12.07.2015 Views

Model: HFW-135 T5 HFW-135 T5 - Clickbox.ro

Model: HFW-135 T5 HFW-135 T5 - Clickbox.ro

Model: HFW-135 T5 HFW-135 T5 - Clickbox.ro

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECOE10WATER-COOLEDTHREE PHASE50 HZSTG.2 (FLEXIBLE SCHEME)DIESELGenerating RatesSERVICE PRP STANDBYPower kVA 131 143Power kW 105 114Rated Speed r.p.m. 1.500Standard Voltage V 400Available Voltages V 230 - 230/132 - 400/230 VRated at power factor Cos Phi 0,8HIMOINSA Company with quality certification ISO 9001HIMOINSA gensets are compliant with EC mark which includes the following directives:• 2006/42/CE Machinery safety.• 2006/95/EC Low voltage.• 2004/108/CE Elect<strong>ro</strong>magnetic compatibility.• 2000/14/EC Sound Power level. Noise emissions outdoor equipment. (amended by 2005/88/EC)• 97/68/EC Emissions of gaseous and particulate pollutants. (amended by 2002/88/EC & 2004/26/EC)• EN 12100, EN 13857, EN 60204QR CodeAmbient conditions of reference: 1000 mbar, 25ºC, 30% relative humidity. Power according to ISO 3046 normative.P.R.P. Prime Power - ISO 8528:Prime power is the maximum power available during a variable power sequence, which may be run for an unlimitednumber of hours per year, between stated maintenance intervals. The permissible average power output during a24 hours period shall not exceed 80% of the prime power. 10% overload available for governing purposes only.Standby Power (ISO 3046 Fuel Stop power):Power available for use at variable loads for limited annual time (500h), within the following limits ofmaximum operating time: 100% load 25h per year – 90% load 200h per year. No overload available.Applicable in case of failure of the main in areas of reliable electrical network.HIMOINSA HEADQUARTERS:Fábrica: Ctra. Murcia - San Javier, Km. 23,6 | 30730 SAN JAVIER (Murcia) SpainTel.+34 968 19 11 28 Fax +34 968 19 12 17 Fax +34 968 19 04 20 info@himoinsa.com www.himoinsa.comManufacture facilities:SPAIN • FRANCE • INDIA • CHINA • USASubsidiaries:ITALY | PORTUGAL | POLAND | GERMANY I SINGAPORE | UAE | MEXICO | PANAMÁ | ARGENTINACtra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com


<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECOEngine Specifications 1.500 r.p.m.ENGINE PRP STANDBYRated Output Kw 114,2 126Manufacturer<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>Engine TypeInjection TypeAspiration TypeCiylinders ArrangementFPT_IVECONEF67 TM 2ADiesel 4 st<strong>ro</strong>kes-cycleDirectTurbocharged and aftercooled6 - LBore and St<strong>ro</strong>ke mm 104 x 132Displacement L 6,7Cooling SystemLube Oil SpecificationsLiquid (water + 50% glycol)ACEA E3 - E5Compression Ratio 17,5 : 1Fuel Consumption StandBy l/h 32Fuel Consumption 100% PRP l/h 29,3Fuel Consumption 80 % PRP l/h 24,1Fuel Consumption 50 % PRP l/h 15,8Lube Oil Consumption Full Load0,5 % of fuel consumptionTotal oil capacity including tubes, filters L 17,2Total Coolant Capacity L 25,5Governor Type MechanicalAir Filter Type DryInner diameter exhaust pipe mm 70Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com


Generator<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECOGeneratorPoles Num 4Winding Conections (standard)Star-serieFrame Mounting S-3 11"1/2Insulation Class H classEnclosure (according IEC-34-5)Exciter SystemVoltage RegulatorBearingCouplingCoating typeIP23self-excited, brushlessA.V.R. (Elect<strong>ro</strong>nic)Single bearingFlexible discStandar (Vacuum impregnation)Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com


