<strong>Smoke</strong> <strong>Shaft</strong> <strong>Ventilation</strong> <strong>System</strong>Control OptionsControl Mode 5 – 2P PTC and Control Mode 6 – 2P PTCM5-2P PTC 24V 12W (18VA), end switches SPDT 250V 6(3)A XNNN00296M6-2P PTC 230V 8W (15VA), end switches SPDT 250V 6(3)A XNNN00297Control Mode 5 – 2PDrive Open / Drive Closed. 60seconds operationThis 2 position control mode has beendeveloped to provide drive open/driveclosed damper operation and it brings<strong>Actionair</strong> dampers in line with imminentEuropean Standardisation for fire andsmoke control, where for a given smokecontrol philosophy, or smoke source, adamper may be required to open or closeto vent or contain the smoke. This is aradical alternative to the traditional springreturn actuator, where upon power failure,instead of moving to fail-safe position, itremains in its desired emergency position.For any smoke control emergencysituation, this is an absolute necessity.These modes do not have ETRs.As with all PTC actuators, this series usesthe snaplock interface. All modes haveLSF cables.Versions are available combined withprotective enclosures (Hot/Shield) toprovide further protection for 60 mins at300 °C or 30 mins at 600 °C.A.C./D.C.24V50 / 60 Hz18 V A(12W / 0.5W)Imax 8.3A@ 5ms–30... +50 CCONTINUOUSA.C.250V6(3)AM1231234–++SUPPLY 24V A.C. or D.C.2 WIRE CONTROL.CONTACT MADE BETWEEN 1 AND 2 WHEN DAMPERFULLY RELEASEDCONTACT MADE BETWEEN 4 AND 6 WHEN DAMPERFULLY RESETControl Mode 6 – 2PA.C. 230V50 / 60 Hz15 VA(8W / 0.5W)M1 N2312L2L1SUPPLY 230V A.C. 50/60Hz.2 WIRE CONTROL.CONTACT MADE BETWEEN 1 AND 2 WHEN DAMPERFULLY RELEASED– 30... +50 CCONTINUOUS34CONTACT MADE BETWEEN 4 AND 6 WHEN DAMPERFULLY RESETDamper Release and Indication ModuleDamper Release and IndicationModule (DRIM)This is designed for control and monitoringof the electrically operated A-60 MarineFire Dampers.It will operate from 24, 120 or 230 voltsupplies, 50 or 60 Hz.Selection of the operating voltage is byuse of internal links on the PCB, prior toinstallation and connection of actuatorand supply.The DRIM may be used singly to providelocal damper control, or in pairs to providecontrol from either side of a damper. It canalso operate 2 actuators when dampersare provided in 2 multiple sectionsLED position and operation indication isprovided.Operation is by push button to close andtwist to re-open damper.Tested to BS EN 61010 -1: 2001 and isCE compliant.IP44 rated.Operating range 5 - 40 degrees C.www.actionair.co.uk5


<strong>Smoke</strong> <strong>Shaft</strong> <strong>Ventilation</strong> <strong>System</strong>AccessoriesElectricalA range of indicator panels, push button switches and damper test units are also available. The housing for these units aremanufactured in rigid ABS plastic. The Damper Connection Box is in galvanised steel.DTU24 24V AC/DC XNNN00010Damper Test UnitReset and release indication.Spring bias (power OFF) test switch.Power normally ON.DTU120 120V AC XNNN00305DTU230 230V AC DNNN00029DSI24 24V AC/DC DPNN00412Damper Status IndicatorReset and release indication.DSI120 120V AC XNNN00308DSI230 230V AC DPNN00413DCU24 24V AC/DC XNNN00309Damper Control UnitSwitch ON/OFF function.Reset and release indication.DCU120 120V AC XNNN00310DCU230 230V AC XNNN00311Damper Release and IndicationModule (DRIM)Control and monitoring of theelectrically operated <strong>Smoke</strong>/ShieldPTC Fire and <strong>Smoke</strong> dampers.DRIM 24V – 230V AC/DC XNNN00589M5 and M6 – 2P Damper Control UnitSwitches power and open/closed.Open and closed indication.M52PDCU 24V AC/DC XNNN00313M62PDCU 230V AC XNNN00314Damper Connection Box(All Voltages).DCB 24V – 230V AC/DC XNNN003126 www.actionair.co.uk


