.3-4803 3.3 11200 480 3 24 4.0 480 1/30 1550BWUH3.3-6003 3.3 11200 600 3 24 3.2 600 1/30 1550BWUH5.0-2081 5.0 17100 208 1 24 24.1 208 1/30 1550BWUH5.0-2083 5.0 17100 208 3 24 13.9 208 1/30 1550BWUH5.0-2401 5.0 17100 240 1 24 20.8 240 1/30 1550BWUH5.0-2403 5.0 17100 240 3 24 12.1 240 1/30 1550BWUH5.0-2771 5.0 17100 277 1 24 18.1 277 1/30 1550BWUH5.0-4803 5.0 17100 480 3 24 6.1 480 1/30 1550BWUH5.0-6003 5.0 17100 600 3 24 4.8 600 1/30 1550BWUH7.5-2081 7.5 25600 208 1 24 36.1 208 1/30 1550BWUH7.5-2083 7.5 25600 208 3 24 20.8 208 1/30 1550BWUH7.5-2401 7.5 25600 240 1 24 31.3 240 1/30 1550BWUH7.5-2403 7.5 25600 240 3 24 18.0 240 1/30 1550BWUH7.5-2771 7.5 25600 277 1 24 27.0 277 1/30 1550BWUH7.5-4803 7.5 25600 480 3 24 9.0 480 1/30 1550BWUH7.5-6003 7.5 25600 600 3 24 7.2 600 1/30 1550BWUH10-2081 10.0 34130 208 1 24 47.8 208 1/30 1550BWUH10-2083 10.0 34130 208 3 24 27.7 208 1/30 1550BWUH10-2041 10.0 34130 240 1 24 41.2 240 1/30 1550BWUH10-2403 10.0 34130 240 3 24 24.1 240 1/30 1550BWUH10-2771 10.0 34130 277 1 24 36.1 277 1/30 1550BWUH10-4803 10.0 34130 480 3 24 12.1 480 1/30 1550BWUH10-6003 10.0 34130 600 3 24 9.6 600 1/30 1550BWUH15-2081 15.0 51200 208 1 24 72.1 208 1/30 1550BWUH15-2083 15.0 51200 208 3 24 41.7 208 1/30 1550BWUH15-2041 15.0 51200 240 1 24 62.5 240 1/30 1550BWUH15-2403 15.0 51200 240 3 24 36.1 240 1/30 1550BWUH15-4803 15.0 51200 480 3 24 18.1 480 1/30 1550BWUH15-6003 15.0 51200 600 3 24 14.5 600 1/30 1550BWUH20-2083 20.0 68260 208 3 24 55.6 208 1/3 1625BWUH20-2403 20.0 68260 240 3 24 48.2 240 1/3 1625BWUH20-4803 20.0 68260 480 3 24 24.1 480 1/3 1625BWUH20-6003 20.0 68260 600 3 24 19.3 600 1/3 1625BWUH25-2083 25.0 85325 208 3 24 69.5 208 1/3 1625BWUH25-2403 25.0 85325 240 3 24 60.2 240 1/3 1625BWUH25-4803 25.0 85325 480 3 24 30.1 480 1/3 1625BWUH25-6003 25.0 85325 600 3 24 24.1 600 1/3 1625BWUH30-2083 30.0 102390 208 3 24 83.9 208 1/3 1625BWUH30-2403 30.0 102390 240 3 24 72.3 240 1/3 1625BWUH30-4803 30.0 102390 480 3 24 36.1 480 1/3 1625BWUH30-6003 30.0 102390 600 3 24 28.9 600 1/3 1625BWUH40-4803 40.0 136520 480 3 24 46.2 480 1/3 1625BWUH40-6003 40.0 136520 600 3 24 38.5 600 1/3 1625BWUH48-4803 48.0 163824 480 3 24 57.8 480 1/3 1625BWUH48-6003 48.0 163824 600 3 24 46.2 600 1/3 1625ELECTRIC HEATING PRODUCTS 11


CFM RPM F° Temp Air Throw Rec. Mtg. MountingKW Outlet Outlet Rise Outlet Ft. Height/Ft. Weight Bracket3.3 400 500 26 20 6 58 A55205.0 400 500 40 20 6 58 A55207.5 400 500 60 20 6 58 A552010.0 700 660 45 28 6 64 A552015.0 700 660 45 28 6 64 A552020.0 1400 1000 45 35 6 158 W555025.0 1400 1000 56 35 6 158 W555030.0 1400 1000 68 35 6 158 W555040.0 1800 1000 70 42 6 193 W555048.0 1800 1000 84 42 6 193 W5550HGAECDimension DataBFigure 1Figure 3DFFigure 2HeaterSize A B C D E F G H3-7.5 12 18 19.75 15.25 16.25 6 ft. 8.00 6.0010-15 14 19 21.75 15.25 18.00 6 ft. 8.00 6.0020-30 16 27 28.75 19.50 17.50 6 ft. 15.50 4.5040-48 18 31 30.75 19.50 19.50 6 ft. 21.75 2.75Mounting Bracket KitsIdeal for use in buildingsthat have substantial walls.Arm (only) can be bolteddirectly to structure steel.WALL BRACKETMOUNTING ARMSimple and economical ifadequate overheadstructure exists. Requires1/2" pipe, cut and threaded(not supplied).ROOF OROVERHEADSTRUCTUREParticularly useful inbuildings withinsufficient strengthto use other type ofmounts. Requires 31/2" pipe (4" O.D. -not supplied).COLUMN STABILIZINGCOMPONENTSMOUNTINGBRACKETATTACHMENTASSY.3 1/2" SCHEDULE 40(PIPE) (NOT SUPPLIED)1/2" PIPE(NOT SUPPLIED)BASE ASSEMBLYA55203.3-15 kw onlyWALL OR STRUCTUREWMK HMK PMKOptional - Wall Mounted ThermostatRaintight Industrial ThermostatThe T109 series of controls is intended foruse in harsh environments. They toleratecontinuous spraying with water, highhumidity, airborne contaminates andmoderately corrosive conditions. The nickelplated sensing bulb