Cont<strong>ro</strong>l Panel <st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>s<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECOCE M 7CE C7CE A 7Auto-startF UNC IONAL IT YAutomatic Cont<strong>ro</strong>l Panel W ithout M ainsCont<strong>ro</strong>lAutomatic Cont<strong>ro</strong>l Panel With Mains Cont<strong>ro</strong>l(customer change over contactors)Automatic Cont<strong>ro</strong>l Panel With Mains Cont<strong>ro</strong>l(Himoinsa change over contactor with display)Automatic M ains Failure (wall mounted panel)(**) Pre-heating resistance in the Genset andBattery charger in the cont<strong>ro</strong>l panel included.Option available: Auto-start cont<strong>ro</strong>l panelwithout circuit breakerGeneral DescriptionP ANE L MODE LM 5AS 5AS 5AS5XCC2AC5C ONT R OL L E R MODECE M 7CE M 7* *CE A7CEM7+CEC7CE A7CEM 7The CEM7 cont<strong>ro</strong>ller unit isa device able to cont<strong>ro</strong>l deoperation, monitoring andp<strong>ro</strong>tection of a generating set.The cont<strong>ro</strong>ller unit consists of 2different modules:1. The VISUALIZATION module2. The MEASUREMENTS moduleVISUALIZATION MODULEP<strong>ro</strong>vides information about thestatus of the device and, at thesame time, allows the user tointeract with it. It consists on abacklit display and various LEDsfor monitoring the status of thecont<strong>ro</strong>ller and buttons that allowthe user to cont<strong>ro</strong>l, p<strong>ro</strong>gram andconfigure the functions of the unit.MEASUREMENTS MODULECont<strong>ro</strong>ls and monitors the cont<strong>ro</strong>lboard. It is located in the rear partof the panel, in order to reduce thewiring and to avoid elect<strong>ro</strong>magneticdisturbances. Every signal, sensorand actuator is connected to thismodule.The connexion between thevisualization module and themeasurements module is madewith a CAN communication bus. Thisfeature allows the intercommunionof other modules to the maincont<strong>ro</strong>ller with a scalability warranty.CEC 7The CEC7 cont<strong>ro</strong>ller unit is a net singssupervision equipment, and cont<strong>ro</strong>l and supplysupplier th<strong>ro</strong>ugh generating set. The cont<strong>ro</strong>llerunit consists of 2different modules:1. The VISUALIZATION module2. The MEASUREMENTS moduleVISUALIZATION MODULEThe visualization module p<strong>ro</strong>vides informationabout the status of the device and, at the sametime, allows the user to interact with it. Withthis visualization module the user is able tocont<strong>ro</strong>l, p<strong>ro</strong>gram and configure the functions ofthe unit. It consists on a backlight display andvarious LEDs for monitoring the status of thecont<strong>ro</strong>ller and buttons that allow the user tocont<strong>ro</strong>l, p<strong>ro</strong>gram and configure the functions ofthe unit.MEASUREMENTS MODULEThe measurements module cont<strong>ro</strong>ls andmonitors the cont<strong>ro</strong>l board. It is located in therear part of the panel, in order to reduce thewiring and to avoid elect<strong>ro</strong>magneticdisturbances.Every signal, sensor and actuator is connectedto this moduleThe connection between the measure moduleand visualization mode is made by means of aCAN BUS (Communication Bus). This p<strong>ro</strong>ducesan interconnectionbetween additional modules whichguarantees the p<strong>ro</strong>per working ofthe cont<strong>ro</strong>ller.CEA 7CEA7 cont<strong>ro</strong>ller is a supervisionequipment for mains signal and alsoa supervision and electrical supplyth<strong>ro</strong>ugh the genset. This cont<strong>ro</strong>ller iscomposed by 2 different modules:1. VISUALIZATION module2.MEASUREMENTS moduleVISUALIZATION MODULEThe visualization module p<strong>ro</strong>videsinformation about the status of thedeviceand, at the same time, allows the userto interact with it. With this visualizationmodule the user is able to cont<strong>ro</strong>l,p<strong>ro</strong>gramand configure the functions of the unit.MEASUREMENTS MODULEThe measurements module cont<strong>ro</strong>ls andmonitors the cont<strong>ro</strong>l board. It is locatedinthe rear part of the panel, in order toreducethe wiring and to avoid elect<strong>ro</strong>magneticdisturbances. Every signal, sensor andactuator is connected to this module.Connection between the measuremoduleand visualization mode is made bymeansof a CAN BUS (Communication Bus). Thisp<strong>ro</strong>duces an interconnection betweenadditionalmodules which guarantees the p<strong>ro</strong>perworking of the cont<strong>ro</strong>ller.Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com


