12.07.2015 Views

Rivets on aluminium - Sisteme-fatade.ro

Rivets on aluminium - Sisteme-fatade.ro

Rivets on aluminium - Sisteme-fatade.ro

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>g>Rivets</str<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>g> <st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>aluminium</st<strong>ro</strong>ng>Fr<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>t viewFix PointSliding pointIn order to achieve a correct and safe <st<strong>ro</strong>ng>aluminium</st<strong>ro</strong>ng> sub-c<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>structi<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> the supplier of the system should be c<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>sulted.However there are a few rules to c<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>sider when it comes to the functi<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>ality of the facade boards.• Length of the <st<strong>ro</strong>ng>aluminium</st<strong>ro</strong>ng> p<strong>ro</strong>fi les is minimized to 3000 mm (<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>e storey).• The <st<strong>ro</strong>ng>aluminium</st<strong>ro</strong>ng> p<strong>ro</strong>fi les must be fi xed with <st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>e fi x-point at the middle or the upper end and all other fi xati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>s as sliding points.• All joints of the <st<strong>ro</strong>ng>aluminium</st<strong>ro</strong>ng> p<strong>ro</strong>fi les must be aligned so they can be followed by joints of the facade boards.A board must never c<strong>ro</strong>ss a joint in the p<strong>ro</strong>fi les.• The facade boards must be fi xed with a fi x-point in the middle of the board. All other fi xati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>s are sliding points.In case of two intermediate supporting p<strong>ro</strong>fi les two fi x-points at the same horiz<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>tal level are allowed.• Important! Setting of the rivets takes place starting with the fix-points, thereafter the sliding points above andfinally the sliding points below.Horiz<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>tal orientati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>Façade boards may be installed in a horiz<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>tal positi<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> a vertical sub-structure. On metal framing the edge distance a ≥ 40 mm andcorner distance c ≥ 100 mm. Every 12 m of the facade a double framing must be installed in order to create a dilatati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> joint.Fix PointSliding point17


<str<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>g>Rivets</str<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>g> <st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>aluminium</st<strong>ro</strong>ng>Horiz<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>tal c<strong>ro</strong>ss secti<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> vertical joint1 Load bearing wall3 Insulati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>5 Air gap min 25 mm8 EPDM underlay 90 mm11 Rivet SS 4.0 x 19/1416 Aluminium frame system21 Facade boarda Edge distance min 40 mmb Joint width 8 mmHoriz<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>tal c<strong>ro</strong>ss secti<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> intermediate support1 Load bearing wall3 Insulati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>5 Air gap min 25 mm7 EPDM underlay 30 mm11 Rivet SS 4.0 x 19/1416 Aluminium frame system21 Facade board18


<str<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>g>Rivets</str<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>g> <st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>aluminium</st<strong>ro</strong>ng>Horiz<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>tal c<strong>ro</strong>ss secti<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> external corner1 Load bearing wall3 Insulati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>5 Air gap min 25 mm7 EPDM underlay 30 mm8 EPDM underlay 90 mm11 Rivet SS 4.0 x 19/1416 Aluminium frame system17 Aluminium angle 40 x 40 x 2 mm21 Facade boarda Edge distance min 40 mmb Joint width 8 mme Dist. to wall fi xing max 200 mmHoriz<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>tal c<strong>ro</strong>ss secti<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> internal corner1 Load bearing wall3 Insulati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>5 Air gap min 25 mm7 EPDM underlay 30 mm8 EPDM underlay 90 mm11 Rivet SS 4.0 x 19/1416 Aluminium frame system17 Aluminium angle 40 x 40 x 2 mm21 Facade boarda Edge distance min 40 mmb Joint width 8 mm19


<str<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>g>Rivets</str<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>g> <st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>aluminium</st<strong>ro</strong>ng>Horiz<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>tal c<strong>ro</strong>ss secti<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> window(Window recess max 200 mm without ventilati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>)1 Load bearing wall3 Insulati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>5 Air gap min 25 mm7 EPDM underlay 30 mm8 EPDM underlay 90 mm11 Rivet SS 4.0 x 19/1416 Aluminium frame system17 Aluminium angle 40 x 40 x 2 mm21 Facade board22 Windowa Edge distance min 40 mmb Joint width 8 mmVertical c<strong>ro</strong>ss secti<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> horiz<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>tal joint1 Load bearing wall3 Insulati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>5 Air gap min 25 mm8 EPDM underlay 90 mm10 Fixing point p<strong>ro</strong>fi le/bracket11 Rivet SS 4.0 x 19/1415 Aluminium p<strong>ro</strong>fi le16 Aluminium frame system21 Facade boardb Joint width 8 mmc Corner distance min 100 mmNote! Boards must never be fi xed totwo separate p<strong>ro</strong>fi les!20


<str<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>g>Rivets</str<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>g> <st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>aluminium</st<strong>ro</strong>ng>Vertical c<strong>ro</strong>ss secti<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> foundati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>1 Load bearing wall3 Insulati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>5 Air gap min 25 mm8 EPDM underlay 90 mm10 Fixing point p<strong>ro</strong>fi le/bracket11 Rivet SS 4.0 x 19/1415 Aluminium p<strong>ro</strong>fi le16 Aluminium frame system18 Foundati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>21 Facade board23 Insect gratingc Corner distance min 100 mmd Ventilati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> inlet min 200 cm 2 /mf Overhang ca 30 mmVertical c<strong>ro</strong>ss secti<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> <strong>ro</strong>of edge1 Load bearing wall3 Insulati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>5 Air gap min 25 mm8 EPDM underlay 90 mm10 Fixing point p<strong>ro</strong>fi le/bracket11 Rivet SS 4.0 x 19/1415 Aluminium p<strong>ro</strong>fi le16 Aluminium frame system19 Eave21 Facade boardc Corner distance min 100 mmd Ventilati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> outlet min 200 cm 2 /mf Overhang ca 30 mm21 GEVELBEKLEDING VOOR CREATIEVE ARCHITECTUUR21


<str<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>g>Rivets</str<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>g> <st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>aluminium</st<strong>ro</strong>ng>Vertical c<strong>ro</strong>ss secti<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> window sill1 Load bearing wall3 Insulati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>5 Air gap min 25 mm8 EPDM underlay 90 mm10 Fixing point p<strong>ro</strong>fi le/bracket11 Rivet SS 4.0 x 19/1415 Aluminium p<strong>ro</strong>fi le16 Aluminium frame system20 Window sill21 Facade board22 Windowc Corner distance min 100 mmd Ventilati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> outlet min 200 cm 2 /mf Overhang ca 30 mmVertical c<strong>ro</strong>ss secti<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> window upper edge(Window recess max 200 mm without ventilati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>)1 Load bearing wall3 Insulati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng>5 Air gap min 25 mm8 EPDM underlay 90 mm10 Fixing point p<strong>ro</strong>fi le/bracket11 Rivet SS 4.0 x 19/1415 Aluminium p<strong>ro</strong>fi le16 Aluminium frame system21 Facade board22 Window23 Insect gratingc Corner distance min 100 mmd Ventilati<st<strong>ro</strong>ng>on</st<strong>ro</strong>ng> inlet min 200 cm 2 /mf Overhang ca 30 mm22

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!