is attached directly tothe bottom of the case where it is shieldedfrom damage or accumulators of insulatingparticles. The molded Noryl case is sealedat the cover with a neoprene gasket andthe adjusting knob opening is closed witha lubricated 0 ring. UnderwritersLaboratories has tested the T109 and foundit meets the requirement for NEMA 4xenclosures.High levels of accuracy and sensitivity areprovided by the T109. Switching is done byheavy duty, precision, snap action switches.Setting is accomplished by rotating theadjusting knob. The dial face is printedwith large contrasting numbers and letterson a lustrous background for goodvisibility. Force and motion for switchactuation are provided by changes intemperature expanding or contracting thefluid contained with the sensing bulb andtransmitted hydraulically and through anappropriate linkage to the switch operator.Color coding clearly identifies the functionof each conductor.SwitchModel Controls Action OperationTA109 Heating SPST Opens circuiton temp riseTD109 Heating, 2pole 2 SPST Opens twoswitches ontemp. riseThe T109 is available with the followingcharacteristics: Range 40 - 100°F Differential: 2.5°FElectrical Ratings:120VAC 240VAC 277VACFull Load 16.0A 12.0A 10.0ALocked Rotor 80.0A 60.0A 50.0ANon-inductive 24.0A 25.0A 22.0APilot Duty 125VA 125VA 125VA12 BRASCH MANUFACTURING COMPANY, INC.


BRASCH HAZARDOUS LOCATION HeatersExplosion Proof Electric HeaterPressure Relief ValveRated at 200 PSIEpoxy Coated14 Ga. Cold Rolled Steel CabinetSpiral Aluminum FinnedTubular Steel Heat Exchanger Core,Liquid Filled Operation14 Ga. SteelAdjustable Louverswith Minimum Position Stops24V Control CircuitTransformerCast Aluminum Control Enclosurewith Oversized OpeningHeavy Duty LoadCarrying ContactorEtched Aluminum Data PlatesRiveted to CaseBuilt-inThermostat 45-90°F (optional)Copper SheathedImmersion TypeHeating Element■ Liquid to air heat exchanger with lowwatt density heating elements inethylene glycol solution that providesfreeze protection to -45°C.■ Ball bearing permanently lubricatedexplosion proof motor. Chromeplated guard meets OSHArequirements.■ Heavy-duty control contactor with 24Volt control circuit provided on allmodels.CAUTIONBefore installing and operating heatersconfirm location, classification andproperties of flammable vapors, liquids,gases, dusts and fibers which may bepresent. Each room, section or areashould be considered individually.For further information consult NationalElectric Code and National Fire PreventionAssociation (ANSI) standards. All modelsconform to OSHA requirements whenmounted at any height.For Class I, Group D,Divisions 1 & 2 and Class II,Groups E, F and G,Divisions 1 & 2ELECTRIC HEATING PRODUCTS 13


BHUH FeaturesDesigned for rugged industrialapplications in hazardous locationswhere the possibility of explosion orfire exists due to the presence ofcertain flammable gases, vapors,powdered metals or dusts.■ Permanently sealed, liquid to air,finned tube heat exchanger core.■ Ethylene Glycol to water mixtureused a heat transfer fluid in theheater core, providing -45°C, (-49°F)freeze damage protection.■ High-performance electric motordriven fan blows air across finnedtubes to effect uniform heat transferand area heat distribution.■ Automatic Reset capillary type highlimit provides high temperatureregulation and is rated for 100,000cycles of service.■ Stainless steel and aluminumpressure relief valve for overpressurecondition.■ 14 Ga. steel cabinet epoxy paintfinish contains heater core, motorand fan assembly.■ Narrow gap safety fan guard shieldsall moving parts.■ Adjustable louvers allow directionalcontrol of air.■ Copper conductor wires enclosed inrigid metal conduits carry allelectrical power.