<strong>Smoke</strong> <strong>Shaft</strong> <strong>Ventilation</strong> <strong>System</strong>Control OptionsControl Mode 5 – 2P PTC and Control Mode 6 – 2P PTCM5-2P PTC 24V 12W (18VA), end switches SPDT 250V 6(3)A XNNN00296M6-2P PTC 230V 8W (15VA), end switches SPDT 250V 6(3)A XNNN00297Control Mode 5 – 2PDrive Open / Drive Closed. 60seconds operationThis 2 position control mode has beendeveloped to provide drive open/driveclosed damper operation and it brings<strong>Actionair</strong> dampers in line with imminentEuropean Standardisation for fire andsmoke control, where for a given smokecontrol philosophy, or smoke source, adamper may be required to open or closeto vent or contain the smoke. This is aradical alternative to the traditional springreturn actuator, where upon power failure,instead of moving to fail-safe position, itremains in its desired emergency position.For any smoke control emergencysituation, this is an absolute necessity.These modes do not have ETRs.As with all PTC actuators, this series usesthe snaplock interface. All modes haveLSF cables.Versions are available combined withprotective enclosures (Hot/Shield) toprovide further protection for 60 mins at300 °C or 30 mins at 600 °C.A.C./D.C.24V50 / 60 Hz18 V A(12W / 0.5W)Imax 8.3A@ 5ms–30... +50 CCONTINUOUSA.C.250V6(3)AM1231234–++SUPPLY 24V A.C. or D.C.2 WIRE CONTROL.CONTACT MADE BETWEEN 1 AND 2 WHEN DAMPERFULLY RELEASEDCONTACT MADE BETWEEN 4 AND 6 WHEN DAMPERFULLY RESETControl Mode 6 – 2PA.C. 230V50 / 60 Hz15 VA(8W / 0.5W)M1 N2312L2L1SUPPLY 230V A.C. 50/60Hz.2 WIRE CONTROL.CONTACT MADE BETWEEN 1 AND 2 WHEN DAMPERFULLY RELEASED– 30... +50 CCONTINUOUS34CONTACT MADE BETWEEN 4 AND 6 WHEN DAMPERFULLY RESETDamper Release and Indication ModuleDamper Release and IndicationModule (DRIM)This is designed for control and monitoringof the electrically operated A-60 MarineFire Dampers.It will operate from 24, 120 or 230 voltsupplies, 50 or 60 Hz.Selection of the operating voltage is byuse of internal links on the PCB, prior toinstallation and connection of actuatorand supply.The DRIM may be used singly to providelocal damper control, or in pairs to providecontrol from either side of a damper. It canalso operate 2 actuators when dampersare provided in 2 multiple sectionsLED position and operation indication isprovided.Operation is by push button to close andtwist to re-open damper.Tested to BS EN 61010 -1: 2001 and isCE compliant.IP44 rated.Operating range 5 - 40 degrees C.www.actionair.co.uk5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!