12.07.2015 Views

Libraries for Building Automation Function Block ... - Wago

Libraries for Building Automation Function Block ... - Wago

Libraries for Building Automation Function Block ... - Wago

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Anti-Legionnaire's Disease <strong>Function</strong> (FbAntiLegionella)Anti-Legionnaire's Disease <strong>Function</strong> (FbAntiLegionella)WAGO-I/O-PRO Library ElementsCategory:<strong>Building</strong> <strong>Automation</strong>Name:FbAntiLegionellaType: <strong>Function</strong> <strong>Function</strong> block X ProgramName of library:<strong>Building</strong>_HVAC_03.libApplicable to:See Release NoteInput parameters: Data type: Comment:xManual BOOL Manual mode, Domestic Hot Waterpreparation (DHW)xAuto BOOL Automatic mode <strong>for</strong> DHW preparationxSwitchOnDHWPreparationBOOL Enable <strong>for</strong> DHW conditioning by timerprogramrUpperStorageTankTemperaturerLowerStorageTankTemperatureREALREALUpper storage tank temperature sensor[°C]Lower storage tank temperature sensor[°C]xEnableAntiLegionella BOOL Enable <strong>for</strong> anti-Legionnaires' diseasefunctionxSwitchOnAntiLegionella BOOL Activation of anti-Legionnaires' diseasefunction by timer programtypConfigAntiLegionella Configuration parameters:.rReferenceTemperatureDHW.rReferenceTemperatureAntiLegionellaREALREALDHW reference temperature value [°C]Default setting = 50Reference value <strong>for</strong> DHW while anti-Legionnaires' disease function is active[°C]Default setting = 70.tDurationAntiLegionella TIME Duration of anti-Legionnaires' diseasefunctionDefault setting = t#10 m.rHysteresis REAL Hysteresis <strong>for</strong> the limits [K]Default setting = 2.5.xEnableAntiLegionella BOOL Enable <strong>for</strong> the Anti-Legionnaire's DiseasefunctionDefault setting = FALSExQuit BOOL Acknowledgement of the anti-Legionnaires' disease alarmReturn value:rReferenceDHWTemperatureData type: Comment:REAL DHW reference value <strong>for</strong> the DHWcontroller [°C]xDHWPreparation BOOL Enable <strong>for</strong> DHW controllerxAntiLegionella BOOL Anti-Legionnaires' disease function isactivexLegionellaAlarm BOOL Anti-Legionnaires' disease alarmSubject to design changes WAGO Kontakttechnik GmbH & Co. KG P:O. box 2880 • D-32385 Minden Phone: 05 71 / 8 87-0 E-Mail: info@wago.comCopyright © 2013 Hansastr. 27 • D-32423 Minden Fax.: +49 (0) 5 71 / 8 87-169 Web: http://www.wago.com129

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!