(Box lugs furnished for fieldconnections within an approvedenclosure)Abbreviated descriptions of UL classes,groups and divisions. Before selectingany heater for a particular application,refer to Article 500 as well as otherstandards referenced in the NationalElectric Code.Class I: Equipment does not havesurface operating temperature inexcess of the ignition temperature ofthe specific gas or vapor.Class II: Equipment does not havesurface temperature greater than theignition temperature of the specifieddust.Group D: Atmospheres such as butnot limited to acetone, alcohol,gasoline, lacquer solvent vapors,natural gas, propane or other gases orvapors of equivalent hazard.Group E: Atmospheres containingcombustible metal dust regardless ofresistivity, or other combustible dust ofsimilar hazard characteristics havingresistivity of less than 10° OHM-Centimeter.Group F: Atmospheres containingcarbon black, charcoal, coal or cokedust.Group G: Atmospheres containingcombustible dust having resistivity of10° OHM-Centimeter or greater.Division I: A location in whichignitable concentrations of flammablematerial exist under normal operatingconditions.Division II: Locations in whichflammable materials will normally beconfined within closed containers andescape only in the case of accidentalrupture, breakdown or duringmaintenance operations. Anyequipment approved for Division I isautomatically also approved forDivision II.Built-in Hydraulic Thermostatoptional on all BHUH models■ Stainless steel bulb and capillary■ 125 VA pilot duty■ Used on 24 volt, 120 volt or 208-240volt line voltage control■ 60° to 90° temp range■ Adjustable from front of unit withscrewdriver.Hazardous LocationThermostat Wall MountedSpecifications■ TW161 Single Pole■ 22 Amps 125-277 Vac■ 3/4 HP 125 Val■ 1 1/2 HP 250-277 Vac■ 5 1/2" H x 5 1/2" W x 4 3/4" D■ Can be used for heating or coolingapplicationsInstallation Conditions1. Refer to owner's manual.2. The BHUH Series electric unitheaters have been listed by theUnderwriters Laboratories formaximum surface temperatures. Useonly in atmospheres having anignition temperature higher than165°C (T3B) for Class I operation and165°C (T3B) for Class II.3. Altitude restrictions - seespecification table.4. Heater must be installed inpermanently mounted uprightposition and connected to fixedpower supply.5. Do not operate in atmospherescorrosive to steel and aluminum.14 BRASCH MANUFACTURING COMPANY, INC.


SpecificationsBHUH Model A BHUH Model B BHUH Model CUL Capacities 3KW 10,236 BTU* 15KW 51, 180 BTUAvailable 5KW 17,060 10KW 34,120 BTU 20KW 68,240 BTU7.5KW 25,590 BTU25KW 85,300 BTUUL Listing Class I, Group D, Divisions 1 & 2Class II, Groups E, F & G, Divisions 1 & 2UL Temperature CodeClass I: T3B 165°C (329°F)Class II: T3B 165°C (329°F)AIR CFM@70°F, (21°C) 580 1500 2450FPM 1000 1600 2000Air Temp, Rise 3KW 16.3°F* 10KW 21.0°F 15KW 19.0°F5KW 27.2°F20KW 25.5°F7.5KW 40.8°F25KW 32.3°FHorizontal Throw 24 ft. 40 ft. 43 ft.Max. Mtg. Height from floor 8 ft. 10 ft. 13 ft.Max. Operational Altitude 7.5KW 5500 ft. 25KW 5500 ft.3* & 5KW 8000 ft. 10KW 8000 ft. 20KW 7000 ft.15KW 8000 ft.Ambient Temp. Limits Min. -45°C, (-49°F) Max. 40°C, (104°F)MTR/BLADE RPM 1725 1725 1725Propeller Fan 3 Wing, Alum. 12" Dia. 16" Dia. 20" Dia.MotorMotor Voltage/Phase same as element. PSC,Explosion-Proof, Permanently Lubricated, Ball Bearing1/4 HP 1/4 HP 1/2 HPHEAT Heat Exchanger Heavy wall, liquid filled with immersion elements.EXCHANGER Core Material Steel with aluminum fins.Heat Transfer FluidEthylene-glycol solution, protected to -45°C (-49°F)Heating ElementsThree, low watt density, immersion type copper sheathed.PROTECTION Thermal Cut-Out Snap action capillary type rated 100,000 cycles pilot duty.Relief ValveStainless steel and aluminum construction, opens @ 200 PSICABINET Cabinet 14 gauge cold rolled steel, epoxy coated, individually