<strong>Smoke</strong> <strong>Shaft</strong> <strong>Ventilation</strong> <strong>System</strong>Ordering InformationDamper ExampleQuantity Series Outer Sleeve Structural Opening Control Mode3 SSV1501/PTC F 1000 x 2000 M5 - 2PNumber ofunits requiredSSV1501/PTC / F<strong>Smoke</strong>/<strong>Shaft</strong> VentSquare or rectangular withperipheral sleeve with flangereturn.SSV1501/PTC / S<strong>Smoke</strong>/<strong>Shaft</strong> VentSquare or rectangular withperipheral sleeve.F – FlangedS – SleevedWidth x HeightRefer to page 3and 4 forminimum andmaximumopening sizes.60 Seconds Drive Open/DriveClosedMode 5-2P Open/CloseElectrical 24 Volt A.C. or D.C.XNNN00503Mode 6-2P Open/CloseElectrical 230 Volt A.C.XNNN00504Spring Return OperationFail OpenMode 5 Remote ResetElectrical 24 Volt A.C. and D.C.XNNN00481Note: Fire rated versions also available - Fail Safe Closed.Mode 6 Remote ResetElectrical 230 Volt A.C.XNNN00482Grille Example (Note: Grille type selection by customer. Grille size will be selected by <strong>Actionair</strong>)Quantity Flange Style Model Screw Fixing Paint Finish Structural Opening3 44W ECG F1 3 988 x 1988Numberof unitsrequired25W – 25mm flatsurface flangehaving mitred andwelded corners.44W – 44mm wideflat surface flangehaving mitred andwelded corners.Egg Crate GrilleECGEgg crate grille with a fixedcore.Bar GrillesGN0GNarrow blade bar grillehaving 0° deflection,3.5mm blade on 19mmpitch.GN15GNarrow blade bar grillehaving 15° deflection,3.5mm blade on 19mmpitch.F0 – No fixing(fixing by others).F1 - CountersunkScrew Holes inFlange (Standard).2 – Silver (RAL9006) stoveenamel paint. (Standard).3 – White (RAL9010) 20%gloss stove enamel paint.(Standard).6 – Special stove enamelpaint finish. (Please stateseparately the RAL colourreference and finish typerequired).Note: Extra Cost8 – Polyester powder coatfinish is available.Note: Extra CostWidth x HeightGN30GNarrow blade bar grillehaving 30° deflection,3.5mm blade on 19mmpitch.For further application, technical andpricing information, please refer to<strong>Actionair</strong> Sales Office.www.actionair.co.uk7


<strong>Smoke</strong> <strong>Shaft</strong> <strong>Ventilation</strong> <strong>System</strong>Acoustic DataThe data presented is from the LaboratoryDetermination of Acoustic andAerodynamic Performance of <strong>Smoke</strong><strong>Shaft</strong> <strong>Ventilation</strong> <strong>System</strong> (Series SSV)Automatic <strong>Smoke</strong> Release Dampers.A programme of extensive tests wascarried out in the Reverberation Chamberand North Transmission Chamber ofSound Research Laboratories Limited,Holbrook Hall, Sudbury, Suffolk, generallyin accordance with BRITISH STANDARDSNos. 4196, 4773, 4856, 4857 and 4954.This independent test facility is approvedunder the NAMAS Scheme.From the selection of a duct velocitywithin the operational parameters of thedamper a resultant pressure drop fromGraph 1 can be determined and the sumof these two components applied to theVelocity x Pressure Drop Vs Sound PowerLevel Graph. (Graph 2)The graph is the result of a full range ofacoustic tests on SSV <strong>Smoke</strong> ReleaseDampers with the blades set in their fullyopen position.The Spectrum Correction Data is appliedto the number obtained from the graphand a complete Sound Spectrum of FlowGenerated Noise for both Outlet (in duct)and Breakout (casing radiated) can beobtained from Table 1.Pressure Drop Vs VelocityGraph 1PRESSURE DROP (Pa)10090807060504030EXAMPLE LINE20109876543TYPE SSV211 2 3 4 5 6 7 8 9 10 15VELOCITY (m/s)8 www.actionair.co.uk


<strong>Smoke</strong> <strong>Shaft</strong> <strong>Ventilation</strong> <strong>System</strong>Velocity (m/s) X Pressure Drop (Pa)Vs Sound Power Level (dBW)Graph 29080Damper LeakageGraph 3SSV PTC closed blade leakage as testedon a damper 1000mm wide x 1000mm high.Leakage data at ambient temperature (Cold <strong>Smoke</strong>).1500SOUND POWER LEVEL (dBW)70605040302010010EXAMPLE LINE2030405060708090100SSV BREAKOUT200300SSV OUTLET (INDUCT)40050060070080090010002000300040005000600070008000900010000PRESSURE DIFFERENTIAL ACROSS CLOSED DAMPER (Pa)12001000500300250200150120100VELOCITY X PRESSURE DROP (m/s Pa)70Correction TablesTable 1SSV PTC Outlet (Induct) Spectrum CorrectionsOctave Band Hz 63 125 250 500 1k 2k 4k 8kSeries SSV dB 5 4 5 5 3 1 –3 –5505 10 20 30 40 50 100LEAKAGE (I/s)Table 2SSV PTC Breakout Spectrum CorrectionsOctave Band Hz 63 125 250 500 1k 2k 4k 8kSeries SSV dB 8 11 9 6 –3 –6 –14 –17www.actionair.co.uk9