<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECOCont<strong>ro</strong>l & Power Panel1. CM Cont<strong>ro</strong>l Panel.2. CP Power Panel.3. On/Off Switch..4. Emergency Stop.5. Main Line Circuit Breaker for overload p<strong>ro</strong>tection.6. Main bus /hardwire connection panel with safetyp<strong>ro</strong>tection.CE-7 Auto-start multilingual cont<strong>ro</strong>l panel1. Voltage between each Phase & Neutral2. Voltage between Phases3. Current (amps) on each Phase4. Frequency5. Active, Aparent & Reactive Power6. Power Factor7. Instant Power (KwH) and Accumulative power)8. Fuel level9. Oil pressure, coolant temperature, oil temperature10. Battery voltage, battery charging alternator voltage11. Engine Speed12. Hours running13. Multilingual (Spanish, English, French, Italian, Portuguese,Polish, German, Chinesse, Russian, Swedish, Norwegian)Engine AlarmsGenset AlarmsMains Alarms1. High coolant temperature.2. Low oil pressure.3. Battery charge alternator4. Start failure.5. Low water level.6. Fuel storage.7. Overspeed.8. Underspeed.9. Low battery voltage.10. High coolant temperature by sensor.11. Low oil pressure by sensor.12. Low fuel level by sensor.13. Unexpected shutdown.14. Stop failure.15. Low engine temperature.16. Genset voltage d<strong>ro</strong>ps.17. Emergency stop.1. Over-load2. Unbalanced voltage3. Over voltage4. Under voltage5. Over frequency6. Under frequency7. Over load8. Short-circuit9. Inverse Power10. Asymmetry among phases11. Genset contactor Failure1. Maximum Mains Voltage.2. Minimum Mains Voltage.3. Maximum Mains Frequency.4. Minimum Mains Frequency.5. Mains phase sequence failure.6. Mains power failure.7. Mains contactor switching failure.P<strong>ro</strong>grammable Alarms:There are 5 p<strong>ro</strong>grammable alarms ontext and action that could beassociated to any engine alarms andshowed on the auxiliary led 1 and 2of the displayCtra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com


Cont<strong>ro</strong>llers Features<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECOCEM 7 CEC 7 CEA 7 CEM7 + CEC7GENERATOR READINGSVoltage among phases • • • •Voltage among phases and neutral • • • •Amperage • • • •Frequency • • • •Apparent power (kVA) • • • •Active power (kW) • • • •Reactive power (kVAr) • • • •Power factor • • • •MAINS READINGSVoltage among phases x • • •Voltage among phase and neutral x • • •Amperage x • • •Frequency x • • •Aparent power x x • •Active power x x • •Reactive power x x • •Power factor x x • •ENGINE READINGSCoolant temperature • x • •Oil pressure • x • •Fuel level (%) • x • •Battery voltage • x • •R.P.M. • x • •Battery charge alternator voltage • x • •ENGINE PROTECTIONSHigh water temperature • x • •High coolant temperature by sensor • x • •Low engine temperature by sensor • x • •Low oil pressure • x • •Low oil pressure by sensor • x • •Low coolent level • x • •Unexpected shutdown • x • •Fuel storage • x • •Fuel storage by sensor • x • •Stop failure • x • •Battery voltage failure • x • •Battery charge alternator failure • x • •Overspeed • x • •Underspeed • x • •Start failure • x • •Emergency Stop • • • •ALTERNATOR PROTECTIONSHigh frequency • • • •Low frequency • • • •High voltage • • • •Low voltage • • • •Short-circuit • x • •Asymmetry among phases • • • •Incorrect phase sequence • • • •Inverse power • x • •Overload • x • •Genset signal d<strong>ro</strong>op • • • •• Standardx Not included• OptionalNOTE: All p<strong>ro</strong>tections are p<strong>ro</strong>grammable to make “warning” or “stop withcooling time” or “without”Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com


