12.07.2015 Views

Compact cylinders ADN/AEN, to ISO 21287 - Allied Automation, Inc.

Compact cylinders ADN/AEN, to ISO 21287 - Allied Automation, Inc.

Compact cylinders ADN/AEN, to ISO 21287 - Allied Automation, Inc.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Compact</strong> <strong>cylinders</strong> <strong>ADN</strong>-EL, standard port pattern, with end position lockTechnical dataFunctionVariantsK2-N- Diameter20 … 100 mm-T- Stroke length10 … 500 mmK5K8-H- NoteAdditional measures are required foruse in safety-related control systems;in Europe, for example, the standardslisted under the EC MachineryDirectivemustbeobserved.Withoutadditional measures in accordancewith statu<strong>to</strong>ry minimum requirements,the product is not suitable foruse in safety-related sections ofcontrol systems.General technical dataPis<strong>to</strong>n ∅ 20 25 32 40 50 63 80 100Pneumatic connection M5 M5 Gx Gx Gx Gx Gx GxFemale pis<strong>to</strong>n rod M6 M8 M10 M12thread K5 M5 M6 M8 M10Male pis<strong>to</strong>n rod thread M8 M10x1.25 M12x1.25 M16x1.5K5 M10 M10 M12 M16Max. axial backlash with end [mm] 1.3 2.1position lockedConstructional designPis<strong>to</strong>nPis<strong>to</strong>n rodCylinder barrelEnd position lock ELB At both endsELV At frontELH At rearCushioningFlexible cushioning rings/pads at both endsPosition sensingVia proximity sensorType of mountingVia female threadsVia accessoriesMounting positionAny-H- Note• No screws with a head or similarmaybeusedinplaceoftheendposition lock, as there is a risk thatthe function will be impaired if theyare screwed in <strong>to</strong>o deeply.• The exhaust hole must not beclosed.• Locking can be performed from anystroke position, once the drive isbrought mechanically in<strong>to</strong> its endposition.• The end position lock has beendesigned <strong>to</strong> guard against the loaddropping in case of pressurefailure.• Operation of the cylinder inconjunction with a 3-way valve(especially with the function “midpositionclosed” and those with“metallic sealing”) should beavoided. The residual pressure thatis enclosed on the locking side ofthe cylinder can release the lockingfunction.• The cylinder must not be operatedwith external s<strong>to</strong>ps (e.g. shockabsorber, buffer, oil brake, etc.):– Itmaynotbepossible<strong>to</strong>reliablyreach the internal end position.– The locking mechanism can wearout prematurely. (In the event ofpressure drop in the oppositechamber <strong>to</strong> less than the lockingpressure, the locking pis<strong>to</strong>n willprematurely fall <strong>to</strong> its endposition.)2010/02 – Subject <strong>to</strong> change Internet: www.fes<strong>to</strong>.com/catalogue/...47

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!