<strong>Smoke</strong> <strong>Shaft</strong> <strong>Ventilation</strong> <strong>System</strong>Actionpac Damper Control <strong>System</strong>sElectro Mechanical <strong>System</strong>sActionpac EMS - Standard Control andMonitoring <strong>System</strong>Control and monitoring of Mode 5 orMode 6 damper actuators in groups of12, 24 or 36.Actionpac EMB - Bespoke Control andMonitoring <strong>System</strong> Control PanelThe EMB Control Panels typically consistsof the appropriate number of switches toprovide individual or group control, LEDindication for status monitoring and allnecessary relays and timers to complywith the customer needs for fully or semiautomatic damper operation. The EMBpanels are purposely manufactured forany particular project to suit specific clientrequirements.Actionpac EMBAddressable <strong>System</strong>sActionpac 60/120 ( LNS Standard)Intelligent Damper Control andMonitoring <strong>System</strong>Actionpac 60 for the control/monitoringof up to 60 off SSV dampers.Actionpac 120 for the control/monitoringof up to 120 off SSV dampers.Actionpac LNS3 Intelligent DamperControl and Monitoring <strong>System</strong>The Actionpac LNS3 system represents anew generation of smoke/fire dampercontrol. The system has been designedwith the user in mind, providing anadvanced tool that simplifies installationand commissioning of smoke/firedampers and peripheral devices. ThePanel PC operates on a Windowsplatform making it universally acceptedand utilises solid state technology foroptimum reliability.It’s server architecture delivers newbenefits such as reduced commissioningtime, simplified operation and scope forfuture growth.The Actionpac LNS3 system is designedto protect life and property from damagecaused by smoke and fire, by providingthe means to:–• Compartmentalise fire zones.• Reduce the spread of smoke and fire.• Keep escape routes and fire-fightingaccess open.• Allow pressurisation and smoke extractby combined operation of dampersand fans.Benefits• Completely flexible to meet practicallyany building’s damper requirements• Three levels of alarm priority• Panel PC driven system with real-timegraphic displays• Panel PC utilises solid state technologyfor optimum reliability• Full configuration and diagnostics fromPanel PC• Optional automatic scheduled Dampertesting• Multiple wiring configurations to includeRadial or Loop Topology• Damper operational count provided• Flexibility to accommodate any lastminute changes to strategy, zones,damper quantities, references anddescriptions etc.• Powerful and flexible functionalityenables standardisation of software (nobespoke site specific versions required)• Cause and effect scenarios easilyaccommodated• Multiple options for monitoringdampers, individually or by group orzone - output contacts can betriggered when a predefinedpercentage within a group or zonechange position• <strong>System</strong> designed to cater forenvironmental occupancy as well asthe building’s smoke/fire strategy.RS232 BMS link provided enabling aBMS to link directly to the system toread damper positions etc.• Optional remote access available• Graphical User Interface displays livedamper status and details as well ascause and effect strategies• Text fields facilitate clear description ofdevice references and locations• <strong>System</strong> wide activity logged andviewable for diagnostics andmaintenance• Allows for phased commissioning andfuture expansion• CE marked, LVD and EMC compliantActionpac LNS3 Intelligent Damper Controland Monitoring <strong>System</strong>Fully comprehensive brochures are available on all Actionpac products. Visit the<strong>Actionair</strong> website w.w.w.actionair.co.uk and download the relevant pdf.10 www.actionair.co.uk


<strong>Smoke</strong> <strong>Shaft</strong> <strong>Ventilation</strong> <strong>System</strong>General Schematic of Actionpac LNS3 Damper Control <strong>System</strong>To additionaldevices as requiredTo additionaldevices as required24/230 volt(local powerby others)SFDISFDI<strong>Smoke</strong> Fire Damper InterfaceOne per Control ModeSFDI24/230 volt(local powerby others)Damper Control Mode*24/230 volt(local powerby others)SFDINDI404Network Digital Input / OutputDevice - provides fourinputs and four outputsOne SFDI required per Damper/Section.Supply to each Damper Interface fromnearest local distribution board.SFDI24/230 volt(local powerby others)24/230 volt(local powerby others)SFDISFDI24/230 volt(local powerby others)SFDI24/230 volt(local powerby others)NDI40424/230 volt(local powerby others)Data NetworkPanel PCVent PanelB.M.S.OUTPUTSINPUTSFire Alarm InputsBMS InputsFireman’s Switch InputsFor further application, technical and pricing information, please refer to <strong>Actionair</strong> Sales Office.www.actionair.co.uk11


<strong>Smoke</strong> <strong>Shaft</strong> <strong>Ventilation</strong> <strong>System</strong>Ruskin Air Management Limitedis a ISO 9001 and 14001 registeredcompany.The statements made in this brochure or by ourrepresentatives in consequence of any enquiriesarising out of this document are given for informationpurposes only. They are not intended to have anylegal effect and the company is not to be regardedas bound thereby. The company will only acceptobligations which are expressly negotiated for andagreed and incorporated into a written agreementmade with its customers.Due to a policy of continuous product developmentthe specification and details contained herein aresubject to alteration without prior notice.Comprehensive and detailed informationis available for all <strong>Actionair</strong> products.Visit our website at www.actionair.co.ukRuskin Air Management LimitedSouth Street, Whitstable, KentCT5 3DU England.Tel: 01227 276100Fax: 01227 264262Email: sales@actionair.co.ukWebsite: www.actionair.co.ukBROCHURE PRODUCTION www.geoffstrange.co.uk (LNNN)