Cont<strong>ro</strong>llers Features<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECOCEM 7 CEC 7 CEA 7 CEM7 + CEC7COUNTERSTotal hour counter • • • •Partial hour counter • • • •Kilowatimeter • • • •Starts valid counters • • • •Starts failure counters • • • •Maintenance • • • •COMUNICATIONSRS232 • • • •RS485 • • • •Modbus IP • • • •Modbus • • • •CCLAN • x • •Software for PC • • • •Analogic modem • • • •GSM/GPRS modem • • • •Remote screen • x • •Telesignal •(8+4)•(8+4)•(8+4)J1939 • x • •FEATURESAlarms history (10) / (•+100) -10 (10) / (•+100) (10) / (•+100)External start • • • •Start inhibition • • • •Mains failure start •(CEC7) • • •Start under normative EJP • x • •Genset contactor activation • x x •Main & Genset contactor activation x • • •Fuel transfer cont<strong>ro</strong>l • x • •Engine temperature cont<strong>ro</strong>l • x • •Manual override • x • •P<strong>ro</strong>grammable alarms • x • •Genset start function in test mode • x • •P<strong>ro</strong>grammable outputs • x • •Multilingual • • • •SPECIAL FUNCTIONSPositioning GPSSynch<strong>ro</strong>nization with mainsMains Synch<strong>ro</strong>nismSecond Ce<strong>ro</strong> suppressionRAM 7Remote screenTimer•••••••••••••••••••••• Standardx Not included• OptionalCEC7: available when the cont<strong>ro</strong>ller CEC7 is incorparted to the installationMPS 5.0: available application when the module MPS 5. has been incorporated to the panel.Note: AS5 + CC2 configuration, will have all CEM7 funcionality plus CEC7 mains readings.Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com


<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECOGenerating Sets Standard and Optional FeaturesEngine· Diesel engine· 4 st<strong>ro</strong>kes-cycle· Water-cooled· 12V Electrical system· Radiator with blowing fan· water separator decanting filter (no visible level)· Mechanical governor· Dry air cleaner· Hot components and radiator guards· Mobile components guardsOptional :· Sender WT· Senders OP· Low water level sensorAlternator· Self-excited and Self-regulated· 4 poles· AVR governor· IP23 p<strong>ro</strong>tection degree· Insulation H class· Single drive-shaft· Flexible disc couplingElectrical system· Cont<strong>ro</strong>l and power electric panel, with measurements devices and cont<strong>ro</strong>ller (according to necessity and configuration)· 4 poles circuit breaker· Earth leakage p<strong>ro</strong>tection adjustable (time & sensibility) standard in M5 and AS5 configuration with MCCB· Battery charger (standard on automatic cont<strong>ro</strong>l panels)· Pre-heating resistance (standard on automatic cont<strong>ro</strong>l panels) / water jacket heater· Battery charge alternator with g<strong>ro</strong>und connection· Starting battery/ies installed and connected to the engine (supports included)· G<strong>ro</strong>und connection electrical installation with connection ready for g<strong>ro</strong>und pike (not supplied)Optional :· Battery disconnectorCtra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com


<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECOGenerating Sets Standard and Optional FeaturesSoundp<strong>ro</strong>ofed version· Oil sump extraction kit· Versatility to assemble high capacity metallic fuel tank chassis· Steel made chassis· Antivibration shock absorber· Fuel tank· Fuel level sensor· Emergency stop button· Sound attenuated canopy made of high quality steel metal.· High mechanical strenght· Low noise level· Attenuation th<strong>ro</strong>ugh high density <strong>ro</strong>ock wool material· Powder coating· Easy acces for service mainteance· Reinforced lifting eye to lift by crane· Bunded chassis (works as liquids retention tray)· Drain fuel tank cap· Drain chassis cap· Chasis ready for future mobile kit installation· Steel made residential silencer -35db(A) attenuation.Optional :· 3 way valve fuel filling (available in 1/2" and 3/8" fittings)· Fuel transfer pumpCtra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com


<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECOApplication DataExhaust SystemMaximum exhaust temperature ºC 467,8Exhaust Gas Flow Kg/s 0,194Maximum allowed back pressure kPa 5Exhaust Flange Size (external diameter) mm 120Heat evacuated th<strong>ro</strong>ugh exhaut pipe KCal/Kwh 628,8Air Inlet SystemIntake Air Flow m3/h 559Cooling Air Flow m3/s 3,2Alternator fan air flow m3/s 0,514Starting SystemStarting Motor Kw 3Starting Motor CV 4,08Recommended Battery Capacity Ah 100Auxiliary Voltage Vcc 12Fuel SystemFuel SystemFuel Oil SpecificationsDieselFuel Tank L 450Other Fuel tank capacity L 600, 1.100Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com


