.FTWIC-2235June 2009B. Use laminated three-ply engraved plastic nameplates with black surface and whiteinterior core, at least 1/16" inch thick. Engraved lettering shall be condensed gothic atleast 1/4" inch high and properly spaced for legible and easy reading. Attach plates toequipment with chromium plate screws. Adhesive attachment is not acceptable. Identifythe following items with engraved nameplates, located as follows:1. Each switch/fuse unit or circuit breaker in each main panel and each distributionpanel - adjacent to switch/fuse unit or circuit.2. Spares shall be labeled "Spare".3. Each branch circuit panel - on panel trim cover immediately above panel door.4. Each safety disconnect switch, relay cabinet, time clock, lighting contactor - onoutside of cover.5. Each exhaust fan switch - custom engraved on outside of switch cover plate (highand low if required).6. Each motor starter - on outside cover.7. Each motor starter in motor control center on outside of switch cover.8. Outside light switches - custom engraved on outside of switch cover plate.9. Transformers - on front as near to the top as is practicalC. Branch circuit panelboard directories shall be completely and properly typewritten.Cover with plastic and attach to the inside of the cabinet door. Spares shall be labeled as"Spare".D. Refer to Section 16120, 600 VOLT WIRES AND CABLES for conductor codingrequirements.E. Refer to Section 01080, IDENTIFICATION OF SYSTEMS for junction boxidentification and codins.F. Install special custom engraved switch cover plates with engraving on the outside of thecover plate at outside light switches, and at any switch for equipment which is out ofsight from the control point.3.06 LOCKING OF ELECTRICAL FACILITIES:Install locks immediately upon the installation of the electrical facility. Provide padlocks forexterior electrical facilities subject to unauthorized entry. All padlocks shall be keyed alike.Furnish the Owner with two (2) keys per lock up to a quantity of ten (10) keys.3.07 ACCESS DOORS:A. Wherever access is required in walls, ceilings, or soffits to concealed junction boxes, pullboxes or other electrical equipment, provide and install access doors. Install panels inlocations approved by the Engineer. Paint to match surrounding surfaces.B. Refer to Section 08305, ACCESS DOORS for access door requirements.16010-10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!