adjustable louvers.Fan GuardWire, less than 1/4" spacing, plated, split design for easy removalFastenersZinc plated.Conduit Material3/4 rigid metalControl BoxCast aluminum with over-sized opening. (2) 1" NPS with conduits stops for field wiring.Hanger Connections5/8" NC tap, 2 holes.CONTROLS Contactors Heavy duty, break all ungrounded conductors rated 100,000 cycles @ full load.Built-in and pre-wired.Control TransformerBuilt-in and pre-wired - 24 volt secondary (standard) 120 volt (optional)Control Circuits24 volt standard on all models120 volt optional on all models (not available on 600V models)Line voltage on 208 and 240 volt models onlyRemote wall mountedExplosion proof 40° - 90°F operating range 22AThermostat Model TW161 125-277VAC - 3/4HP @ 125VAC; 1 1/2 HP @ 250-277VACBuilt-in "T" Option125 VA pilot duty Sensing Bulb and Capillary made from 300 Series Stainless Steel ASW TubeHeater Net Weight 132 lbs. 3 & 5KW 158 lbs. 10KW 190 lbs. 15 & 20KWShipping Weight 167 lbs. 7.5KW 225 lbs. 25KWELECTRIC HEATING PRODUCTS 15


Mounting Bracket KitsColumn Stabilizing ComponentsMounting Arm Assy.Attachment Assy.1/2" Pipe(Not Supplied)Roof or OverheadStructure3 1/2" Schedule 40 (Pipe),(Not Supplied)BHHMHanging Mounting KitSimple and economical if adequateoverhead structure exists. Requires 1/2"pipe, cut and threaded (no supplied).PIPE KITSBHPM 75BHPM 10BHPM 25HANGING KITSBHHM3 to 7.5KW Models10KW Models15 to 25KW ModelsAll ModelsBase AssemblyAttachmentAssemblyWall BracketMounting ArmWALL MOUNTING KITSBHWM 75 3 to 7.5KW ModelsBHWM 10 10KW ModelsBHWM 25 15 to 25KW ModelsBHPMPipe Mounting KitParticularly useful in buildings withinsufficient strength to use other typeof mounts. Requires 3 1/2" pipe (4" O.D.- not supplied).Wall or StructureBHWMWall Mounting KitIdeal for use in buildings that havesubstantial walls. Arm only can also bebolted directly to structural steel.Sample SpecificationsContactors shall supply and install <strong>Brasch</strong> typeBHUH explosion-proof suspended fan-forced unitheaters of the capacity and voltage listed on theplans. Heaters shall be UL listed for Class I, Group D,Divisions 1 & 2 and Class II, Groups E, F and G,Divisions 1 & 2, UL temperature code shall be T3B(165°C) for Class 1, and T3B (165°C) for Class II,indicating maximum operating surfacetemperatures.Physical DimensionsInchesCModel A B 3Ø 1Ø D E F GBHUH-A 17 3/4 22 3/8 19 3/4 20 5/8 16 1/4 10 1/2 14 3BHUH-B 20 3/4 26 3/8 20 3/4 21 5/8 20 1/4 11 1/2 18 4BHUH-C 24 3/4 30 3/8 22 1/2 — 24 1/4 12 1/2 22 4 1/2Heat exchangers shall be heavy walled, liquid filled,with three, low watt density, immersion typecopper sheathed elements hermetically sealed intothe core along with the high limit thermal cut-out.Heat transfer fluid shall be ethylene-glycol solution,protected to -45°C (-49°F).Motors shall be PSC, explosion-proof, permanentlylubricated, ball bearing type, 1725 rpm.Contactors shall be built-in and pre-wired into anexplosion-proof enclosure. Contactors shall beheavy duty and break all ungrounded conductorsand be rated for 100,000 cycles at full load. Controltransformers shall be built-in and pre-wired.Control circuits shall be 24 volt.Cabinet shall be 14 gauge cold rolled steel, epoxycoated plated fan guard shall have less than 1/4inch spacing to conform with OSHA requirements.All fasteners shall be zinc plated. Heater conduitsshall be cadmium plated seamless steel oraluminum.Mounting Kits<strong>Brasch</strong> offers three mounting kits available for theSeries: the BHPM Pipe Mounting Kit; the BHHMHanging Mounting Kit; and the BHWM WallMounting Kit. Each of these is illustrated anddescribed in this brochure.To order, specify thetype of kit with the heater model desired. Consultour Sales Department for details.16 BRASCH MANUFACTURING COMPANY, INC.


