12.07.2015 Views

NEW 2010 Circular Interconnects Catalog - All sections - 12-C3

NEW 2010 Circular Interconnects Catalog - All sections - 12-C3

NEW 2010 Circular Interconnects Catalog - All sections - 12-C3

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Effect of Temperature on EMI FilterAttenuationAmphenolAerospaceNote: Below are typical capacitance values. Other capacitance values are available from 5pf to 400 NF in onecapacitor element. Please consult factory for part numbers.ATTENUATION (db)10080604020MF-1HF-1TYPICAL INSERTION LOSSVHF-1VHF-20.15 .5 1 3 10 30 100 300 1000FREQUENCY MHzUHF-2UHF-1<strong>All</strong> performance between1000 and 10,000 isgreater than 60 dB.Measurements weregreater than equipmentsensitivity (60 dB).38999III II I SJT26482 83723 III 5015Matrix 2Matrix PyleCrimp RearRelease MatrixTYPICAL INSERTION LOSS (dB)PER MIL-STD-220, 5 ADC, 25°CCapacitance 1MHz 3MHz 10MHz 30MHz 100MHz 300MHz 1000MHz375 pf UHF 10 0 1 8 16 – –750 pf UHF 20 0 3 10 19 – –2500 pf VHF 20 2 8 20 28 – –7000 pf VHF 15 9 17 23 40 – –16000 pf HF 16 14 20 24 80 – –MF-1*Typical Capacitance = 1,000,000 pf Min. 800,000 pf Max. 1,600,000 pfType PiTemp. FCO 1MHz 3MHz 10MHz 30MHz 100MHz 300MHz 1000MHz–55°C – 18 – 64 80 80 80 80Room 7.94K 55 – 80 80 80 80 80+<strong>12</strong>5°C – 22 – 70 80 80 80 80HF-1*Typical Capacitance = 16,000 pf Min. 9,800 pf Max. 24,000 pfType Cascaded PiTemp. FCO 1MHz 3MHz 15MHz 50MHz 100MHz 300MHz 1000MHz–55°C – 2 6 24 62 80 80 80Room 648K 3 9 50 80 80 80 80+<strong>12</strong>5°C – 0 6 30 62 80 80 80VHF-1Typical Capacitance = 7,000 pf Min. 4,900 pf Max. <strong>12</strong>,000 pfBand G, Type PiTemp. FCO 1MHz 3MHz 10MHz 30MHz 100MHz 300MHz 1000MHz–55°C – 1 2 8 21 44 61 65Room 1.27M 1 6 18 42 62 72 75+<strong>12</strong>5°C – 0 2 9 24 45 62 64Most filter attenuation curves and capacitance values areexpressed at 25°C. However, temperature can affect thecapaci tance of a titanate filter element, affecting the insertionloss that the element will cause.In order to assist the user in anticipating the effect of varioustem peratures, the following charts applicable to Amphenol ®filter con nectors utilizing MF-1, HF-1, VHF-1, VHF-2, UHF-1and UHF-2 filters are provided. Please note that all insertionloss (attenuation) values given were measured with no loadapplied. The band designations refer to MIL-STD-2<strong>12</strong>0.VHF-2Typical Capacitance = 2,500 pf Min. 1,900 pf Max. 4,000 pfBand E, Type PiTemp. FCO 1MHz 3MHz 10MHz 30MHz 100MHz 300MHz 1000MHz–55°C – 0 2 7 17 40 58 71Room 3.3M 0 2 8 24 46 61 71+<strong>12</strong>5°C – 0 3 10 26 46 63 69UHF-2Typical Capacitance = 750 pf Min. 500 pf Max. 1,100 pfBand C, Type PiTemp. FCO 1MHz 3MHz 10MHz 30MHz 100MHz 300MHz 1000MHz–55°C – 0 0 3 9 25 46 61Room <strong>12</strong>.7M 0 0 3 10 28 46 61+<strong>12</strong>5°C – 0 0 3 10 24 42 60UHF-1Typical Capacitance = 375 pf Min. 290 pf Max. 450 pfBand B, Type PiTemp. FCO 1MHz 3MHz 10MHz 30MHz 100MHz 300MHz 1000MHz–55°C – 0 0 1 6 21 43 58Room 21.9M 0 0 1 8 18 42 56+<strong>12</strong>5°C – 0 0 1 8 17 38 5026500 PylePrintedCircuit BoardEMI FilterTransientFiber OpticsHigh SpeedContactsOptionsOthersNote: F CO= Cut-off Frequency* Consult Amphenol, Sidney, NY for availability.Contact Amphenol Aerospace for more information at 800-678-0141 • www.amphenol-aerospace.com283

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!