Dimensions<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECO(L)(H)(W)Weight and DimensionsLength mm 3.300Height mm 1.958Width mm 1.200Shipping Volume seaworthy (standard suplier) m3 7,75(*)Wet weight Kg 2.362Fuel tank capacity L. 450Autonomy Hours 19Sound Level db(A)@7m 70(*) (with standard accesories)STANDARD VERSION (Plastic tank)Himoinsa reserves the right to modify any characteristic without prior notice.Weights and dimensions based on p<strong>ro</strong>ducts standar. Illustrations may include optional equipment.Technical data described here correspond with the available information at the moment of printing.Industrial design under patent.Local DistributorCtra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com


<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECOAnother measures/dimensions of available versions(L)(H)(W)Weight and DimensionsLength mm 3.300Height mm 1.958Width mm 1.200Shipping Volume seaworthy (standard suplier) m3 7,75(*)Wet weight Kg 2.479Fuel tank capacity L. 600Autonomy Hours 25Sound Level db(A)@7m 70(*) (with standard accesories)HIGH CAPACITY VERSION (Steel tank)(L)(H)(W)Weight and DimensionsLength mm 3.300Height mm 2.171Width mm 1.200Shipping Volume seaworthy (standard suplier) m3 8,6(*)Wet weight Kg 2.582Fuel tank capacity L. 1.100Autonomy Hours 46Sound Level db(A)@7m 70(*) (with standard accesories)HIGH CAPACITY VERSION (Steel tank)Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com


CONTROL PANEL MODELM5Digital manual auto-start cont<strong>ro</strong>l panel and thermal magnetic p<strong>ro</strong>tection (according to voltage andphase) and differential relay. CEM7<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECOAS5Automatic cont<strong>ro</strong>l panel WITHOUT ATS (Automatic Transfer Switch) and WITHOUT mains cont<strong>ro</strong>l with CEM7.(*) As optional AS5 with CEA7. Automatic cont<strong>ro</strong>l panel without ATS (automatic transfer switch) andwith mains cont<strong>ro</strong>l.CC2Himoinsa External ATS WITH visualization display. CEC7Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com


CONTROL PANEL MODELAS5 + CC2Automatic with mains cont<strong>ro</strong>l and ATS with visualization. The visualization will be in the genset andin the ATS box. CEM7+CEC7<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECOAC5Automatic Mains Failure cont<strong>ro</strong>l panel. Wall mounted Automatic cont<strong>ro</strong>l panel including transferswitch with thermal magnetic p<strong>ro</strong>tection (according to voltage and phase). CEA7Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com


PDF SummaryCreated : 11/09/2012 13:10Author : HimoinsaNumber of pages : 15Report Type: Data Sheet - Industrial rangeGenerated by: HIMOINSA Engineering Dept.Page 1. Genset dataPage 2. Engine SpecificationsPage 3. Generator SpecificationsPage 4. Cont<strong>ro</strong>l Panels models + General DescriptionPage 5. Cont<strong>ro</strong>l box and power, CE7 Panel, AlarmsPage 6. Cont<strong>ro</strong>ller features (I)Page 7. Cont<strong>ro</strong>ller features (II)Page 8. Generator Features & OptionsPage 9. Generator Features & OptionsPage 10. Installation DataPage 11. DimensionsPage 12. Another measures/dimensions of available versionsPage 13. Cont<strong>ro</strong>l Panel <st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>Page 14. Cont<strong>ro</strong>l Panel <st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>Page 15. PDF Summary (ID454E333837363231)http://www.himoinsa.com/P<strong>ro</strong>ductDetail/ficha.aspx?id=38<st<strong>ro</strong>ng>Model</st<strong>ro</strong>ng>: <st<strong>ro</strong>ng>HFW</st<strong>ro</strong>ng>-<st<strong>ro</strong>ng>135</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>T5</st<strong>ro</strong>ng>INDUSTRIAL RANGESoundp<strong>ro</strong>ofPowered by FPT_IVECOCtra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!