Performance DataHeater Line Air Temp Min Cir Max Fuse Min. WireSize Model Volts Phase KW Amps Amps BTU/HR Rise Deg F Ampacity Amps AWG?*BHUH 7.5 BHUH 3-2081 208 1 3.0 14.4 16.3 10250 16.6 20.4 25 10BHUH 3-2083 208 3 3.0 8.3 9.8 10250 16.6 12.3 15 14BHUH 3-2401 240 1 3.0 12.5 14.8 10250 16.6 18.5 20 12BHUH 3-2403 240 3 3.0 7.2 8.6 10250 16.6 10.8 15 14BHUH 3-4803 480 3 3.0 3.6 4.3 10250 16.6 5.4 15 14BHUH 3-6003 600 3 3.0 2.9 3.5 10250 16.6 4.4 15 14BHUH 5-2081 208 1 5.0 24.0 26.0 17100 27.6 32.4 35 8BHUH 5-2083 208 3 5.0 13.9 15.4 17100 27.6 19.2 20 12BHUH 5-2401 240 1 5.0 20.8 23.1 17100 27.6 28.9 30 10BHUH 5-2403 240 3 5.0 12.0 13.4 17100 27.6 16.8 20 12BHUH 5-4803 480 3 5.0 6.0 6.7 17100 27.6 8.4 15 14BHUH 5-6003 600 3 5.0 4.8 5.4 17100 27.6 6.8 15 14BHUH 7.5-2081 208 1 7.5 36.1 38.0 25600 41.4 47.5 50 8BHUH 7.5-2083 208 3 7.5 20.8 22.3 25600 41.4 27.9 30 10BHUH 7.5-2401 240 1 7.5 31.3 33.6 25600 41.4 42.0 45 8BHUH 7.5-2403 240 3 7.5 18.0 19.4 25600 41.4 24.3 25 10BHUH 7.5-4803 480 3 7.5 9.0 9.7 25600 41.4 12.2 15 14BHUH 7.5-6003 600 3 7.5 7.2 7.8 25600 41.4 9.8 15 14BHUH 10 BHUH 10-2083 208 3 10.0 27.8 29.3 34150 21.7 36.6 40 8BHUH 10-2401 240 1 10.0 41.7 44.0 34150 21.7 55.0 60 6BHUH 10-2403 240 3 10.0 24.1 25.5 34150 21.7 31.8 35 8BHUH 10-4803 480 3 10.0 12.0 12.7 24150 21.7 15.9 20 12BHUH 10-6003 600 3 10.0 9.6 10.2 34150 21.7 12.8 15 14BHUH 25 BHUH 15-2083 208 3 15.0 41.6 43.5 51200 19.2 54.4 60 6BHUH 15-2403 240 3 15.0 36.1 38.1 51200 19.2 47.6 50 8BHUH 15-4803 480 3 15.0 18.0 19.0 51200 19.2 23.8 25 10BHUH 15-6003 300 3 15.0 14.4 15.2 51200 19.2 19.0 20 12BHUH 20-4803 480 3 20.0 24.1 25.1 68300 26.2 31.3 35 8BHUH 20-6003 600 3 20.0 19.2 20.0 68300 26.2 25.1 30 10BHUH 25-4803 480 3 25.0 30.1 31.1 85400 32.8 38.8 40 8BHUH 25-6003 600 3 25.0 24.1 24.9 85400 32.8 31.1 35 8*Supply conductors must be suitable for 90°CControls■ Standard unit includes 24 volttransformer and contactors■ 120 volt option — delete 24 suffixon model # — add 120 to model #Thermostats■ Add suffix "T" to model # for built-inthermostat■ Remote thermostat — see wallthermostat specifications on page 16■ 600 volt models available with 24volt controls onlyELECTRIC HEATING PRODUCTS 17


Shown:3 Phase Heater with 120 Volt ControlFusing Not Required on 24V Class IITransformer18 BRASCH MANUFACTURING COMPANY, INC.


BRASCH ARCHITECTURAL ELECTRIC CONVECTORSArchitectural Convectors are custombuilt with unsurpassed craftsmanship.Standard length and custom fitteddraft barrier, sill height and pedestalheaters meet the most demandingarchitectural specifications. Low initialcost and negligible maintenance makethem suitable for all projects stressingenergy and cost optimization.Application<strong>Brasch</strong> Architectural Convectors areideal for perimeter heating of schools,lobby areas, public buildings, nursinghomes and other commercialapplications providing individual roomcontrol and warm air draft protectionfor wall and window exposures.Heating capabilities to 750 watts perfoot in a wide variety of cabinet stylesprovide continuous clean horizontallines to complement any buildingproject. Enclosures are available instandard and special painted colors andin clear and color anodized finishes.Construction Features■ Snap-fit construction savesinstallation time, eliminatesunsightly screws.■ Pencil-proof louvers have 1/4 inchspacings.■ Heavy gauge extruded aluminumgrilles with 15 degree angledlouvers direct heated air away fromwall for cleaner operation.■ Enclosures are fabricated of heavygauge materials to assurecompliance with architecturalrequirements to withstand years ofrough usage. All enclosures can befinished to match window mullions,wall surfaces and interior decor.■ Multiple heaters factory wired onthe same backplate are available upto maximum front enclosure lengths(see Table 1).■ Front cover enclosures are availablein continuous lengths up tomaximums (see Table 1) to eliminateunnecessary splices (special order).Aluminum only.■ Full length thermal cutout withautomatic reset preventsoverheating when airflow is blocked.Heating elements mounted on freefloating nylon bushings for quietoperation.■ Aluminum sheath element hasmechanically bonded fins for cooleroperating temperatures.■ Built-in 1/2 inch EMT raceway allowsfield wiring from either end. (3/4inch EMT also available).■ Control section can accommodateoptional controls as required.■ Junction boxes in heaters (exceptDBTS) will accept most controls (seepage 23).■ Optional controls includethermostat, disconnect (with orwithout 20 amp fuse and fuseblock), power relay, transformer relayand PE switch.Snap-fit Construction1/4" Pencil-proof LouversAluminum Front Cover■ Accessories (see page 23) includeend caps, wall trim splice plates,inside and outside corners, mullionfronts, inside fillers, blank sections,control sections, 1/4 inch wire meshunder grille, pedestals and duplexreceptacles.■ Disconnect switch and relay,separately or in combination withthermostat, allow for right hand wireentry. Integral thermostat allowswire entry at either end.FinishesThe standard finish on all heaters is ASIBronze paint. Other standardized paintcolors which are available are EggshellWhite, Beige, Gray, and Black. Anodizedfinishes can be provided on aluminumenclosure heaters. Those available are204R1 Clear, 313R1 Bronze and Black.Actual samples of any of the foregoingfinishes can be provided upon request.Additionally, special painted colors canbe provided to match submitted colorsamples. Heater backs (except RDBT-PD) are not finished unless specified.Back CoverHigh EfficiencyBonded AluminumFins Assure CoolSurface TemperaturesJunction BoxFeatures Built-inThermostat AndDisconnect if RequiredFull LengthThermal OverloadProtectionELECTRIC HEATING PRODUCTS 19


Standard Profile Draft BarriersDBF & DBTThese heaters have a 6" x 3 1/2" profilewith a snap-fit extruded aluminumenclosure and a 12 ga. aluminumbackplate. The DBF is available with upto 250 watts per foot of heating and theDBT with up to 300 watts per foot ofheating. DBF is designed for floormounting with front inlet and topoutlet. DBT is designed for wallmounting with bottom inlet and topoutlet but pedestals can be supplied forfloor mounting.Low Profile Draft BarriersDBTS & CBThe DBTS heater has a 4" x 2 5/8" profileand the CB heater has a 4 1/2" x 2 5/8"profile. Both have a snap-fit extrudedaluminum enclosure and a 14 ga.aluminum backplate.The DBTS heater isavailable with up to 300 watts per foot ofheating.The CB heater is available with upto 250 watts per foot of heating. Both aredesigned for wall mounting with bottominlet and top outlet but pedestals can besupplied for floor mounting.Table 1: Model ComparisonsDual Element Draft BarriersDBCF & DBCTThese heaters have a 7" x 5" profile witha snap-fit extruded aluminumenclosure and a 10 ga. aluminumbackplate. The DBCF is available with upto 650 watts per foot of heating and theDBCT with up to 750 watts per foot ofheating. DBCF is designed for floormounting with front inlet and topoutlet. DBCT is designed for wallmounting with bottom inlet and topoutlet but pedestals can be supplied forfloor mounting.Sill Height Draft Barriers ASHDBThe ASHDB has a standard 5 1/2" depthand heights are available from 8" to 20"in 1/16" increments—specify heightrequired. The front cover is 16 ga. steeland the backplate is 18 ga. steel. Thegrille is extruded aluminum. TheASHDB is available with up to 500watts per foot of heating. The heater isdesigned for wall mounting withbottom inlet and top outlet. Pedestalscan be supplied for floor mounting of8" height only.Rounded Pedestal DraftBarriers RDBT-PDThe RDBT-PD heater has a rounded 6" x7" profile with a flat bottom and a flattop and has an extruded aluminumenclosure.The heater is supported on 13/4" - 2 1/4" adjustable pedestals.TheRDBT-PD is available with up to 300watts per foot of heating.The heater isdesigned for floor mounting withbottom inlet and top outlet.Standard ElementsThe following standard elements areavailable in even foot lengths at thewatts per foot heat outputs shown forsingle phase voltages:________________________________277 240 208 120125 94 93 125165 124 106 188188 141 113 250200 150 141250 188 188333 250 212375 282 250DBCF, DBCT and ASHDB can be furnishedwith any combination of two elements.Special elements at different heatoutputs and/or lengths are available.Enclosure Maximum Front FinishesDimension Heat Enclosure/Model Type (H x D) Airflow Watts/Ft Max Length Grilles Mounting Standard OptionalDBF Standard 6" x 3 1/2" Front Inlet 250 .100" Extruded Extruded Floor Painted Color or Clear AnodizedTop Outlet Aluminum/15 Ft. Aluminum Bronze Std. and Spcl. Painted ColorsDBT Standard 6" x 3 1/2" Bottom Inlet 300 .100" Extruded Extruded Wall Painted Color or Clear AnodizedTop Outlet Aluminum/15 Ft. Aluminum Bronze Std. and Spcl. Painted ColorsDBTS Low Profile 4" x 2 5/8" Bottom Inlet 300 .070" Extruded Extruded Wall Painted Color or Clear AnodizedTop Outlet Aluminum/15 Ft. Aluminum Bronze Std. and Spcl. Painted ColorsCB Low Profile 4 1/2" x 2 5/8" Bottom Inlet 250 .070" Extruded Extruded Wall Painted Color or Clear AnodizedTop Outlet Aluminum/15 Ft. Aluminum Bronze Std. and Spcl. Painted ColorsDBCF Dual Element 7" x 5" Front Outlet 650 .100" Extruded Extruded Floor Painted Color or Clear AnodizedTop Outlet Aluminum/12 Ft. Aluminum Bronze Std. and Spcl. Painted ColorsDBCT Dual Element 7" x 5" Bottom Outlet 750 .100" Extruded Extruded Wall Painted Color or Clear AnodizedTop Outlet Aluminum/12Ft. Aluminum Bronze Std. and Spcl. Painted ColorsASHDB Sill Height 8" - 20" Bottom Inlet 500 16 ga. Steel/ Extruded Wall Painted Std. and Spcl. Painted ColorsX 5 1/2" Top Outlet 10 Ft. Aluminum BronzeRDBT-PD Rounded 6" x 7" Bottom Inlet 300 .100" Extruded Extruded Floor Painted Color or Clear AnodizedTop Outlet Aluminum/12 Ft. Aluminum Bronze Std. and Spcl. Painted Colors20 BRASCH MANUFACTURING COMPANY, INC.


AccessoriesICInside CornerOC Outside CornerECEnd Cap—left or right(N/A RDBT-PD)IEC Inside Fitting End Cap—left or right (N/A DBTS, CB,DBCF, AHSDB)WT Wall TrimSP Splice Plate, 1 1/2" - 6"(N/A RDBT-PD)MF Mullion Front to 1 foot(DBF, DBT, CB only)IFInside Filler to 1 foot(DBF, DBT, DBCT only)BSBlank Section—specifylength (1'-0" to 10'-0")ASB Conduit 3/4" Raceway(1/2" Standard)ASB Mesh 1/4" wire mesh under grilleASB DR Duplex ConvenienceReceptaclesASB PD Pedestals—specify 2" or 3"(3" over 300W/Ft)ControlsCS Control Section—6" or 12"ITS Single Pole Thermostat—20 ampsITD Double Pole Thermostat—20 ampsIDS Double Pole Disconnect—20 ampsIDSF Double Pole Disconnectw/20 amp fuse and fuseblockPRPower Relay—18 ampsTRTransformer RelayPEPressure Electric SwitchDBTS requires a CS with any controls. Asix inch CS will accept 1 or 2 controls, atwelve inch CS will accept 3 controls. CBwill accept only a thermostat,disconnect or power relay in thejunction box. More or other controlsrequire a CS. All other heaters will acceptany two of the following controls to beinstalled in the junction box—disconnect and thermostat, disconnectand power relay or disconnect and PEswitch. Increase the length of the heaterenclosure by 6" or 12" when using acontrol section. Integral thermostats aremounted on the left side unlessotherwise specified; integral disconnectsare mounted on the right side unlessotherwise specified; integral relays aremounted on the left side unlessotherwise specified. Heaters are wiredfor either right or left hand entry wherethere are no controls. Otherwise, entry isin the junction box containing thecontrols.How to OrderExample: Model NumberDBF-2200-277-ASI Bronze-ITSModelLength (in feet)Watts per footVoltageFinish ColorBuilt-in ControlsWhen Ordering, specify:■ Model Number■ Length (in feet)■ Watts Per Foot■ Voltage■ Finish Color■ Built-in ControlsELECTRIC HEATING PRODUCTS 21


Sample SpecificationElectric convectors shall be architectural series by <strong>Brasch</strong> Manufacturing Co., Inc. as scheduled:Series DescriptionHeight By DepthDBF—Draft Barrier (front inlet) 6" x 3 1/2"DBT—Draft barrier (bottom inlet) 6" x 3 1/2"DBTS—Draft barrier (bottom inlet) 4" x 2 5/8"CB—Draft barrier (bottom inlet) 4 1/2" x 2 5/8"DBCF—Draft barrier (front inlet) 7" x 5"DBCT—Draft barrier (bottom inlet) 7" x 5"ASHDB—Sill Height (bottom inlet) 8" - 20" x 5 1/2"RDBT-PD Rounded Pedestal (bottom inlet) 6" x 7"Draft barrier shall be fabricated ofaluminum extrusions with 1/4" pencilprooflouvers at a 15" angle forimproved convection and cleaneroperation. Cabinets to have cleansquare corners, suitable for front orbottom intake and heating at watts perfoot as scheduled.Sill height convectors shall befabricated of 16 gauge furniture steelwith 14 gauge extruded aluminum,pencil-proof louvers installed at a 15°angle for improved convection andcleaner operation.Enclosure covers, louvers and end capswill snap-fit together without screws orfasteners for easy maintenance. Wallmountedunits shall have pre-punchedslots for quick installation. Pedestal andmullion-to-mullion units to have solidfinished backs without slots. Standardbacked acrylic bronze or optionalpainted or anodized finish will beprovided in architectural colors asscheduled.Provide full length linear thermalcutout with automatic reset on all unitsto prevent overheating from blockedairflow. Provide built-in EMT racewaywith factory wiring and 3/4" knockoutson side and rear of junction boxes ateach end. Heater to accept field wiringat either end when optional controlsare not included. Blank sections shallbe fully enclosed for branch circuitwiring. Heating elements shall bealuminum sheath with mechanicallybonded fins to maximize heat transferand limit fin temperatures to 330°F.Elements shall be centered in freefloatingnylon bushings for quietoperation. Per schedule, controlsinclude single or double polethermostats, disconnect switches, andrelays. Thermostats shall be adjustable(tamperproof ) through dischargelouver. Separate control sections shallinclude factory mounted PE switches,mercury contactors, circuit breakersand control transformers (asscheduled).Accessories shall include end caps, walltrim, splice plates, inside and outsidecorners, and blank sections ofmatching material for visual continuity.All heaters and controls shall be listed byUnderwriters Laboratories, Inc. andwarranted for one year from date of sale.22 BRASCH MANUFACTURING COMPANY, INC.


Limited WarrantyAll <strong>Brasch</strong> Manufacturing Company,Inc. products covered in this bulletinare warranted against defects inworkmanship and materials for oneyear from date of purchase. Thiswarranty does not apply to damagefrom accident, misuse or alteration; norwhere the connected voltage is morethan 5% above product nameplatevoltage; nor to equipment improperlyinstalled or wired or maintained inviolation of installation instructions.This warranty is valid only in the fiftystates of the United States. No otherwritten or oral warranty applies. Noemployee, agent, dealer or otherperson is authorized to extendwarranty on behalf of <strong>Brasch</strong>Manufacturing Company.The customer shall be responsible forall costs incurred in the removal orreinstallation and shipping of theproduct for repairs. Inoperative unitsshould be returned to <strong>Brasch</strong>, attentionof Service Manager for repair orreplacement at our option. Product willbe returned freight prepaid. Repair orreplacement is the exclusive remedyavailable from <strong>Brasch</strong> who is not liablefor damages of any kind, includingincidental and consequential damage.


2310 Millpark DriveM a r y l a n d H e i g h t s , MO 63043314.291.0440 - Fax 314.291.0646e-mail: sales@braschmfg.comwww.braschmfg.com©<strong>Brasch</strong> Manufacturing Company, Inc.